FK 4000
FK 4000 R
FK 4000 R US
FK 4000 R FC
FK 4000 Rob
Operating instructions
EN
Cooling unit
42,0426,0017,EN 011-01062021
Page 2
Page 3
Contents
Safety rules5
Explanation of safety notices5
General5
Proper use5
Environmental conditions6
Obligations of the operator6
Obligations of personnel6
Mains connection6
Protecting yourself and others7
Noise emission values7
Danger from toxic gases and vapours8
Danger from flying sparks8
Risks from mains current and welding current9
Meandering welding currents10
EMC Device Classifications10
EMC measures10
EMF measures11
Specific hazards11
Requirement for the shielding gas12
Danger from shielding gas cylinders12
Danger from escaping shielding gas13
Safety measures at the installation location and during transport13
Safety measures in normal operation13
Commissioning, maintenance and repair14
Safety inspection14
Disposal15
Safety symbols15
Data protection15
Copyright15
General16
Device concept16
Scope of supply16
Validity of "General Delivery and Payment Conditions"16
Information about the coolant16
Information on leaks17
Warning notices on the device17
Application areas18
FK 400018
FK 4000 R, FK 4000 Rob, FK 4000 R FC, FK 4000 R US18
Options19
FK 4000 auto-transformer19
FK 4000 R flow sensor with coolant filter19
Thermostat19
Coolant filter20
Control elements and connections21
Safety21
Control elements and connections21
Before installation and commissioning22
Safety22
Setup regulations22
Information about the coolant23
Guarantee provisions regarding the coolant pump23
Proper use23
Fitting coolant connections to the front of the unit24
Safety24
General24
Fitting coolant connections to the front of the unit24
Adapting the cooling unit to the respective mains voltage26
Safety26
General26
EN
3
Page 4
Possible mains voltages for FK 4000, FK 4000 R, FK 4000 Rob and FK 4000 R FC27
Possible mains voltages for FK 4000 R US27
Adapting the cooling unit to the respective mains voltage27
Fitting the cooling unit to the trolley29
General29
Fitting the cooling unit to the trolley29
Connecting the cooling unit to the power source30
Safety30
Connecting the cooling unit to the power source30
Connecting the hosepacks to the cooling unit32
Safety32
Connect the interconnecting hosepack coolant hoses to the cooling unit (TS/TPS 4000/5000)32
Connecting the welding torch coolant hoses to the cooling unit (TPS 2700)32
Putting the cooling unit into service34
Safety34
General34
Filling the cooling unit34
Commissioning the cooling unit35
Care, maintenance and disposal36
Safety36
General36
Symbols for care and maintenance of the cooling unit37
Maintenance intervals, maintenance work37
Gas purge the cooler38
Changing the coolant38
Notes on changing the welding torch39
Disposal39
Troubleshooting41
Troubleshooting43
Safety43
General43
Fuse-protecting the cooling unit44
Troubleshooting44
Twisting the coolant pump shaft47
Safety47
Turning the coolant pump shaft47
Technical data48
General 48
FK 400048
FK 4000 R, FK 4000 R FC48
FK 4000 Rob49
FK 4000 R US49
4
Page 5
Safety rules
EN
Explanation of
safety notices
DANGER!
Indicates immediate danger.
If not avoided, death or serious injury will result.
▶
WARNING!
Indicates a potentially hazardous situation.
If not avoided, death or serious injury may result.
▶
CAUTION!
Indicates a situation where damage or injury could occur.
If not avoided, minor injury and/or damage to property may result.
▶
NOTE!
Indicates a risk of flawed results and possible damage to the equipment.
GeneralThe device is manufactured using state-of-the-art technology and according to recog-
nised safety standards. If used incorrectly or misused, however, it can cause:
-injury or death to the operator or a third party,
-damage to the device and other material assets belonging to the operating company,
-inefficient operation of the device.
All persons involved in commissioning, operating, maintaining and servicing the device
must:
-be suitably qualified,
-have sufficient knowledge of welding and
-read and follow these operating instructions carefully.
The operating instructions must always be at hand wherever the device is being used. In
addition to the operating instructions, attention must also be paid to any generally applicable and local regulations regarding accident prevention and environmental protection.
All safety and danger notices on the device
-must be in a legible state,
-must not be damaged,
-must not be removed,
-must not be covered, pasted or painted over.
For the location of the safety and danger notices on the device, refer to the section
headed "General" in the operating instructions for the device.
Before switching on the device, rectify any faults that could compromise safety.
This is for your personal safety!
Proper useThe device is to be used exclusively for its intended purpose.
5
Page 6
The device is intended solely for the welding processes specified on the rating plate.
Any use above and beyond this purpose is deemed improper. The manufacturer shall not
be held liable for any damage arising from such usage.
Proper use includes:
-carefully reading and following all the instructions given in the operating instructions
-studying and obeying all safety and danger notices carefully
-performing all stipulated inspection and maintenance work.
Never use the device for the following purposes:
-Thawing out pipes
-Charging batteries
-Starting engines
The device is designed for use in industry and the workshop. The manufacturer accepts
no responsibility for any damage caused through use in a domestic setting.
The manufacturer likewise accepts no liability for inadequate or incorrect results.
Environmental
conditions
Obligations of the
operator
Operation or storage of the device outside the stipulated area will be deemed as not in
accordance with the intended purpose. The manufacturer shall not be held liable for any
damage arising from such usage.
Ambient temperature range:
-during operation: -10 °C to + 40 °C (14 °F to 104 °F)
-during transport and storage: -20 °C to +55 °C (-4 °F to 131 °F)
Relative humidity:
-up to 50% at 40 °C (104 °F)
-up to 90% at 20 °C (68 °F)
The surrounding air must be free from dust, acids, corrosive gases or substances, etc.
Can be used at altitudes of up to 2000 m (6561 ft. 8.16 in.)
The operator must only allow persons to work with the device who:
-are familiar with the fundamental instructions regarding safety at work and accident
prevention and have been instructed in how to use the device
-have read and understood these operating instructions, especially the section
"safety rules", and have confirmed as much with their signatures
-are trained to produce the required results.
Checks must be carried out at regular intervals to ensure that operators are working in a
safety-conscious manner.
Obligations of
personnel
Mains connectionDevices with a higher rating may affect the energy quality of the mains due to their cur-
6
Before using the device, all persons instructed to do so undertake:
-to observe the basic instructions regarding safety at work and accident prevention
-to read these operating instructions, especially the "Safety rules" section and sign to
confirm that they have understood them and will follow them.
Before leaving the workplace, ensure that people or property cannot come to any harm
in your absence.
rent consumption.
Page 7
This may affect a number device types in terms of:
-Connection restrictions
-
Criteria with regard to the maximum permissible mains impedance
-
Criteria with regard to the minimum short-circuit power requirement
*)
at the interface with the public grid
*)
*)
see "Technical data"
In this case, the plant operator or the person using the device should check whether the
device may be connected, where appropriate by discussing the matter with the power
supply company.
IMPORTANT! Ensure that the mains connection is earthed properly
EN
Protecting yourself and others
Anyone working with the device exposes themselves to numerous risks, e.g.
