Fronius prints on elemental chlorine free paper (ECF) sourced from certified sustainable forests (FSC).
/ Perfect Charging / Perfect Welding / Solar Energy
FK 6000
FK 6000 Pipe
FK 6000 - 400 V
Operating instructions
EN
Cooling unit
42,0426,0018,EN 010-02062021
Contents
Safety rules5
Explanation of safety notices5
General5
Proper use5
Environmental conditions6
Obligations of the operator6
Obligations of personnel6
Mains connection6
Protecting yourself and others7
Noise emission values7
Danger from toxic gases and vapours8
Danger from flying sparks8
Risks from mains current and welding current9
Meandering welding currents10
EMC Device Classifications10
EMC measures10
EMF measures11
Specific hazards11
Requirement for the shielding gas12
Danger from shielding gas cylinders12
Danger from escaping shielding gas13
Safety measures at the installation location and during transport13
Safety measures in normal operation13
Commissioning, maintenance and repair14
Safety inspection14
Disposal15
Safety symbols15
Data protection15
Copyright15
General16
Appliance concept16
Areas of utilisation16
Information about the coolant16
Custom versions16
Start-up18
General remarks18
Guarantee provisions regarding the coolant pump18
Information on the coolant18
Filling / topping up the reservoir with coolant18
Purge cooling unit18
Start operation of cooling unit 19
Changing the welding torch19
Control elements and connections20
Safety20
Front20
Rear21
Possible configurations22
Safety22
Standard configuration using interconnecting hosepack or connection hoses22
Connecting in series using interconnecting hosepack23
Connecting in series using connection hoses23
Before commissioning25
Safety25
Utilisation for intended purpose only25
Setup regulations25
Mains connection26
Mains voltage of FK 600026
Setting the mains voltage of FK 6000 Pipe27
Setting the mains voltage of FK 6000 - 400 V27
Care, maintenance and disposal28
EN
3
General remarks28
Safety28
Symbols for care and maintenance of the cooling unit28
Every start-up28
Every week29
Every 2 months29
Every 6 months29
Every 12 months29
Applicability of the “General Terms of Delivery and Payment”29
Disposal30
Troubleshooting31
Safety31
Troubleshooting31
Technical data33
General remarks33
FK 600033
FK 6000 Pipe34
FK 6000 - 400 V35
4
Safety rules
EN
Explanation of
safety notices
DANGER!
Indicates immediate danger.
If not avoided, death or serious injury will result.
▶
WARNING!
Indicates a potentially hazardous situation.
If not avoided, death or serious injury may result.
▶
CAUTION!
Indicates a situation where damage or injury could occur.
If not avoided, minor injury and/or damage to property may result.
▶
NOTE!
Indicates a risk of flawed results and possible damage to the equipment.
GeneralThe device is manufactured using state-of-the-art technology and according to recog-
nised safety standards. If used incorrectly or misused, however, it can cause:
-injury or death to the operator or a third party,
-damage to the device and other material assets belonging to the operating company,
-inefficient operation of the device.
All persons involved in commissioning, operating, maintaining and servicing the device
must:
-be suitably qualified,
-have sufficient knowledge of welding and
-read and follow these operating instructions carefully.
The operating instructions must always be at hand wherever the device is being used. In
addition to the operating instructions, attention must also be paid to any generally applicable and local regulations regarding accident prevention and environmental protection.
All safety and danger notices on the device
-must be in a legible state,
-must not be damaged,
-must not be removed,
-must not be covered, pasted or painted over.
For the location of the safety and danger notices on the device, refer to the section
headed "General" in the operating instructions for the device.
Before switching on the device, rectify any faults that could compromise safety.
This is for your personal safety!
Proper useThe device is to be used exclusively for its intended purpose.
5
The device is intended solely for the welding processes specified on the rating plate.
Any use above and beyond this purpose is deemed improper. The manufacturer shall not
be held liable for any damage arising from such usage.
Proper use includes:
-carefully reading and following all the instructions given in the operating instructions
-studying and obeying all safety and danger notices carefully
-performing all stipulated inspection and maintenance work.
Never use the device for the following purposes:
-Thawing out pipes
-Charging batteries
-Starting engines
The device is designed for use in industry and the workshop. The manufacturer accepts
no responsibility for any damage caused through use in a domestic setting.
The manufacturer likewise accepts no liability for inadequate or incorrect results.
Environmental
conditions
Obligations of the
operator
Operation or storage of the device outside the stipulated area will be deemed as not in
accordance with the intended purpose. The manufacturer shall not be held liable for any
damage arising from such usage.
Ambient temperature range:
-during operation: -10 °C to + 40 °C (14 °F to 104 °F)
-during transport and storage: -20 °C to +55 °C (-4 °F to 131 °F)
Relative humidity:
-up to 50% at 40 °C (104 °F)
-up to 90% at 20 °C (68 °F)
The surrounding air must be free from dust, acids, corrosive gases or substances, etc.
Can be used at altitudes of up to 2000 m (6561 ft. 8.16 in.)
