/ Perfect Welding / Solar Energy / Perfect Charging
FRONIUS IG PLUS ADVANCED WITH
INTEGRATED AFCI
/ MIX Technology
/ Smart Transformer
Switching
/ Arc Fault Circuit
Interruption
/ Quick Service
Technology
/ Smart Grid
Ready
/ Wi-Fi®* Interface
/ The Fronius IG Plus Advanced was the first complete inverter lineup of NEC 2011 compliant, AFCI protected,
inverters in the United States and continues to be the leader in quality inverter technology. Power classes ranging
from 3 to 12 kW in both single and true 3 phase applications with integrated Fronius MIX Technology and wide
voltage windows are the perfect match for your system design.
TECHNICAL DATA: FRONIUS IG PLUS ADVANCED
INPUT DATA 3.0-1
Recommended PV-Power (kWp) 2.50 - 3.45 3.20 - 4.40 4.25 - 5.75 5.10 - 6.90 6.35 - 8.60 8.50 - 11.50 8.50 - 11.50 9.70 - 13.10 9.70 - 13.10 10.20 - 13.80
Nominal Input Current 8.3 A 10.5 A 13.8 A 16.5 A 20.7 A 27.6 A 27. 6 A 31.4 A 31.4 A 33.1 A
Max. Usable I nput Current 14.0 A 17. 8 A 23.4 A 28.1 A 35.1 A 46.7 A 46.7 A 53.3 A 53.3 A 56.1 A
MPPT - Voltage Range 230 - 500 V
DC Star tup 260 V
Max. Input Voltage 600 V
Admissable Conductor Size (DC) No. 14 to 6 AWG. For larger wire, use Fronius con necting distr ibutor.
Max. Current per DC Input Terminal 20 Amps. For higher input cur rent, use Fronius connec ting distributor.
OUTPUT DATA 3.0-1
Nominal Output Power 3,000 W 3,800 W 5,000 W 6,000 W 7, 5 0 0 W 9,995 W 9,995 W 11,40 0 W 11,4 00 W 12,000 W
Max. Continuous Output Power 3,000 W 3,800 W 5,000 W 6,000 W 7, 500 W 9,995 W 9,995 W 11,40 0 W 11,4 00 W 12,000 W
AC Output Voltage 208/240/277 208/240 208/240/277 208/240 480/277 W YE
Number of Phases 1 3 1 3
Admissible Conductor Size (AC) No. 14 - 4 AWG
Max. Continuous Uti lity Backfeed Cur rent 0A
Nominal Output Frequency 60 Hz
Operating Frequency Ra nge 59.3 - 60.5 Hz
Total Harmonic Distortion < 3 %
Power Factor 0.85 – 1 ind. / cap.
Operating AC Voltage Range 208 V 183 - 229 V (-12 / +10 %)
240 V 211 - 269 V (-12 / +10 %)
277 V 244 - 305 V (-12 / +10%)
Max. Continuous Output Current 208 V 14.4 A 18. 3 A 24.0 A 28.8 A 36.1 A 48.1 A 27.7 A* 54.8 A 31.6 A* n.a.
240 V 12.5 A 15 .8 A 20.8 A 25.0 A 31.3 A 41. 7 A 24. 0 A* 47. 5 A 27.4 A* n.a.
277 V 10. 8 A 13.7 A 18.1 A 21.7 A 27.1 A 36.1 A n.a. 41. 2 A n.a. 14.4 A*
*Pre phase
*The term Wi-Fi® is a registered trademark of the Wi-Fi Alliance.