-flying sparks and hot pieces of metal
-Arc radiation, which can damage eyes and skin
-Hazardous electromagnetic fields, which can endanger the lives of those using cardiac pacemakers
-Risk of electrocution from mains current and welding current
-Greater noise pollution
-Harmful welding fumes and gases
Suitable protective clothing must be worn when working with the device. The protective
clothing must have the following properties:
-Flame-resistant
-Insulating and dry
-Covers the whole body, is undamaged and in good condition
-Safety helmet
-Trousers with no turn-ups
Protective clothing refers to a variety of different items. Operators should:
-Protect eyes and face from UV rays, heat and sparks using a protective visor and
regulation filter
-Wear regulation protective goggles with side protection behind the protective visor
-Wear stout footwear that provides insulation even in wet conditions
-Protect the hands with suitable gloves (electrically insulated and providing protection
against heat)
-Wear ear protection to reduce the harmful effects of noise and to prevent injury
Noise emission
values
Keep all persons, especially children, out of the working area while any devices are in
operation or welding is in progress. If, however, there are people in the vicinity:
-Make them aware of all the dangers (risk of dazzling by the arc, injury from flying
sparks, harmful welding fumes, noise, possible risks from mains current and welding
current, etc.)
The device generates a maximum sound power level of <80 dB(A) (ref. 1pW) when idling
and in the cooling phase following operation at the maximum permissible operating point
under maximum rated load conditions according to EN 60974-1.
It is not possible to provide a workplace-related emission value during welding (or cutting) as this is influenced by both the process and the environment. All manner of different welding parameters come into play, including the welding process (MIG/MAG, TIG
welding), the type of power selected (DC or AC), the power range, the type of weld
metal, the resonance characteristics of the workpiece, the workplace environment, etc.
7
Page 8
Danger from
toxic gases and
vapours
The fumes produced during welding contain harmful gases and vapours.
Welding fumes contain substances that cause cancer, as stated in Monograph 118 of the
International Agency for Research on Cancer.
Use at-source extraction and a room extraction system.
If necessary, use a welding torch with an integrated extraction device.
Keep your face away from welding fumes and gases.
Fumes and hazardous gases
-must not be breathed in
-must be extracted from the working area using appropriate methods.
Ensure an adequate supply of fresh air. Ensure that there is a ventilation rate of at least
20 m³ per hour at all times.
Otherwise, a welding helmet with an air supply must be worn.
If there is any doubt about whether the extraction capacity is sufficient, the measured
toxic emission values should be compared with the permissible limit values.
The following components are responsible, amongst other things, for the degree of toxicity of welding fumes:
-Metals used for the workpiece
-Electrodes
-Coatings
-Cleaners, degreasers, etc.
-Welding process used
Danger from flying sparks
The relevant material safety data sheets and manufacturer's specifications for the listed
components should therefore be studied carefully.
Recommendations for trade fair scenarios, risk management measures and for identifying working conditions can be found on the European Welding Association website under
Health & Safety (https://european-welding.org).
Flammable vapours (e.g. solvent fumes) should be kept away from the arc's radiation
area.
Close the shielding gas cylinder valve or main gas supply if no welding is taking place.
Flying sparks may cause fires or explosions.
Never weld close to flammable materials.
Flammable materials must be at least 11 metres (36 ft. 1.07 in.) away from the arc, or
alternatively covered with an approved cover.
A suitable, tested fire extinguisher must be available and ready for use.
Sparks and pieces of hot metal may also get into adjacent areas through small gaps or
openings. Take appropriate precautions to prevent any danger of injury or fire.
Welding must not be performed in areas that are subject to fire or explosion or near
sealed tanks, vessels or pipes unless these have been prepared in accordance with the
relevant national and international standards.
Do not carry out welding on containers that are being or have been used to store gases,
propellants, mineral oils or similar products. Residues pose an explosive hazard.
8
Page 9
Risks from mains
current and welding current
An electric shock is potentially life threatening and can be fatal.
Do not touch live parts either inside or outside the device.
During MIG/MAG welding and TIG welding, the welding wire, the wirespool, the feed
rollers and all pieces of metal that are in contact with the welding wire are live.
Always set the wirefeeder up on a sufficiently insulated surface or use a suitable, insulated wirefeeder holder.
Make sure that you and others are protected with an adequately insulated, dry base or
cover for the earth or ground potential. This base or cover must extend over the entire
area between the body and the earth or ground potential.
All cables and leads must be secured, undamaged, insulated and adequately dimensioned. Replace loose connections and scorched, damaged, or inadequately dimensioned cables and leads immediately.
Use the handle to ensure the power connections are tight before every use.
In the case of power cables with a bayonet connector, rotate the power cable around the
longitudinal axis by at least 180° and pretension.
Do not wrap cables or leads around the body or parts of the body.
The electrode (rod electrode, tungsten electrode, welding wire, etc.) must
-never be immersed in liquid for cooling
-Never touch the electrode when the power source is switched on.
EN
Double the open circuit voltage of a power source can occur between the welding electrodes of two power sources. Touching the potentials of both electrodes at the same time
may be fatal under certain circumstances.
Arrange for the mains cable to be checked regularly by a qualified electrician to ensure
the ground conductor is functioning properly.
Protection class I devices require a mains supply with ground conductor and a connector
system with ground conductor contact for proper operation.
Operation of the device on a mains supply without ground conductor and on a socket
without ground conductor contact is only permitted if all national regulations for protective
separation are observed.
Otherwise, this is considered gross negligence. The manufacturer shall not be held liable
for any damage arising from such usage.
If necessary, provide adequate earthing for the workpiece.
Switch off unused devices.
Wear a safety harness if working at height.
Before working on the device, switch it off and pull out the mains plug.
Attach a clearly legible and easy-to-understand warning sign to the device to prevent
anyone from plugging the mains plug back in and switching it on again.
After opening the device:
-Discharge all live components
-Ensure that all components in the device are de-energised.
If work on live parts is required, appoint a second person to switch off the main switch at
the right moment.
9
Page 10
Meandering welding currents
If the following instructions are ignored, meandering welding currents can develop with
the following consequences:
-Fire hazard
-Overheating of parts connected to the workpiece
-Irreparable damage to ground conductors
-Damage to device and other electrical equipment
Ensure that the workpiece is held securely by the workpiece clamp.
Attach the workpiece clamp as close as possible to the area that is to be welded.
Position the device with sufficient insulation against electrically conductive environments,
e.g. Insulation against conductive floor or insulation to conductive racks.
If distribution boards, twin-head mounts, etc., are being used, note the following: The
electrode of the welding torch / electrode holder that is not used is also live. Make sure
that the welding torch / electrode holder that is not used is kept sufficiently insulated.
In the case of automated MIG/MAG applications, ensure that only an insulated wire electrode is routed from the welding wire drum, large wirefeeder spool or wirespool to the
wirefeeder.
EMC Device Classifications
EMC measuresIn certain cases, even though a device complies with the standard limit values for emis-
Devices in emission class A:
-Are only designed for use in industrial settings
-Can cause line-bound and radiated interference in other areas
Devices in emission class B:
-Satisfy the emissions criteria for residential and industrial areas. This is also true for
residential areas in which the energy is supplied from the public low-voltage mains.
EMC device classification as per the rating plate or technical data.
sions, it may affect the application area for which it was designed (e.g. when there is
sensitive equipment at the same location, or if the site where the device is installed is
close to either radio or television receivers).
If this is the case, then the operator is obliged to take appropriate action to rectify the
situation.
Check and evaluate the immunity to interference of nearby devices according to national
and international regulations. Examples of equipment that may be susceptible to interference from the device include:
-Safety devices
-Power, signal and data transfer lines
-IT and telecommunications devices
-Measuring and calibrating devices
10
Supporting measures for avoidance of EMC problems:
tional measures are necessary (e.g. use a suitable line filter).
2.Welding power leads
-must be kept as short as possible
-must run close together (to avoid EMF problems)
-must be kept well apart from other leads
3.Equipotential bonding
4.Earthing of the workpiece
-If necessary, establish an earth connection using suitable capacitors.