The operator must only allow persons to work with the device who:
-are familiar with the fundamental instructions regarding safety at work and accident
prevention and have been instructed in how to use the device
-have read and understood these operating instructions, especially the section
"safety rules", and have confirmed as much with their signatures
-are trained to produce the required results.
Checks must be carried out at regular intervals to ensure that operators are working in a
safety-conscious manner.
Obligations of
personnel
Mains connectionDevices with a higher rating may affect the energy quality of the mains due to their cur-
6
Before using the device, all persons instructed to do so undertake:
-to observe the basic instructions regarding safety at work and accident prevention
-to read these operating instructions, especially the "Safety rules" section and sign to
confirm that they have understood them and will follow them.
Before leaving the workplace, ensure that people or property cannot come to any harm
in your absence.
rent consumption.
This may affect a number device types in terms of:
-Connection restrictions
-
Criteria with regard to the maximum permissible mains impedance
-
Criteria with regard to the minimum short-circuit power requirement
*)
at the interface with the public grid
*)
*)
see "Technical data"
In this case, the plant operator or the person using the device should check whether the
device may be connected, where appropriate by discussing the matter with the power
supply company.
IMPORTANT! Ensure that the mains connection is earthed properly
EN
Protecting yourself and others
Anyone working with the device exposes themselves to numerous risks, e.g.
-flying sparks and hot pieces of metal
-Arc radiation, which can damage eyes and skin
-Hazardous electromagnetic fields, which can endanger the lives of those using cardiac pacemakers
-Risk of electrocution from mains current and welding current
-Greater noise pollution
-Harmful welding fumes and gases
Suitable protective clothing must be worn when working with the device. The protective
clothing must have the following properties:
-Flame-resistant
-Insulating and dry
-Covers the whole body, is undamaged and in good condition
-Safety helmet
-Trousers with no turn-ups
Protective clothing refers to a variety of different items. Operators should:
-Protect eyes and face from UV rays, heat and sparks using a protective visor and
regulation filter
-Wear regulation protective goggles with side protection behind the protective visor
-Wear stout footwear that provides insulation even in wet conditions
-Protect the hands with suitable gloves (electrically insulated and providing protection
against heat)
-Wear ear protection to reduce the harmful effects of noise and to prevent injury
Noise emission
values
Keep all persons, especially children, out of the working area while any devices are in
operation or welding is in progress. If, however, there are people in the vicinity:
-Make them aware of all the dangers (risk of dazzling by the arc, injury from flying
sparks, harmful welding fumes, noise, possible risks from mains current and welding
current, etc.)
The device generates a maximum sound power level of <80 dB(A) (ref. 1pW) when idling
and in the cooling phase following operation at the maximum permissible operating point
under maximum rated load conditions according to EN 60974-1.
It is not possible to provide a workplace-related emission value during welding (or cutting) as this is influenced by both the process and the environment. All manner of different welding parameters come into play, including the welding process (MIG/MAG, TIG
welding), the type of power selected (DC or AC), the power range, the type of weld
metal, the resonance characteristics of the workpiece, the workplace environment, etc.
7
Danger from
toxic gases and
vapours
The fumes produced during welding contain harmful gases and vapours.
Welding fumes contain substances that cause cancer, as stated in Monograph 118 of the
International Agency for Research on Cancer.
Use at-source extraction and a room extraction system.
If necessary, use a welding torch with an integrated extraction device.
Keep your face away from welding fumes and gases.
Fumes and hazardous gases
-must not be breathed in
-must be extracted from the working area using appropriate methods.
Ensure an adequate supply of fresh air. Ensure that there is a ventilation rate of at least
20 m³ per hour at all times.
Otherwise, a welding helmet with an air supply must be worn.
If there is any doubt about whether the extraction capacity is sufficient, the measured
toxic emission values should be compared with the permissible limit values.
The following components are responsible, amongst other things, for the degree of toxicity of welding fumes:
-Metals used for the workpiece
-Electrodes
-Coatings
-Cleaners, degreasers, etc.
-Welding process used
Danger from flying sparks
The relevant material safety data sheets and manufacturer's specifications for the listed
components should therefore be studied carefully.
Recommendations for trade fair scenarios, risk management measures and for identifying working conditions can be found on the European Welding Association website under
Health & Safety (https://european-welding.org).
Flammable vapours (e.g. solvent fumes) should be kept away from the arc's radiation
area.
Close the shielding gas cylinder valve or main gas supply if no welding is taking place.
Flying sparks may cause fires or explosions.
Never weld close to flammable materials.
Flammable materials must be at least 11 metres (36 ft. 1.07 in.) away from the arc, or
alternatively covered with an approved cover.
A suitable, tested fire extinguisher must be available and ready for use.
Sparks and pieces of hot metal may also get into adjacent areas through small gaps or
openings. Take appropriate precautions to prevent any danger of injury or fire.
Welding must not be performed in areas that are subject to fire or explosion or near
sealed tanks, vessels or pipes unless these have been prepared in accordance with the
relevant national and international standards.
Do not carry out welding on containers that are being or have been used to store gases,
propellants, mineral oils or similar products. Residues pose an explosive hazard.