3.8-1
UNI
3.8-1
UNI
5.0-1
UNI
5.0-1
UNI
6.0-1
UNI
6.0-1
UNI
7.5-1
UNI
7.5-1
UNI
10.0-1
UNI
10.0-1
UNI
UNI
UNI
10.0-3
10.0-3
DELTA
DELTA
11.4-1
11.4-1
UNI
UNI
11.4-3
11.4-3
DELTA
DELTA
12.0-3
12.0-3
WYE277
WYE277

TECHNICAL DATA: FRONIUS IG PLUS ADVANCED
GENERAL DATA 3.0-1
Max. Efficiency 96.2%
Unit Dimension s (W x H x D) 17.1 x 24.8 x 9.6 in. 17.1 x 36.4 x 9.6 in. 17.1 x 48.1 x 9.6 in.
CEC Efficiency 208 V 95.0 % 95.0 % 95.5 % 95.5 % 95.0 % 95.0 % 95.5 % 95.5 % 95.0 % n.a.
240 V 95.5 % 95.5 % 95.5 % 96.0 % 95.5 % 95.5 % 95.5 % 96.0 % 96.0 % n.a.
277 V 95.5 % 95.5 % 96.0 % 96.0 % 96.0 % 96.0 % n.a. 96.0 % n.a. 96.0 %
Consumption in Standby (Night) < 1.5 W
Consumption During Operation 8 W 15 W 20 W
Cooling Controlled forced ventilat ion, variable speed fa n
Enclosure Type NEMA 3R
Power Stack Weight 31 lbs. (14 kg) 57 lbs. (26 kg) 84 lbs. (38 kg)
Wiring Compartment Weight 24 lbs. (11 kg) 26 lbs. (12 kg)
Admissable Ambient Operating Temperature -40o F...+131o F (-40o C...+55o C)
Advanced Grid Features Active and reactive power control, low voltage ride-through
Compliance
UL 1741-2010, IEEE 1547-2003, IEEE 1547.1, UL 1699B-2013, ANSI/ IEEE C62.41, FCC Par t 15 A & B, NEC Ar ticle 690, C22. 2 No.
107.1-01 (Sept. 2011) California Sola r Initiative - Program Handbook - Appendi x C: Inverter Integral 5% Meter Performance Specifica-
PROTECTIVE EQUIPMENT 3.0-1
Ground Fault Protection Internal GFDI (Ground Fault Detector/Interrupter) in accordance with UL 1741-2010 and NEC Art. 690
DC Reverse Pola rity Protection Interna l Diode
Islanding Protection Internal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC
Over Temperature Protection Output power derating / active cooling
Arc-Fault Circuit Protection
Internal AFCI (Arc-Fault Circuit Interrupter); in accorda nce with U L 1699 Outline of Invest igation for Photovolta ic (PV) DC Arc-Fault
3.8-1
UNI
3.8-1
UNI
5.0-1
UNI
5.0-1
UNI
6.0-1
UNI
6.0-1
UNI
Circuit Protection (Issue Number 2 , Januar y 14, 2013)
7.5-1
UNI
7.5-1
UNI
10.0-1
UNI
UNI
tion
10.0-1
UNI
UNI
10.0-3
10.0-3
DELTA
DELTA
11.4-1
11.4-1
UNI
UNI
11.4-3
11.4-3
DELTA
DELTA
12.0-3
12.0-3
WYE277
WYE277
/ Perfect Welding / Solar Energy / Perfect Charging
WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF POSSIBILITY.
/ Whether welding technology, photovoltaics or battery charging technology − our goal is clearly defined: to be the innovation leader. With around
3,000 employees worldwide, we shift the limits of what’s possible - our more than 850 active patents are testimony to this. While others progress
step by step, we innovate in leaps and bounds. Just as we’ve always done. The responsible use of our resources forms the basis of our corporate policy.
Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com
v02 Feb 2014 EN
Fronius USA LLC
6797 Fronius Drive
Portage, IN 46368
USA
pv-support-usa@fronius.com
www.fronius-usa.com
Text and images c orrespond to t he current state of techn ology at th e time of print ing. Subject to m odifica tions.
All info rmation is w ithout gu arantee i n spite of caref ul editi ng - liabil ity excluded . Copyright © 2011 Fronius™. All right s reserve d.