Page 11
5.Shielding, if necessary
-Shield off other nearby devices
-Shield off entire welding installation
EMF measuresElectromagnetic fields may pose as yet unknown risks to health:
-effects on the health of others in the vicinity, e.g. wearers of pacemakers and hearing aids
-wearers of pacemakers must seek advice from their doctor before approaching the
device or any welding that is in progress
-for safety reasons, keep distances between the welding cables and the welder's
head/torso as large as possible
-do not carry welding cables and hosepacks over the shoulders or wind them around
any part of the body
Specific hazardsKeep hands, hair, clothing and tools away from moving parts. For example:
-Fans
-Cogs
-Rollers
-Shafts
-Wirespools and welding wires
EN
Do not reach into the rotating cogs of the wire drive or into rotating drive components.
Covers and side panels may only be opened/removed while maintenance or repair work
is being carried out.
During operation
-Ensure that all covers are closed and all side panels are fitted properly.
-Keep all covers and side panels closed.
The welding wire emerging from the welding torch poses a high risk of injury (piercing of
the hand, injuries to the face and eyes, etc.).
Therefore always keep the welding torch away from the body (devices with wire-feed
unit) and wear suitable protective goggles.
Never touch the workpiece during or after welding - risk of burns.
Slag can jump off cooling workpieces. The specified protective equipment must therefore
also be worn when reworking workpieces, and steps must be taken to ensure that other
people are also adequately protected.
Welding torches and other parts with a high operating temperature must be allowed to
cool down before handling.
Special provisions apply in areas at risk of fire or explosion - observe relevant
national and international regulations.
Power sources for work in areas with increased electric risk (e.g. near boilers) must carry
the "Safety" sign. However, the power source must not be located in such areas.
Risk of scalding from escaping coolant. Switch off cooling unit before disconnecting
coolant flow or return lines.
Observe the information on the coolant safety data sheet when handling coolant. The
coolant safety data sheet may be obtained from your service centre or downloaded from
the manufacturer's website.
Use only suitable load-carrying equipment supplied by the manufacturer when transporting devices by crane.
11
Page 12
-Hook chains and/or ropes onto all suspension points provided on the load-carrying
equipment.
-Chains and ropes must be at the smallest angle possible to the vertical.
-Remove gas cylinder and wire-feed unit (MIG/MAG and TIG devices).
If the wire-feed unit is attached to a crane holder during welding, always use a suitable,
insulated wirefeeder hoisting attachment (MIG/MAG and TIG devices).
If the device has a carrying strap or handle, this is intended solely for carrying by hand.
The carrying strap is not to be used if transporting with a crane, counterbalanced lift truck
or other mechanical hoist.
All lifting accessories (straps, handles, chains, etc.) used in connection with the device or
its components must be tested regularly (e.g. for mechanical damage, corrosion or
changes caused by other environmental factors).
The testing interval and scope of testing must comply with applicable national standards
and directives as a minimum.
Odourless and colourless shielding gas may escape unnoticed if an adapter is used for
the shielding gas connection. Prior to assembly, seal the device-side thread of the
adapter for the shielding gas connection using suitable Teflon tape.
Requirement for
the shielding gas
Danger from
shielding gas cylinders
Especially with ring lines, contaminated shielding gas can cause damage to equipment
and reduce welding quality.
Meet the following requirements regarding shielding gas quality:
-Solid particle size < 40 µm
-Pressure condensation point < -20 °C
-Max. oil content < 25 mg/m³
Use filters if necessary.
Shielding gas cylinders contain gas under pressure and can explode if damaged. As the
shielding gas cylinders are part of the welding equipment, they must be handled with the
greatest of care.
Protect shielding gas cylinders containing compressed gas from excessive heat, mechanical impact, slag, naked flames, sparks and arcs.
Mount the shielding gas cylinders vertically and secure according to instructions to prevent them falling over.
Keep the shielding gas cylinders well away from any welding or other electrical circuits.
Never hang a welding torch on a shielding gas cylinder.
Never touch a shielding gas cylinder with an electrode.
12
Risk of explosion - never attempt to weld a pressurised shielding gas cylinder.
Only use shielding gas cylinders suitable for the application in hand, along with the correct and appropriate accessories (regulator, hoses and fittings). Only use shielding gas
cylinders and accessories that are in good condition.
Turn your face to one side when opening the valve of a shielding gas cylinder.
Close the shielding gas cylinder valve if no welding is taking place.
If the shielding gas cylinder is not connected, leave the valve cap in place on the cylinder.
Page 13
The manufacturer's instructions must be observed as well as applicable national and
international regulations for shielding gas cylinders and accessories.
EN
Danger from
escaping shielding gas
Safety measures
at the installation
location and during transport
Risk of suffocation from the uncontrolled escape of shielding gas
Shielding gas is colourless and odourless and, in the event of a leak, can displace the
oxygen in the ambient air.
-Ensure an adequate supply of fresh air with a ventilation rate of at least 20 m³/hour.
-Observe safety and maintenance instructions on the shielding gas cylinder or the
main gas supply.
-Close the shielding gas cylinder valve or main gas supply if no welding is taking
place.
-Check the shielding gas cylinder or main gas supply for uncontrolled gas leakage
before every start-up.
A device toppling over could easily kill someone. Place the device on a solid, level surface such that it remains stable
-The maximum permissible tilt angle is 10°.
Special regulations apply in rooms at risk of fire or explosion
-Observe relevant national and international regulations.
Use internal directives and checks to ensure that the workplace environment is always
clean and clearly laid out.
Only set up and operate the device in accordance with the degree of protection shown
on the rating plate.
Safety measures
in normal operation
When setting up the device, ensure there is an all-round clearance of 0.5 m (1 ft. 7.69
in.) to ensure that cooling air can flow in and out freely.
When transporting the device, observe the relevant national and local guidelines and
accident prevention regulations. This applies especially to guidelines regarding the risks
arising during transport.
Do not lift or transport operational devices. Switch off devices before transport or lifting.
Before transporting the device, allow coolant to drain completely and detach the following components:
-Wirefeeder
-Wirespool
-Shielding gas cylinder
After transporting the device, the device must be visually inspected for damage before
commissioning. Any damage must be repaired by trained service technicians before
commissioning the device.
Only operate the device when all safety devices are fully functional. If the safety devices
are not fully functional, there is a risk of
-injury or death to the operator or a third party
-damage to the device and other material assets belonging to the operator
-inefficient operation of the device
Any safety devices that are not functioning properly must be repaired before switching on
the device.
Never bypass or disable safety devices.
13
Page 14
Before switching on the device, ensure that no one is likely to be endangered.
Check the device at least once a week for obvious damage and proper functioning of
safety devices.
Always fasten the shielding gas cylinder securely and remove it beforehand if the device
is to be transported by crane.
Only the manufacturer's original coolant is suitable for use with our devices due to its
properties (electrical conductibility, anti-freeze agent, material compatibility, flammability,
etc.).
Only use suitable original coolant from the manufacturer.
Do not mix the manufacturer's original coolant with other coolants.
Only connect the manufacturer's system components to the cooling circuit.
The manufacturer accepts no liability for damage resulting from use of other system
components or a different coolant. In addition, all warranty claims will be forfeited.
Cooling Liquid FCL 10/20 does not ignite. The ethanol-based coolant can ignite under
certain conditions. Transport the coolant only in its original, sealed containers and keep
well away from any sources of ignition.
Used coolant must be disposed of properly in accordance with the relevant national and
international regulations. The coolant safety data sheet may be obtained from your service centre or downloaded from the manufacturer's website.
Check the coolant level before starting to weld, while the system is still cool.
Commissioning,
maintenance and
repair
Safety inspectionThe manufacturer recommends that a safety inspection of the device is performed at
It is impossible to guarantee that bought-in parts are designed and manufactured to meet
the demands made of them, or that they satisfy safety requirements.
-Use only original spare and wearing parts (also applies to standard parts).