8
Risks from mains
current and welding current
An electric shock is potentially life threatening and can be fatal.
Do not touch live parts either inside or outside the device.
During MIG/MAG welding and TIG welding, the welding wire, the wirespool, the feed
rollers and all pieces of metal that are in contact with the welding wire are live.
Always set the wirefeeder up on a sufficiently insulated surface or use a suitable, insulated wirefeeder holder.
Make sure that you and others are protected with an adequately insulated, dry base or
cover for the earth or ground potential. This base or cover must extend over the entire
area between the body and the earth or ground potential.
All cables and leads must be secured, undamaged, insulated and adequately dimensioned. Replace loose connections and scorched, damaged, or inadequately dimensioned cables and leads immediately.
Use the handle to ensure the power connections are tight before every use.
In the case of power cables with a bayonet connector, rotate the power cable around the
longitudinal axis by at least 180° and pretension.
Do not wrap cables or leads around the body or parts of the body.
The electrode (rod electrode, tungsten electrode, welding wire, etc.) must
-never be immersed in liquid for cooling
-Never touch the electrode when the power source is switched on.
EN
Double the open circuit voltage of a power source can occur between the welding electrodes of two power sources. Touching the potentials of both electrodes at the same time
may be fatal under certain circumstances.
Arrange for the mains cable to be checked regularly by a qualified electrician to ensure
the ground conductor is functioning properly.
Protection class I devices require a mains supply with ground conductor and a connector
system with ground conductor contact for proper operation.
Operation of the device on a mains supply without ground conductor and on a socket
without ground conductor contact is only permitted if all national regulations for protective
separation are observed.
Otherwise, this is considered gross negligence. The manufacturer shall not be held liable
for any damage arising from such usage.
If necessary, provide adequate earthing for the workpiece.
Switch off unused devices.
Wear a safety harness if working at height.
Before working on the device, switch it off and pull out the mains plug.
Attach a clearly legible and easy-to-understand warning sign to the device to prevent
anyone from plugging the mains plug back in and switching it on again.
After opening the device:
-Discharge all live components
-Ensure that all components in the device are de-energised.
If work on live parts is required, appoint a second person to switch off the main switch at
the right moment.
9
Meandering welding currents
If the following instructions are ignored, meandering welding currents can develop with
the following consequences:
-Fire hazard
-Overheating of parts connected to the workpiece
-Irreparable damage to ground conductors
-Damage to device and other electrical equipment
Ensure that the workpiece is held securely by the workpiece clamp.
Attach the workpiece clamp as close as possible to the area that is to be welded.
Position the device with sufficient insulation against electrically conductive environments,
e.g. Insulation against conductive floor or insulation to conductive racks.
If distribution boards, twin-head mounts, etc., are being used, note the following: The
electrode of the welding torch / electrode holder that is not used is also live. Make sure
that the welding torch / electrode holder that is not used is kept sufficiently insulated.
In the case of automated MIG/MAG applications, ensure that only an insulated wire electrode is routed from the welding wire drum, large wirefeeder spool or wirespool to the
wirefeeder.
EMC Device Classifications
EMC measuresIn certain cases, even though a device complies with the standard limit values for emis-
Devices in emission class A:
-Are only designed for use in industrial settings
-Can cause line-bound and radiated interference in other areas
Devices in emission class B:
-Satisfy the emissions criteria for residential and industrial areas. This is also true for
residential areas in which the energy is supplied from the public low-voltage mains.
EMC device classification as per the rating plate or technical data.
sions, it may affect the application area for which it was designed (e.g. when there is
sensitive equipment at the same location, or if the site where the device is installed is
close to either radio or television receivers).
If this is the case, then the operator is obliged to take appropriate action to rectify the
situation.
Check and evaluate the immunity to interference of nearby devices according to national
and international regulations. Examples of equipment that may be susceptible to interference from the device include:
-Safety devices
-Power, signal and data transfer lines
-IT and telecommunications devices
-Measuring and calibrating devices
10
Supporting measures for avoidance of EMC problems:
tional measures are necessary (e.g. use a suitable line filter).
2.Welding power leads
-must be kept as short as possible
-must run close together (to avoid EMF problems)
-must be kept well apart from other leads
3.Equipotential bonding
4.Earthing of the workpiece
-If necessary, establish an earth connection using suitable capacitors.
5.Shielding, if necessary
-Shield off other nearby devices
-Shield off entire welding installation
EMF measuresElectromagnetic fields may pose as yet unknown risks to health:
-effects on the health of others in the vicinity, e.g. wearers of pacemakers and hearing aids
-wearers of pacemakers must seek advice from their doctor before approaching the
device or any welding that is in progress
-for safety reasons, keep distances between the welding cables and the welder's
head/torso as large as possible
-do not carry welding cables and hosepacks over the shoulders or wind them around
any part of the body
Specific hazardsKeep hands, hair, clothing and tools away from moving parts. For example:
-Fans
-Cogs
-Rollers
-Shafts
-Wirespools and welding wires
EN
Do not reach into the rotating cogs of the wire drive or into rotating drive components.