-Do not carry out any modifications, alterations, etc. to the device without the manufacturer's consent.
-Components that are not in perfect condition must be replaced immediately.
-When ordering, please give the exact designation and part number as shown in the
spare parts list, as well as the serial number of your device.
The housing screws provide the ground conductor connection for earthing the housing
parts.
Only use original housing screws in the correct number and tightened to the specified
torque.
least once every 12 months.
The manufacturer recommends that the power source be calibrated during the same 12month period.
14
A safety inspection should be carried out by a qualified electrician
-after any changes are made
-after any additional parts are installed, or after any conversions
-after repair, care and maintenance has been carried out
-at least every twelve months.
For safety inspections, follow the appropriate national and international standards and
directives.
Page 15
Further details on safety inspection and calibration can be obtained from your service
centre. They will provide you on request with any documents you may require.
DisposalDo not dispose of this device with normal domestic waste! To comply with the European
Directive on Waste Electrical and Electronic Equipment and its implementation as
national law, electrical equipment that has reached the end of its life must be collected
separately and returned to an approved recycling facility. Any device that you no longer
require must either be returned to your dealer or given to one of the approved collection
and recycling facilities in your area. Ignoring this European Directive may have potentially adverse affects on the environment and your health!
Safety symbolsDevices with the CE mark satisfy the essential requirements of the low-voltage and elec-
tromagnetic compatibility directives (e.g. relevant product standards of the EN 60 974
series).
Fronius International GmbH hereby declares that the device is compliant with Directive
2014/53/EU. The full text on the EU Declaration of Conformity can be found at the following address: http://www.fronius.com
Devices marked with the CSA test mark satisfy the requirements of the relevant standards for Canada and the USA.
EN
Data protectionThe user is responsible for the safekeeping of any changes made to the factory settings.
The manufacturer accepts no liability for any deleted personal settings.
CopyrightCopyright of these operating instructions remains with the manufacturer.
The text and illustrations are all technically correct at the time of printing. We reserve the
right to make changes. The contents of the operating instructions shall not provide the
basis for any claims whatsoever on the part of the purchaser. If you have any suggestions for improvement, or can point out any mistakes that you have found in the instructions, we will be most grateful for your comments.
15
Page 16
General
Device conceptFive cooling units are available for cooling
the power sources listed below:
-FK 4000 with oscillating armature
pump and auto-transformer
-FK 4000 R with centrifugal pump
-FK 4000 R FC with centrifugal pump
and flow sensor with coolant filter
-FK 4000 R US with centrifugal pump,
auto-transformer and flow sensor with
coolant filter
-FK 4000 Rob with magneticallycoupled centrifugal pump, flow sensor
with coolant filter and thermostat
The cooling units described in these instructions can be operated with all power sources
in the:
-TransSynergic 4000 / 5000 series
-TransPuls Synergic 2700 series
-TransPuls Synergic 3200 / 4000 / 5000 series
-TransTig 2200 / 4000 / 5000 series
-MagicWave 1700 / 2200 / 4000 / 5000 series
Scope of supply-Cooling unit
-5 l coolant in a canister
-Four Allen screws (for securing the power source on the cooling unit)
-Four M5 nuts (for securing the power source on the cooling unit)
-One 2 A fuse (spare)
-Operating instructions
Validity of "General Delivery and
Payment Conditions"
Information about
the coolant
With regard to cooling units, the "General Delivery and Payment Conditions" according to
the price list only apply under the following conditions:
-Only original coolant from the manufacturer is used
-Regular maintenance and regular change of coolant
CAUTION!
Danger from using non-permitted coolant.
This can result in serious damage to property.
Only use coolant available from the manufacturer.
▶
Do not mix different coolants.
▶
When changing the coolant, make sure all the coolant is replaced.
▶
When switching from ethanol-based coolant to FCL 10 coolant, Change Kit FCL10
▶
must be used and the instructions provided must be followed.
16
Page 17
Information on
4 bar (0.4 MPa)2 kW
P
1l/min
1~
50-60 Hz
IEC 60 974-2/-10 Cl.AIP 23
0.6 A
U
1
400 V
p
max
A-4600 Wels
www.fronius.com
Ser.No.:
Part No.:
Type:
p
max
Imax
leaks
The following information on leaks does not apply to the FK 4000 Rob.
The shaft sealing surfaces inside the coolant pump are lubricated by the coolant, meaning that a certain leakage flow should always be expected. A low leakage flow is permitted.
The coolant pump requires a certain warm-up time after being started for the first time or
upon restarting after a long period of downtime. An increased leakage flow can occur
during this warm-up phase. The leakage flow will normally sink back down to a low level
after the warm-up phase. If this is not the case then contact After-Sales Service.
EN
Warning notices
on the device
The cooling unit is fitted with safety symbols and a rating plate. The rating plate and
safety symbols must not be removed or painted over. The symbols warn against operating the equipment incorrectly, as this may result in serious injury and damage.
Welding is dangerous. The following basic requirements must be met to
ensure the equipment is used properly:
-Welders must be sufficiently qualified
-Suitable protective equipment must be used
-All persons not involved must be kept at a safe distance from the cooling unit and the welding process
Do not use the functions described here until you have thoroughly read and
understood the following documents:
-these operating instructions
-all the operating instructions for the system components, especially
the safety rules
Do not dispose of used devices with domestic waste. Dispose of them
according to the safety rules.
17
Page 18
Application areas
FK 4000The cooling unit is recommended for use with:
-TransPuls Synergic 2700
-TransSynergic 4000 and TransPuls Synergic 4000, max. length of the interconnecting hosepack 5 m (16 ft. 5 in.)
-TransSynergic 5000 and TransPuls Synergic 5000, max. length of the interconnecting hosepack 1.2 m (4 ft.)
NOTE!
The cooling unit is supplied with the auto-transformer FK 4000 option as standard.
FK 4000 R, FK
4000 Rob, FK
4000 R FC, FK
4000 R US
The cooling units are recommended for use with:
-TransSynergic 4000 and TransPuls Synergic 4000, length of the interconnecting
hosepack over 5 m (16 ft. 5 in.)
-TransSynergic 5000 and TransPuls Synergic 5000, length of the interconnecting
hosepack over 1.2 m (4 ft.)
-PullMig or PushPull hosepacks
-Multilock hosepacks
-Robacta machine hosepacks
-Robacta or Robacta Drive robot hosepacks
-TIME and JobMaster welding torches
-MIG/MAG pulsed arc welding
-Welding in a higher power range
-Robot welding
Additional information for FK 4000 R FC:
-The flow sensor with coolant filter option is fitted as standard in the cooling unit
Additional information for FK 4000 Rob:
-The flow sensor with coolant filter option is fitted as standard in the cooling unit
-The thermostat option is fitted as standard in the cooling unit
Additional information for FK 4000 R US:
-The flow sensor with coolant filter option is fitted as standard in the cooling unit
-The FK 4000 auto-transformer option is fitted as standard in the cooling unit
-The cooling unit is intended for the American market. The other cooling units are not
available on the American market
18
Page 19
Options
EN
FK 4000 autotransformer
FK 4000 R flow
sensor with
coolant filter
This option is available for the following devices:
-FK 4000 R
-FK 4000 Rob
-FK 4000 R FC
The FK 4000 and FK 4000 R US cooling units are equipped with the FK 4000 auto-transformer option as standard.
-The FK 4000 auto-transformer is required if the cooling unit must be operated using
a multivoltage power source (MV). The multivoltage power source has an input
voltage of 3 x 200 - 240 V / 3 x 380 - 460 V (+/- 10%)
-The FK 4000 auto-transformer converts this voltage from the power source into what
the cooling unit needs
This option is available for the following devices:
-FK 4000 - only if the interconnecting hosepack does not exceed a length of 5 m (16
ft. 5 in.)
-FK 4000 R
The FK 4000 R US, FK 4000 R FC and FK 4000 Rob cooling units are fitted with the flow
sensor with coolant filter option as standard.
How it works:
-The option monitors the coolant flow during welding
-If the coolant flow falls below 0.7l/min (0.18 gal./min [US]), "no | H2" is automatically
displayed, the welding current is interrupted and the cooling unit switches off
-If the welding system has a Comfort or WeldProcessData (OPC Fronius LocalNet
server) control panel, the coolant flow can be shown on it
•To display the coolant flow value, press the F3 parameter selection / indicator
key on the Comfort control panel
A disruption in the coolant flow can occur as a result of:
-Insufficient coolant
-Contaminated coolant
-Leaks in the cooling circuit
-Faulty coolant pump
-Frozen coolant (welding at too low a temperature)
ThermostatThis option is available for the following devices:
-FK 4000
-FK 4000 R
-FK 4000 R FC
-FK 4000 R US
The FK 4000 Rob cooling unit has a thermostat option as standard.
19
Page 20
-The thermostat option monitors the coolant temperature
-If the coolant temperature rises to above 70°C (185°F), the "hot | H2" indicator is
automatically displayed and the welding current is interrupted. The cooling unit
remains operational
-The thermostat restores the welding current when the temperature falls to 65°C
(149°F).
Coolant filterThe coolant filter is equipped with a CrNi screen; its function is to filter dirt particles
above 100 micrometres in size from the coolant. This ensures that no coarse dirt
particles can pass into the coolant circuit. The coolant filter is fitted to the coolant return
connection on the cooling unit.
20
Page 21
Control elements and connections
(1)(2) (3) (4)
(5)(6)(7)(8)
(9)(10)
(11)
(12)
(13)
EN
Safety
Control elements
and connections
WARNING!
Operating the equipment incorrectly can cause serious injury and damage.
All functions described in this document must only be used by trained and qualified personnel. Do not use any of the functions described until you have thoroughly read and
understood the following documents:
this document
▶
all the operating instructions for the system components, especially the safety rules
▶
(1)Fill nozzle with screw cap
(2)Fuse for coolant pump
(3)Blanking cover or coolant return connection (red)
(4)Connector
(5)Blanking cover or coolant flow connection (blue)
(6)Rating plate
(7)Operating and maintenance instructions
(8)Viewing window for coolant level
(9)Blanking cover or coolant return connection (red)
(10)Mounting plate for coolant filter
(included in scope of supply of flow sensor with coolant filter option)
(11)Coolant filter
(included in scope of supply of flow sensor with coolant filter option)
(12)Drain hose
(13)Blanking cover or coolant flow connection (blue)
21
Page 22
Before installation and commissioning
Safety
Setup regulations
WARNING!
Danger due to incorrect operation and incorrectly performed work.
This can result in severe personal injury and damage to property.
All the work and functions described in this document must only be carried out and
▶
used by trained and qualified personnel.
Fully read and understand this document.
▶
Fully read and understand all the Operating Instructions for the system components,
▶
especially the safety rules.
WARNING!
Danger from machines falling or toppling over.
This can result in serious injury and damage to property.
Place all system components on a solid, level surface in such a way that they
▶
remain stable.
WARNING!
Danger from electric current.
An electric shock can be fatal.
Ensure the cooling unit is properly insulated.
▶
Always ensure that there is no electrically conductive connection between the base
▶
plate of the cooling unit and the surface.
Before installing the cooling unit, remove all electrically conductive parts between
▶
the base plate of the cooling unit and the surface.
The device is tested to IP 23 protection, meaning:
-Protection against penetration by solid foreign bodies with diameters > 12.5 mm
(0.49 in.)
-Protection against spraywater at any angle up to 60° to the vertical
Cooling air
The system must be set up in such a way that the cooling air can flow unimpeded
through the slots in the side panels. Ensure that there is always an all-round clearance of
0.5 m (1 ft 7.69 in.) around the device.
CAUTION!
Risk from insufficient cooling air supply.
This can result in serious damage to property.
Air inlets and outlets must never be covered, not even partially.
▶
Dust
Ensure that any metallic dust, for example from grinding work, is not sucked into the system by the fan.
Outdoor operation
The device can be set up and operated outdoors in accordance with degree of protection
IP23. Avoid direct wetting (e.g. from rain).
22
Page 23
Information about
the coolant
The cooling unit is delivered empty.
Use only original Fronius coolant (Cooling Liquid FCL 10/20 or torch coolant) when filling
the cooling unit. Other coolants are not recommended for electrical conductivity and
material compatibility reasons.
EN
Guarantee provisions regarding
the coolant pump
Proper useThe device is intended solely for use in conjunction with Fronius system components.
The coolant pump may only be used with original coolant supplied by the manufacturer.
Do not allow the coolant pump to run dry (even for a very short time), as this will destroy
the coolant pump. The manufacturer accepts no liability for damage caused in such
cases.
The device is to be used exclusively for its intended purpose.
Any use above and beyond this purpose is deemed improper. The manufacturer is not
liable for any damage, or unexpected or incorrect results arising out of such misuse.
Proper use also includes:
-carefully reading these operating instructions
-following all the instructions and safety rules in these operating instructions
-performing all stipulated inspection and maintenance work
The device is designed for use in industry and the workshop. The manufacturer accepts
no responsibility for any damage caused through use in a domestic setting.
23
Page 24
Fitting coolant connections to the front of the unit
Safety
An electric shock can be fatal.
Before starting work:
▶
▶
▶
After opening the device, use a suitable measuring instrument to check that electrically
charged components (e.g. capacitors) have been discharged.
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the
housing and must NOT be replaced by any other screws that do not provide a reliable
ground conductor connection.
GeneralThe coolant connections can be installed either at the front of the cooling unit or at the
rear, thanks to the different central connectors.
WARNING!
turn the power source mains switch to the "O" position
disconnect the power source from the mains
ensure that the power source remains disconnected from the mains until all work
has been completed
WARNING!
Fitting coolant
connections to
the front of the
unit
When using the cooling unit with a TPS 2700, the coolant connections are to be moved
from the rear to the front of the cooling unit.
NOTE!
Make sure that no coolant enters the device.
If there is any coolant on the exterior of the device, remove it immediately.
Disconnect the cooling unit from all system components and ensure that it remains
1
so for the duration of all work
Unscrew the three screws from the right side panel (as seen from the front) of the
2
cooling unit and remove the side panel
Unscrew the plastic nuts from the coolant connections (1) and (2)
3
Route hoses for coolant return (3) and coolant flow (4) to the front panel
4
24
Page 25
(1)
(2)
(3) (4)
(5)
(5)
(1)
(2)
(5)
EN
Remove blanking covers (5) from the front and attach to the rear
5
NOTE!
Fit the coolant return connection (1) at
the top and secure using the red plastic
nut (coolant return is indicated by red
insulating tape).
Feed the coolant connection (1) and
6
(2) from the inside outwards through
the housing and secure to the front of
the unit using the previously
unscrewed plastic nuts
Fit the side panel to the cooling unit and secure using three screws
7
25
Page 26
Adapting the cooling unit to the respective mains
voltage
Safety
An electric shock can be fatal.
Before starting work:
▶
▶
▶
After opening the device, use a suitable measuring instrument to check that electrically
charged components (e.g. capacitors) have been discharged.
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the
housing and must NOT be replaced by any other screws that do not provide a reliable
ground conductor connection.
GeneralThe TS 4000 MV / 5000 MV and TPS 2700 MV / 4000 MV / 5000 MV power sources can
be operated as standard at a mains voltage of 3 x 200-240V / 3 x 380-460V (+/-10%).