Covers and side panels may only be opened/removed while maintenance or repair work
is being carried out.
During operation
-Ensure that all covers are closed and all side panels are fitted properly.
-Keep all covers and side panels closed.
The welding wire emerging from the welding torch poses a high risk of injury (piercing of
the hand, injuries to the face and eyes, etc.).
Therefore always keep the welding torch away from the body (devices with wire-feed
unit) and wear suitable protective goggles.
Never touch the workpiece during or after welding - risk of burns.
Slag can jump off cooling workpieces. The specified protective equipment must therefore
also be worn when reworking workpieces, and steps must be taken to ensure that other
people are also adequately protected.
Welding torches and other parts with a high operating temperature must be allowed to
cool down before handling.
Special provisions apply in areas at risk of fire or explosion - observe relevant
national and international regulations.
Power sources for work in areas with increased electric risk (e.g. near boilers) must carry
the "Safety" sign. However, the power source must not be located in such areas.
Risk of scalding from escaping coolant. Switch off cooling unit before disconnecting
coolant flow or return lines.
Observe the information on the coolant safety data sheet when handling coolant. The
coolant safety data sheet may be obtained from your service centre or downloaded from
the manufacturer's website.
Use only suitable load-carrying equipment supplied by the manufacturer when transporting devices by crane.
11
-Hook chains and/or ropes onto all suspension points provided on the load-carrying
equipment.
-Chains and ropes must be at the smallest angle possible to the vertical.
-Remove gas cylinder and wire-feed unit (MIG/MAG and TIG devices).
If the wire-feed unit is attached to a crane holder during welding, always use a suitable,
insulated wirefeeder hoisting attachment (MIG/MAG and TIG devices).
If the device has a carrying strap or handle, this is intended solely for carrying by hand.
The carrying strap is not to be used if transporting with a crane, counterbalanced lift truck
or other mechanical hoist.
All lifting accessories (straps, handles, chains, etc.) used in connection with the device or
its components must be tested regularly (e.g. for mechanical damage, corrosion or
changes caused by other environmental factors).
The testing interval and scope of testing must comply with applicable national standards
and directives as a minimum.
Odourless and colourless shielding gas may escape unnoticed if an adapter is used for
the shielding gas connection. Prior to assembly, seal the device-side thread of the
adapter for the shielding gas connection using suitable Teflon tape.
Requirement for
the shielding gas
Danger from
shielding gas cylinders
Especially with ring lines, contaminated shielding gas can cause damage to equipment
and reduce welding quality.
Meet the following requirements regarding shielding gas quality:
-Solid particle size < 40 µm
-Pressure condensation point < -20 °C
-Max. oil content < 25 mg/m³
Use filters if necessary.
Shielding gas cylinders contain gas under pressure and can explode if damaged. As the
shielding gas cylinders are part of the welding equipment, they must be handled with the
greatest of care.
Protect shielding gas cylinders containing compressed gas from excessive heat, mechanical impact, slag, naked flames, sparks and arcs.
Mount the shielding gas cylinders vertically and secure according to instructions to prevent them falling over.
Keep the shielding gas cylinders well away from any welding or other electrical circuits.
Never hang a welding torch on a shielding gas cylinder.
Never touch a shielding gas cylinder with an electrode.
12
Risk of explosion - never attempt to weld a pressurised shielding gas cylinder.
Only use shielding gas cylinders suitable for the application in hand, along with the correct and appropriate accessories (regulator, hoses and fittings). Only use shielding gas
cylinders and accessories that are in good condition.
Turn your face to one side when opening the valve of a shielding gas cylinder.
Close the shielding gas cylinder valve if no welding is taking place.
If the shielding gas cylinder is not connected, leave the valve cap in place on the cylinder.
The manufacturer's instructions must be observed as well as applicable national and
international regulations for shielding gas cylinders and accessories.
EN
Danger from
escaping shielding gas
Safety measures
at the installation
location and during transport
Risk of suffocation from the uncontrolled escape of shielding gas
Shielding gas is colourless and odourless and, in the event of a leak, can displace the
oxygen in the ambient air.
-Ensure an adequate supply of fresh air with a ventilation rate of at least 20 m³/hour.
-Observe safety and maintenance instructions on the shielding gas cylinder or the
main gas supply.
-Close the shielding gas cylinder valve or main gas supply if no welding is taking
place.
-Check the shielding gas cylinder or main gas supply for uncontrolled gas leakage
before every start-up.
A device toppling over could easily kill someone. Place the device on a solid, level surface such that it remains stable
-The maximum permissible tilt angle is 10°.
Special regulations apply in rooms at risk of fire or explosion
-Observe relevant national and international regulations.
Use internal directives and checks to ensure that the workplace environment is always
clean and clearly laid out.
Only set up and operate the device in accordance with the degree of protection shown
on the rating plate.
Safety measures
in normal operation
When setting up the device, ensure there is an all-round clearance of 0.5 m (1 ft. 7.69
in.) to ensure that cooling air can flow in and out freely.