The mains voltage switching in the power source takes place automatically.
WARNING!
turn the power source mains switch to the "O" position
disconnect the power source from the mains
ensure that the power source remains disconnected from the mains until all work
has been completed
WARNING!
The cooling units are factory-configured for the following mains voltages:
FK 4000= 3 x 230 / 400 V, 50 / 60 Hz, +/-10%
FK 4000 R= 3 x 400 V, 50 / 60 Hz, +/-10%
FK 4000 Rob= 3 x 400 V, 50 / 60 Hz, +/-10%
FK 4000 R FC= 3 x 400 V, 50 / 60 Hz, +/-10%
FK 4000 R US= 3 x 230 / 460 V, 50 / 60 Hz, +/- 10%
The cooling units are adapted accordingly for other mains voltages with the help of an
auto-transformer.
NOTE!
The auto-transformer is available as an option for the FK 4000 R, FK 4000 Rob and
FK 4000 R FC cooling units.
For the FK 4000 and FK 4000 R US cooling units, the auto-transformer is fitted as standard.
26
Page 27
Possible mains
(1)
(2)
voltages for FK
4000, FK 4000 R,
FK 4000 Rob and
FK 4000 R FC
The auto-transformer in the FK 4000, FK 4000 R and FK 4000 Rob cooling units can
be configured for the following mains voltages:
-3 x 200 / 400 V
-3 x 200 / 440 V
-3 x 200 / 460 V
-3 x 230 / 400 V (= factory configuration)
-3 x 230 / 440 V
-3 x 230 / 460 V
Mains frequency in each case 50 / 60 Hz, mains voltage tolerance +/- 10%.
EN
Possible mains
voltages for FK
4000 R US
Adapting the
cooling unit to
the respective
mains voltage
The auto-transformer in the FK 4000 R US cooling unit can be configured for the following mains voltages:
-3 x 200 / 400 V
-3 x 200 / 440 V
-3 x 200 / 460 V
-3 x 230 / 400 V
-3 x 230 / 440 V
-3 x 230 / 460 V (= factory configuration)
Mains frequency in each case 50 / 60 Hz, mains voltage tolerance +/- 10%.
NOTE!
To adapt the FK 4000 R, FK 4000 Rob and FK 4000 R FC cooling units for the
respective mains voltage, the optional auto-transformer must be installed on the
cooling unit.
Ensure that the cooling unit is discon-
1
nected from all system components
and remains so for the duration of all
work
Unscrew the three screws from the
2
right side panel (as seen from the
front) of the cooling unit and remove
the side panel
Loosen and remove the plastic film (1)
3
on the clip (2)
Remove plastic film
27
Page 28
(3)
(440 V)
(460 V)
Change the auto-transformer connections (example
shows FK 4000 R US)
Change the auto-transformer connec-
4
tions according to the circuit diagram:
connect the white cable (3) to the
required mains voltage (the image to
the left shows the reconnection of the
auto-transformer using the FK 4000 R
US as an example. The reconnection
is carried out in the same way for
other units; only the possible voltages
differ.
-In the circuit diagram for the unit,
the factory configuration is shown
by a solid line and the other
options by a dashed line.
The circuit diagram can be found
on the inside of the side panel.
28
Page 29
Fitting the cooling unit to the trolley
(3)
(2)
(*
(1)
GeneralThe welding system can be fitted to a trolley to make the entire system more mobile.
NOTE!
If the welding system is not equipped with an auto-transformer, the cooling unit
must be installed right at the bottom.
Fitting the cooling unit to the
trolley
EN
Place the cooling unit on the trolley base and fixing bracket (1)
1
NOTE!
The fixing brackets must be placed within the plastic feet (2) of the cooling unit.
Secure the cooling unit to the fixing brackets using the four TX 25 screws provided
2
(3), two at the front and two at the back
(*Trolley scope of supply
29
Page 30
Connecting the cooling unit to the power source
(1)
(5)
(*
(3)
(2)
Safety
Connecting the
cooling unit to
the power source
WARNING!
Danger from electric current.
An electric shock can be fatal.
Turn the power source mains switch to the "O" position.
▶
Disconnect the power source from the mains.
▶
Ensure that the power source remains disconnected from the mains until all work
▶
has been completed.
Insert the M5 nuts provided (5) into
1
the hexagon-shaped openings on the
fixing bars (1) from the inside
Unscrew the TX 25 screws from the
2
protective cover on the underside of
the power source and remove the protective cover (if present)
(*Cooling unit scope of supply
Pull the power source connector (2) as
3
far out of the power source as possible
Position the power source above the
4
cooling unit
Connect the power source connector
5
(2) to the cooling unit connector (3)
CAUTION!
Risk of short circuit from kinked or damaged cables.
When positioning the power source, ensure that the cable is not kinked.
30
Page 31
NOTE!
(4)
(2)
(1)
(3)
(*
When positioning the power source, the cooling unit fixing bars must be placed
within the plastic feet of the power source.
Placing the power source on the cooling unit
6
Secure the power source to the cooling unit fixing bars using the Allen screws
7
provided (4), two at the front and two at the back
EN
31
Page 32
Connecting the hosepacks to the cooling unit
(1)
(2)
(3)
Safety
Connect the
interconnecting
hosepack coolant
hoses to the
cooling unit
(TS/TPS
4000/5000)
WARNING!
Danger from electric current.
An electric shock can be fatal.
Turn the power source mains switch to the "O" position.
▶
Disconnect the power source from the mains.
▶
Ensure that the power source remains disconnected from the mains until all work
▶
has been completed.
NOTE!
For TS 4000 / 5000, TPS 3200 / 4000 / 5000 power sources, the power source (1)
must be connected to the cooling unit using an interconnecting hosepack.
Plug in and secure the interconnecting
1
hosepack strain-relief device (1) in the
opening provided on the base of the
trolley (see trolley operating instructions)
Connect the red hose from the inter-
2
connecting hosepack (2) to the
coolant return connection on the cooling unit
Connect the blue hose from the inter-
3
connecting hosepack (3) to the
coolant flow connection on the cooling
unit
Connecting the
welding torch
coolant hoses to
the cooling unit
(TPS 2700)
32
NOTE!
A water-cooled welding torch with an external coolant connection is required for
welding with a TPS 2700 power source and cooling unit.
The coolant flow and return connections must be moved to the front of the cooling unit
(see "Fitting coolant connections to the front of the unit").
Page 33
Connect the red welding torch hose
1
(2) to the coolant return connection on
the cooling unit
Connect the blue welding torch hose
2
(3) to the coolant flow connection on
the cooling unit
EN
33
Page 34
Putting the cooling unit into service
(1)(2)
Safety
General
Filling the cooling unit
WARNING!
Danger from electric current.
An electric shock can be fatal.
Turn the power source mains switch to the "O" position.
▶
Disconnect the power source from the mains.
▶
Ensure that the power source remains disconnected from the mains until all work
▶
has been completed.
NOTE!
The cooling unit is delivered without any coolant.
The coolant is supplied separately in a canister. Fill and bleed the cooling unit before
start-up.
NOTE!
Make sure that no coolant enters the device.
If there is any coolant on the exterior of the device, remove it immediately.
Undo the screw cap on the fill nozzle
1
Pull back the locking ring (1) on the
2
coolant flow connection, disconnect
the coolant hose and let go of the
locking ring (1)
Carefully push back the sealing cone
3
(2) in the centre of the coolant flow
connection using a wooden or plastic
pin (Ø = max. 6 mm / 0.236 in.), until it
audibly engages
Fill with fresh coolant
4
Locking ring on coolant flow connection, sealing cone
inside coolant flow connection
Pull back the locking ring (1) on the coolant flow connection to release the sealing
5
cone (2) and then let go of the locking ring (1)
Connect the coolant flow connection hose to the coolant flow connection
6
Screw the screw cap onto the fill nozzle
7
34
Page 35
Commissioning
the cooling unit
NOTE!
The coolant level and cleanliness of the coolant must always be checked before
commissioning the cooling unit.
Connect the power source to the mains
1
Turn the power source mains switch to the "I" position
2
-The coolant pump starts up
Check the coolant flow until you can see a steady return flow of coolant through the
3
fill nozzle
NOTE!
During welding, check at regular intervals that the coolant is flowing properly.
You should be able to see a steady return flow of coolant through the fill nozzle.
EN
35
Page 36
Care, maintenance and disposal
Safety
WARNING!
Danger due to work that has been carried out incorrectly.
All the work described below must only be carried out by trained and qualified personnel.
Fully read and understand this document.
▶
Fully read and understand all the Operating Instructions for the system components,
▶
especially the safety rules.
WARNING!
Danger from electric current.
An electric shock can be fatal.
Turn the power source mains switch to the "O" position.
▶
Disconnect the power source from the mains.
▶
Ensure that the power source remains disconnected from the mains until all work
▶
has been completed.
After opening the device, use a suitable measuring instrument to check that electric-
▶
ally charged components (e.g. capacitors) have been discharged.
WARNING!
Danger from inadequate ground conductor connection.
This can result in serious injury and damage to property.
The housing screws provide a suitable ground conductor connection for earthing the
▶
housing and must NOT be replaced by any other screws that do not provide a reliable ground conductor connection.
CAUTION!
Danger from hot coolant.
This can result in severe scalds.
Wait until the coolant has cooled down before carrying out any of the activities
▶
described below.
CAUTION!
Risk from coolant leakage.
This can result in serious damage to property.
Make sure that no coolant gets into the device.
▶
If there is any coolant on the exterior of the cooling unit, remove it immediately.
▶
GeneralUnder normal operating conditions, the device requires only a minimum of care and
maintenance. However, it is vital to observe some important points to ensure the welding
system remains in a usable condition for many years.
36
Page 37
Symbols for care
(1)
(2)(3)
(4)
and maintenance
of the cooling
unit
(1)Check coolant level
(2)Change the coolant
(3)Gas purge the cooler
(4)Read operating instructions
The relevant maintenance intervals and
work are described in detail in the following pages.
EN
Maintenance
intervals, maintenance work
At every start-up
CAUTION!
Risk due to start-up without coolant.
This can result in serious damage to property.
If water-cooled system components are operated without coolant, this will normally
▶
result in the failure of the system components.
Fronius shall not be liable for any damage resulting from such action. In addition, no
warranty claims will be entertained.
-Ensure that all the hosepacks, the welding torch and the ground earth connection
are undamaged
-Check that there is an all-round clearance of 0.5 m (1 ft 7.69 in.) to ensure that cooling air can flow in and out freely
-Check the screw connections between all system components for tightness
-Check all the coolant connections of the welding system for tightness
-Monitor the coolant return flow in the coolant container
-If no coolant is returning to the container, identify and remedy the cause
Once a week
-Check coolant level. If the coolant level is below the "min" mark, top up with coolant
-Check the purity of the coolant. Change the coolant if necessary
Risk from non-permitted coolant.
This can result in serious damage to property.
▶
▶
Every 2 months
-If present: Check the coolant filter for dirt and clean if necessary
Every 6 months
-Gas purge the cooler
CAUTION!
Use only original Fronius coolant (Cooling Liquid FCL 10/20 or torch coolant) when
filling the cooling unit.
Other coolants are not recommended for electrical conductivity and material compatibility reasons.
37
Page 38
Every 6 months in 3-shift operation with ethanol-based coolant
(1)
-Gas purge the cooler
-Change the coolant
Every 12 months in single-shift operation with ethanol-based coolant
-Change the ethanol-based coolant
Every 12 months in 3-shift operation with FCL 10/20 coolant
-Change the coolant
Every 24 months in single-shift operation with FCL 10/20 coolant
-Change the coolant
Gas purge the
cooler
Gas purging the cooler:
NOTE!
For the sake of clarity, the cooling unit is shown in the following figures without
the power source.
However, the power source can remain on the cooling unit when gas purging the cooler.
Always follow the instructions in the "Safety" section at the start of the "Care, maintenance and disposal" chapter.
NOTE!
Risk of damage to electronic components.
Do not bring air nozzle too close to electronic components.
-Remove the unit side panels and
clean the cooler (1)
Changing the
coolant
38
If a large amount of dust has accumulated:
-Remove device side panels and clean inside of device with dry reduced compressed
air
Changing the coolant:
NOTE!
The coolant must not be disposed of in the public sewage system.
Dispose of coolant in accordance with the applicable local and national regulations.
NOTE!
Use only original Fronius coolant when refilling the cooling unit.
Undo the screw cap on the fill nozzle
1
Page 39
Place a suitable container underneath the cooling unit drain hose to catch the
(1)(2)
2
coolant
Pull the drain hose out of the upper recess of the cooling unit and hold it in the con-
3
tainer
Remove the drain hose cap
4
Allow the coolant to flow into the container
5
Dispose of used coolant properly
6
Place the cap on the drain hose
7
Return the drain hose to its original position
8
Pull back the locking ring (1) on the
9
coolant flow connection, disconnect
the coolant hose and let go of the
locking ring (1)
Carefully push back the sealing cone
10
(2) in the centre of the coolant flow
connection using a wooden or plastic
pin (Ø = max. 6 mm / 0.236 in.), until it
audibly engages
Fill to the "max" mark with fresh
11
coolant
EN
Locking ring on coolant flow connection, sealing cone
inside coolant flow connection
Pull back the locking ring (1) on the coolant flow connection to release the sealing
12
cone again (2) and then let go of the locking ring (1)
Connect the coolant flow connection hose to the coolant flow connection
13
Screw the screw cap onto the fill nozzle
14
Notes on changing the welding
torch
Excess pressure will damage the cooling unit.
CAUTION!
Before gas purging the welding torch with compressed air, undo the screw cap on the fill
nozzle.
DisposalDispose of in accordance with the applicable national and local regulations.
39
Page 40
40
Page 41
Troubleshooting
41
Page 42
42
Page 43
Troubleshooting
EN
Safety
WARNING!
Danger due to work that has been carried out incorrectly.
This can result in serious injury and damage to property.
All the work described below must only be carried out by trained and qualified per-
▶
sonnel.
Fully read and understand this document.
▶
Fully read and understand all the Operating Instructions for the system components,
▶
especially the safety rules.
WARNING!
Danger from electric current.
An electric shock can be fatal.
Turn the power source mains switch to the "O" position.
▶
Disconnect the power source from the mains.
▶
Ensure that the power source remains disconnected from the mains until all work
▶
has been completed.
After opening the device, use a suitable measuring instrument to check that electric-
▶
ally charged components (e.g. capacitors) have been discharged.
WARNING!
Danger from inadequate ground conductor connections.
This can result in serious injury and damage to property.
The housing screws provide a suitable ground conductor connection for earthing the
▶
housing and must NOT be replaced by any other screws that do not provide a reliable ground conductor connection.
CAUTION!
Danger from hot coolant.
This can result in severe scalds.
Wait until the coolant has cooled down before carrying out any of the activities
▶
described below.
CAUTION!
Risk from coolant leakage.
This can result in serious damage to property.
Make sure that no coolant gets into the device.
▶
If there is any coolant on the exterior of the cooling unit, remove it immediately.