When transporting the device, observe the relevant national and local guidelines and
accident prevention regulations. This applies especially to guidelines regarding the risks
arising during transport.
Do not lift or transport operational devices. Switch off devices before transport or lifting.
Before transporting the device, allow coolant to drain completely and detach the following components:
-Wirefeeder
-Wirespool
-Shielding gas cylinder
After transporting the device, the device must be visually inspected for damage before
commissioning. Any damage must be repaired by trained service technicians before
commissioning the device.
Only operate the device when all safety devices are fully functional. If the safety devices
are not fully functional, there is a risk of
-injury or death to the operator or a third party
-damage to the device and other material assets belonging to the operator
-inefficient operation of the device
Any safety devices that are not functioning properly must be repaired before switching on
the device.
Never bypass or disable safety devices.
13
Before switching on the device, ensure that no one is likely to be endangered.
Check the device at least once a week for obvious damage and proper functioning of
safety devices.
Always fasten the shielding gas cylinder securely and remove it beforehand if the device
is to be transported by crane.
Only the manufacturer's original coolant is suitable for use with our devices due to its
properties (electrical conductibility, anti-freeze agent, material compatibility, flammability,
etc.).
Only use suitable original coolant from the manufacturer.
Do not mix the manufacturer's original coolant with other coolants.
Only connect the manufacturer's system components to the cooling circuit.
The manufacturer accepts no liability for damage resulting from use of other system
components or a different coolant. In addition, all warranty claims will be forfeited.
Cooling Liquid FCL 10/20 does not ignite. The ethanol-based coolant can ignite under
certain conditions. Transport the coolant only in its original, sealed containers and keep
well away from any sources of ignition.
Used coolant must be disposed of properly in accordance with the relevant national and
international regulations. The coolant safety data sheet may be obtained from your service centre or downloaded from the manufacturer's website.
Check the coolant level before starting to weld, while the system is still cool.
Commissioning,
maintenance and
repair
Safety inspectionThe manufacturer recommends that a safety inspection of the device is performed at
It is impossible to guarantee that bought-in parts are designed and manufactured to meet
the demands made of them, or that they satisfy safety requirements.
-Use only original spare and wearing parts (also applies to standard parts).
-Do not carry out any modifications, alterations, etc. to the device without the manufacturer's consent.
-Components that are not in perfect condition must be replaced immediately.
-When ordering, please give the exact designation and part number as shown in the
spare parts list, as well as the serial number of your device.
The housing screws provide the ground conductor connection for earthing the housing
parts.
Only use original housing screws in the correct number and tightened to the specified
torque.
least once every 12 months.
The manufacturer recommends that the power source be calibrated during the same 12month period.
14
A safety inspection should be carried out by a qualified electrician
-after any changes are made
-after any additional parts are installed, or after any conversions
-after repair, care and maintenance has been carried out
-at least every twelve months.
For safety inspections, follow the appropriate national and international standards and
directives.
Further details on safety inspection and calibration can be obtained from your service
centre. They will provide you on request with any documents you may require.
DisposalDo not dispose of this device with normal domestic waste! To comply with the European
Directive on Waste Electrical and Electronic Equipment and its implementation as
national law, electrical equipment that has reached the end of its life must be collected
separately and returned to an approved recycling facility. Any device that you no longer
require must either be returned to your dealer or given to one of the approved collection
and recycling facilities in your area. Ignoring this European Directive may have potentially adverse affects on the environment and your health!
Safety symbolsDevices with the CE mark satisfy the essential requirements of the low-voltage and elec-
tromagnetic compatibility directives (e.g. relevant product standards of the EN 60 974
series).
Fronius International GmbH hereby declares that the device is compliant with Directive
2014/53/EU. The full text on the EU Declaration of Conformity can be found at the following address: http://www.fronius.com
Devices marked with the CSA test mark satisfy the requirements of the relevant standards for Canada and the USA.
EN
Data protectionThe user is responsible for the safekeeping of any changes made to the factory settings.
The manufacturer accepts no liability for any deleted personal settings.
CopyrightCopyright of these operating instructions remains with the manufacturer.
The text and illustrations are all technically correct at the time of printing. We reserve the
right to make changes. The contents of the operating instructions shall not provide the
basis for any claims whatsoever on the part of the purchaser. If you have any suggestions for improvement, or can point out any mistakes that you have found in the instructions, we will be most grateful for your comments.
15
General
Appliance
concept
Areas of utilisation
The FK 6000 cooling unit is a “use-anywhere” cooling unit with suitability for all
welding processes at the high end of the
power range. The FK 6000 can be operated independently of a power source.
When deployed directly next to the
wirefeeder, there is no need for a long
interconnecting hosepack.
The FK 6000 cooling unit is a “use-anywhere” appliance that is suitable for many different welding processes:
-Welding at high ambient temperatures
-High welding power from one power source
-Operating power sources in parallel (power sharing)
-TimeTwin Digital
-Plasma welding
-TIG welding at the high end of the power range
Information about
the coolant
Danger from using non-permitted coolant.
This can result in serious damage to property.