▶
GeneralIf the cooling unit is fitted with one of the following options, the relevant error message
appears on the power source control panel:
-Flow watchdog with coolant filter ... no | H2O (coolant flow error)
-Thermostat ... hot | H2O (coolant temperature too high)
43
Page 44
Fuse-protecting
(1)
(2)
the cooling unit
The cooling unit is protected by three fuses:
-Coolant pump fuse (1) on the front of cooling unit (fuse blows if the coolant pump
becomes overloaded or blocked)
-Two fuses (2) inside the unit, above the fan (fuses blow if there is a short circuit to
earth)
Fuse on front of the unit
Fuses above the fan
TroubleshootingMake a note of the serial number and configuration of the device and contact our After-
Sales Service team with a detailed description of the error, if
-errors occur that are not listed below
-the troubleshooting measures listed are unsuccessful
44
Page 45
Insufficient or no coolant flow
Cause:
Remedy:
Coolant level too low
Top up coolant
EN
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Constriction or foreign body in cooling circuit
Remove constriction or foreign body
Coolant pump fuse defective
Replace coolant pump fuse
Coolant contaminated
Change the coolant
Coolant filter displaced when connecting coolant return
Clean coolant filter using clean tap water or change filter element
Coolant pump is jammed (FK 4000 R, FK 4000 R US and FK 4000 Rob
only)
Turn coolant pump shaft (see operating instructions, "Turning coolant pump
shaft" section). Contact after-sales service if the coolant pump shaft proves
impossible to turn
Coolant pump defective
Contact after-sales service
Permitted duty cycle exceeded
Wait until the end of the coolant pump cooling phase
Cause:
Remedy:
Cause:
Remedy:
Insufficient cooling power
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Flow sensor has tripped, requesting parameter F3 from the welding system
shows that there is nothing flowing through: Coolant pump defective
Contact after-sales service
Flow sensor has tripped, requesting parameter F3 on the power source
shows that there is still a small amount flowing through: coolant hoses
kinked or coolant filter displaced when connecting coolant return
Repair coolant hoses, clean coolant filter using clean tap water or change
filter element
Faulty fan
Contact after-sales service
Coolant pump defective
Contact after-sales service
Cooler contaminated
Gas purge cooler with dry compressed air
Cooling capacity of connected cooling unit not high enough
Use a cooling unit with a greater cooling power
45
Page 46
High operating noise level
Cause:
Remedy:
Coolant level too low
Top up coolant
Cause:
Remedy:
no l H2O
The cooling unit flow sensor has tripped. The error message appears on the power
source control panel.
Cause:
Remedy:
Cause:
Remedy:
hot l H2O
The cooling unit thermostat has tripped. The error message appears on the power
source control panel.
Cause:
Remedy:
Coolant pump defective
Contact After-Sales Service
Coolant flow problem
Check coolant level, cleanliness and proper return;
change coolant if necessary
Coolant filter displaced when connecting coolant return
Clean coolant filter using clean tap water or change filter element
The coolant temperature is too high
Wait until the end of the cooling phase, i.e. until "hot | H2O" is no longer displayed.
If using a ROB 5000 or field bus coupler for robot control: Before resuming
welding, set the "Source error reset" signal.
46
Page 47
Twisting the coolant pump shaft
(2)(1)
EN
Safety
Turning the
coolant pump
shaft
WARNING!
Danger due to work that has been carried out incorrectly.
This can result in severe personal injury and damage to property
All the work described below must only be carried out by trained and qualified per-
▶
sonnel.
Fully read and understand this document.
▶
Fully read and understand all the Operating Instructions for the system components,
▶
especially the safety rules.
WARNING!
Danger from electric current.
An electric shock can be fatal.
Turn the power source mains switch to the "O" position.
▶
Disconnect the power source from the mains.
▶
Ensure that the power source remains disconnected from the mains until all work
▶
has been completed.
Remove the coolant pump fuse (1)
1
Insert a suitable slotted screwdriver
2
from the outside through the coolant
pump shaft bushing (2) and turn the
coolant pump shaft
Contact after-sales service if the
3
coolant pump shaft proves impossible
to turn
Remove the slotted screwdriver
4
Replace the coolant pump fuse (1)
5
47
Page 48
Technical data
GeneralThe cooling capacity of a cooling unit depends on
-Ambient temperature
-Delivery head
-Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
FK 4000
Mains voltage3 x 230 / 400 V AC
Mains voltage tolerance-10% / +10%
Mains frequency50 / 60 Hz
Current consumption0.9 A / 0.6 A
Cooling power at
Q = 1 l/min + 25°C (77°F)
Q = 1 l/ min + 40°C (104°F)
Max. delivery head5 m
Max. delivery rate1.6 l/min
Max. pump pressure4 bar
PumpOscillating armature pump
Pump service lifeapprox. 3,000 hrs
Coolant quantity5.5 l
Protection classIP 23
Dimensions l/w/h725/290/230 mm
1120 W
700 W
16 ft. 5 in.
0.42 gal./min [US]
58 psi
1.45 gal. [US]
28.54/11.42/9.06 in.
FK 4000 R, FK
4000 R FC
48
Weight (without coolant)14.1 kg
31.09 Ib.
Mark of conformityCE
Mains voltage3 x 400 V AC
Mains voltage tolerance-10% / +10%
Mains frequency50 / 60 Hz
Current consumption0.6 A
Cooling power at
Q = 1 l/min + 25°C (77°F)
Q = 1 l/ min + 40°C (104°F)
Max. delivery head33 m
1360 W
870 W
108 ft. 3.24 in.
Page 49
Max. delivery rate3.5 l/min
0.92 gal./min [US]
Max. pump pressure4 bar
58 psi
PumpCentrifugal pump
Pump service lifeapprox. 10,000 hrs
Coolant quantity5.5 l
1.45 gal. [US]
Protection classIP 23
Dimensions l/w/h725/290/230 mm
28.54/11.42/9.06 in.
Weight (without coolant)13.3 kg
29.32 Ib.
Mark of conformityCE
EN
FK 4000 Rob
Mains voltage3 x 400 V AC
Mains voltage tolerance-10% / +10%
Mains frequency50 / 60 Hz
Current consumption0.6 A
Cooling power at
Q = 1 l/min + 25°C (77°F)
Q = 1 l/ min + 40°C (104°F)
Max. delivery head33 m
Max. delivery rate3.5 l/min
Max. pump pressure4 bar
PumpCentrifugal pump
Pump service lifeapprox. 15,000 hrs
Coolant quantity5.5 l
Protection classIP 23
Dimensions l/w/h725/290/230 mm
1360 W
870 W
108 ft. 3.24 in.
0.92 gal./min [US]
58 psi
1.45 gal. [US]
28.54/11.42/9.06 in.
FK 4000 R US
Weight (without coolant)13.3 kg
29.32 Ib.
Mark of conformityCE
Mains voltage200 - 230 / 400 - 460 V AC
Mains voltage tolerance-10% / +10%
49
Page 50
Mains frequency50 / 60 Hz
Current consumption1.3 A / 0.5 A
Cooling power at
Q = 1 l/min + 25°C (77°F)
Q = 1 l/ min + 40°C (104°F)
Max. delivery head33 m
Max. delivery rate3.5 l/min
Max. pump pressure4 bar
PumpCentrifugal pump
Pump service lifeapprox. 10,000 hrs
Coolant quantity5.5 l
Protection classIP 23
Dimensions l/w/h725/290/230 mm
Weight (without coolant)13.3 kg
1360 W
870 W
108 ft. 3.24 in.
0.92 gal./min [US]
58 psi
1.45 gal. [US]
28.54/11.42/9.06 in.
29.32 Ib.
Mark of conformityCSA
50
Page 51
EN
51
Page 52
FRONIUS INTERNATIONAL GMBH
Froniusstraße 1
A-4643 Pettenbach
AUSTRIA