▶
▶
▶
▶
Custom versionsFK 6000 Pipe
The FK 6000 Pipe cooling unit is a special version of the FK 6000 that is designed for
deployment under extreme climatic conditions. The FK 6000 Pipe comes with the following additional equipment:
-Special coolant pump and delivery hoses for the low-temperature range
-Special coolant with improved thermal characteristics for low-temperature environ-
-Coolant watchdog option with connector for external signal evaluation by the robot
-Water filter
-Auto-transformer
CAUTION!
Only use coolant available from the manufacturer.
Do not mix different coolants.
When changing the coolant, make sure all the coolant is replaced.
When switching from ethanol-based coolant to FCL 10/20 coolant, Change Kit
FCL10 must be used and the instructions provided must be followed.
ments
control
16
NOTE!
Only fill or top up the reservoir of the FK 6000 Pipe cooling unit with original
Fronius Pipe coolant.
Due to their electrical conductivity and inadequate material compatibility, and to the high
thermal stresses encountered in this application, all other antifreeze agents are unsuitable for use here.
FK 6000 - 400 V
The cooling unit FK 6000 - 400V has an auto-transformer as standard and can also be
operated at following input voltages:
110 / 230 / 400 / 440 / 460 V.
EN
17
Start-up
General remarksThe cooling units are supplied “dry”, i.e. without any coolant in the reservoir. The coolant
is supplied separately, in two 5l canisters. Before using the cooling unit for the first time,
fill the reservoir with coolant!
Guarantee provisions regarding
the coolant pump
Information on
the coolant
Filling / topping
up the reservoir
with coolant
The coolant pump may only be used with original coolant supplied by the manufacturer.
Do not allow the coolant pump to run dry (even for a very short time), as this will destroy
the coolant pump. The manufacturer accepts no liability for damage caused in such
cases.
Only use original Fronius coolant for the filling of the cooling unit. Other antifreezers cannot be recommended due to their electric conductivity and compatibility.
Shift the mains switch of the power source into the “O” position
1
Unscrew the screw-cap
2
Top up the reservoir with coolant
3
Screw the cap back on again - the cooling unit is now ready for operation
4
NOTE!
After filling the reservoir of the cooling unit with coolant for the first time, you
must vent the cooling unit before starting to use it.
Purge cooling
unit
Purge the cooling unit
-after the first filling,
-if there is no coolant circulation although the cooling pump works.
Purge cooling unit:
Plug in mains plug or connect power supply
1
Switch mains switch in position “I“ - the cooling unit is ready for operation
2
Shift back safety ring on the plug-type connection of water flow - black
3
Disconnect water flow hose
4
Press in carefully and hold conical nipple in the centre of the plug-type connection of
5
the water flow by means of a wooden or plastic pin
Release conical nipple as soon as liquid penetrates
6
Reconnect water flow hose
7
Check water hoses for tightness
8
Repeat purge until proper return flow to the filler neck is ensured.
18
Start operation of
cooling unit
NOTE!
Before any start-up of the cooling unit, check the coolant level as well as the
coolant purity.
Connect supply of power source(s)
1
Switch mains switch of the power source(s) in position “I” - the cooling pump starts
2
operation.
Check coolant flow until proper flow is ensured. If necessary, deairate coolant circu-
3
lation.
NOTE!
During welding check coolant flow at regular intervals - a proper return flow must
be visible in the filler neck.
EN
Changing the
welding torch
CAUTION!
Excess pressure will damage the cooling unit.
Before blowing out the welding torch with compressed air, undo the screw cap on the fill
nozzle.
19
Control elements and connections
(1)(3)(4) (5) (6) (7) (8) (9)(2)
Safety
Front
WARNING!
Danger from incorrect operation.
Possible serious injury and damage to property.
Do not use the functions described here until you have read and completely under-
▶
stood these Operating Instructions.
Do not use the functions described here until you have fully read and understood all
▶
of the Operating Instructions for the system components, in particular the safety
rules!
(1)Coolant inspection window
(2)Rating plate
(3)Screw-cap and filler neck
(4)Important notes on maintenance
and operation
(5)Fuse for mains power supply
is tripped if the wrong mains
voltage has been set, or if overvoltage occurs
(6)Fuse for coolant pump
is tripped if the coolant pump is
overloaded or blocked
(7)Connection jack for coolant watchdog
for signal evaluation by the robot control. The signal evaluation is carried out via
pins 3 and 4 of the connection socket.
(8)Mains switch
(9)Mains cable / mains cable lead-through
20
Rear
(10)(11)
(12)
(10)Coolant forward-flow connector
(blue)
(11)Water filter
(12)Coolant return-flow connector
(red)
IMPORTANT!
Fit the filter retaining plate using the
accompanying screws and insert the
filter.
The connections are fitted with screw connections as standard. If required, attach
the plug connectors provided to the connections.
EN
21
Possible configurations
Safety
Standard configuration using
interconnecting
hosepack or connection hoses
WARNING!
An electric shock can be fatal.
If the unit is plugged into the mains electricity supply during installation, there is a high
risk of very serious injury and damage. Only carry out any work on the unit if
the mains switch is in the “O” position, and
▶
the unit is unplugged from the mains.
▶
This configuration should be used for:
-applications with one power source only
-operating power sources in parallel (power sharing)
-plasma applications
22
Standard configuration using interconnecting hosepack or connection hoses
Connecting in
series using
interconnecting
hosepack
This configuration should be used for:
-TimeTwin Digital applications where the wirefeeders are placed near the power
sources
Alternatively, a series connection is also possible using connection hoses
EN
Connecting in
series using connection hoses
Connecting in series using interconnecting hosepack
(1)Double quick-acting coupler
This configuration should be used for:
-TimeTwin Digital applications where the wirefeeders are placed near the power
sources
Alternatively, a series connection is also possible using connection hoses
23
Connecting in series using connection hoses
(1)Connecting lead
24
Before commissioning
EN
Safety
Utilisation for
intended purpose
only
WARNING!
Danger from incorrect operation.
Possible serious injury and damage to property.
Do not use the functions described here until you have read and completely under-
▶
stood these Operating Instructions.
Do not use the functions described here until you have fully read and understood all
▶
of the Operating Instructions for the system components, in particular the safety
rules!
The cooling unit may ONLY be used for cooling welding system components used in
MIG/MAG, TIG, MMA (electrode) or plasma welding.
Utilisation for any other purpose, or in any other manner, shall be deemed to be “not in
accordance with the intended purpose”. The manufacturer shall not be liable for any
damage resulting from such improper use.
Utilisation in accordance with the “intended purpose” also comprises
-following all the instructions given in this manual
-performing all stipulated inspection and servicing work.
Setup regulations
WARNING!
Danger from machines falling or toppling over.
This can result in serious injury and damage to property
Place all system components on a solid, level surface in such a way that they
▶
remain stable.
WARNING!
Danger from electric current.
An electric shock can be fatal.
Ensure the cooling unit is properly insulated.
▶
Always ensure that there is no electrically conductive connection between the base
▶
plate of the cooling unit and the surface.
Before installing the cooling unit, remove all electrically conductive parts between
▶
the base plate of the cooling unit and the surface.
The device is tested to IP 23 protection, meaning:
-Protection against penetration by solid foreign bodies with diameters > 12.5 mm
(0.49 in.)
-Protection against spraywater at any angle up to 60° to the vertical
Cooling air
The system must be set up in such a way that the cooling air can flow unimpeded
through the slots in the side panels. Ensure that there is always an all-round clearance of
0.5 m (1 ft. 7.69 in.) around the device.
25
CAUTION!
Danger from insufficient cooling air supply.
This can result in serious damage to property.
Air inlets and outlets must never be covered, not even partially.
▶
Dust
Ensure that any metallic dust, for example from grinding work, is not sucked into the system by the fan.
Outdoor operation
The device can be set up and operated outdoors in accordance with degree of protection
IP23. Avoid direct wetting (e.g. from rain).
Mains connectionThe equipment is designed to run on the mains voltage given on the respective rating
plates. If your version of the appliance does not come with the mains cables and plugs
ready-mounted, these must be mounted in accordance with your national regulations
and Standards. For details of fuse protection of the mains supply lead, please see the
Technical Data.
NOTE!
Mains voltage of
FK 6000
Inadequately dimensioned electrical installations can lead to serious damage to
(or loss of) property.
The mains supply lead, and its fuse protection, must be dimensioned accordingly. The
technical data shown on the rating plate shall apply.
CAUTION!
Running the unit on the wrong mains voltage can cause serious damage.
The mains voltage that you enter on the rating plate must be the same as the voltage
that you have just set.
IMPORTANT!
The FK 6000 cooling unit is fixed at 230
V.
It cannot be altered to any other mains
voltage.
26
FK 6000: fixed mains voltage
Setting the mains
voltage of FK
6000 Pipe
The FK 6000 Pipe cooling unit can be used with different mains voltages. The mains
voltage set at the factory is shown on the rating plate.
How to set the mains voltage:
Shift the mains switch into the “O”
1
position
Unplug or otherwise disconnect the
2
unit from the mains power supply
Open the housing
3
Connect the phase conductor (L1) to
4
the appropriate terminal for your
mains voltage
Check that all cables are fixed firmly
5
FK 6000 Pipe: Setting the mains voltage
Close the housing
6
Cross out the mains voltage originally
7
entered on the rating plate and - in the
empty box - enter the mains voltage
that you have just set
EN
Setting the mains
voltage of FK
6000 - 400 V
FK 6000 - 400 V: Setting the mains voltage
How to set the mains voltage
Shift the mains switch into the “O”
1
position
Unplug or otherwise disconnect the
2
unit from the mains power supply
Open the housing
3
Connect the phase conductor (L1) to
4
the appropriate terminal for your
mains voltage
Check that all cables are fixed firmly
5
Close the housing
6
Cross out the mains voltage originally
7
entered on the rating plate and - in the
empty box - enter the mains voltage
that you have just set.
27
Care, maintenance and disposal
(1)
(2)(3)
(4)
General remarksUnder normal operating conditions the cooling unit requires only a minimum of care and
maintenance. However, it is indispensable to follow some important points to ensure the
operationality of the welding machine for many years.
Safety
WARNING!
An electric shock can be fatal.
Before opening up the machine, switch it off, unplug it from the mains and put up a
clearly legible and easy-to-understand warning sign to stop anybody inadvertently
switching the machine back on again. The casing screws are a suitable protective conductor connection for grounding the casing. The screws must not be replaced by other
screws without reliable protective conductor connection.
CAUTION!
Danger of scalding from hot coolant fluid.
Do not inspect the coolant connection points until the coolant has been allowed to cool.
IMPORTANT!
The coolant must not be disposed of via the sewerage!
NOTE!
For refilling the cooling unit only use coolant of the manufacturer.
Symbols for care
and maintenance
of the cooling
unit
Every start-up-Check welding torch, interconnection cable assembly and bondings for damage
-Check whether the allround distance of 0.5 m (1.6 ft.) is kept to ensure that the cooling air can easily flow and escape.
(1)Check coolant level
(2)Change the coolant
(3)Gas purge the cooler
(4)Read operating instructions
The relevant maintenance intervals and
work are described in detail in the following pages.
28
NOTE!
Every week
Furthermore, air inlets and outlets must in no case be covered, not even covered
partly.
CAUTION!
Danger of scalding from hot coolant fluid.
Do not inspect the coolant connection points until the coolant has been allowed to cool.
If water-cooled welding torch is used:
-Check water connections for tightness
-Control water return flowrate in coolant container
-If there is no water return flow, check cooling unit and purge if necessary
NOTE!
If water-cooled welding torches are operated without cooling water, this mostly
causes a defect of the torch body or the hose pack.
The manufacturer does not accept responsibility for any consequential damages. Any
warranty claims expire.
Check the coolant level as well as the coolant purity.
1
If the coolant level drops below the “min“ mark ... refill coolant.
2
EN
Every 2 months
Every 6 months
Every 12 months
Applicability of
the “General
Terms of Delivery
and Payment”
Check the coolant level as well as the coolant purity.
1
If the coolant level drops below the “min“ mark ... refill coolant.
2
Dismantle machine side panels and clean machine inside with dry reduced com-
1
pressed air
NOTE!
Risk of damage to electronic components.
Clean electronic components from a certain distance only.
Clean also the water coolers in the case of excessive dust
1
Change the coolant
1
Dispose of used coolant correctly.
2
With respect to cooling units, the warranty provisions of the “General Terms of Delivery
and Payment” referred to in the pricelist shall only apply where the following conditions
are fulfilled:
-max. 8 operating hours per day (single-shift operation)
-only Fronius coolant may be used
-the unit is given regular maintenance and the coolant is changed regularly
29
DisposalDispose of in accordance with the applicable national and local regulations.
30
Troubleshooting
EN
Safety
Troubleshooting
WARNING!
An electric shock can be fatal.
Before opening up the unit:
Shift the mains switch into the “O” position
▶
Unplug the unit from the mains
▶
Put up an easy-to-understand warning sign to stop anybody inadvertently switching
▶
it back on again
Using a suitable measuring instrument, check to make sure that electrically charged
▶
components (e.g. capacitors) have been discharged
CAUTION!
Inadequate PE conductor connections can cause serious injury and damage.
The housing screws provide a suitable PE conductor connection for earthing (grounding)
the housing and must NOT be replaced by any other screws which do not provide a reliable PE conductor connection.
Not enough coolant circulation, or none at all
Cause:
Remedy:
Coolant level is too low
Top up the reservoir with coolant
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Constriction or foreign body in the cooling circuit
Eliminate the constriction or foreign body
Fuse for coolant pump is faulty
Replace the coolant pump fuse, as described in the section headed “Fuse
protection of the cooling-unit”
Coolant pump is faulty
Replace the coolant pump
The coolant filter in the plug-type connector for coolant return-flow is
blocked
Clean the coolant filter with clean tap water or replace the filter-insert
Permissible duty cycle exceeded
Await cooling-down phase of the coolant pump
31
Cooling capacity too low
Cause:
Remedy:
Fan defective
Replace fan
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
High operating noise level
Cause:
Remedy:
Cause:
Remedy:
Cooling pump defective
Replace coolant pump
Cooler contaminated
Clean cooler with dry compressed air
Cooling capacity of cooling unit too low
Use cooling unit with higher cooling capacity
Coolant level too low
Refill coolant
Cooling pump defective
Replace coolant pump
32
Technical data
EN
General remarks
FK 6000
NOTE!
Inadequately dimensioned electrical installations can lead to serious damage to
(or loss of) property.
The mains supply lead, and its fuse protection, must be dimensioned accordingly. The
technical data shown on the rating plate shall apply.
The cooling capacity of a cooling unit will depend upon:
-the ambient temperature
-the maximum rise
-the flow-rate Q (l/min)
The flow-rate Q will depend upon:
-the number of interconnecting hosepacks or connection hoses, and their lengths