Fronius Ext. I/O for AB Interface Installation Instruction [DE, EN]

/ Battery Charging Systems / Welding Technology / Solar Electronics
EN
Ext. I/O AB Interface
Einbauanleitung
Roboter-Option
Installation instructions
Robot option
42,0410,1864 002-19042013
0
Inhaltsverzeichnis
Allgemeines ............................................................................................................................................... 3
Sicherheit.............................................................................................................................................. 3
Lieferumfang......................................................................................................................................... 3
Benötigtes Werkzeug........................................................................................................................... 3
Print Ext. I/O AB Interface einbauen und aktivieren................................................................................... 4
Print Ext. I/O AB Interface einbauen ..................................................................................................... 4
ROB I/O aktivieren ................................................................................................................................ 5
1
2
Allgemeines
Sicherheit
Lieferumfang (1) Print Ext. I/O für AB Interface
(2) 2 x Kunststoff-Distanz M4 x 10 mm (3) 2 x Kunststoff-Distanz M4 x 30 mm (4) 1 x Metall-Distanz M5 x 10 mm (5) 1 x Metall-Distanz M5 x 30 mm (6) Abdeckblech (7) Abdeckkappe (8) 2 x Kreuzschraube 3,5 x 9,5 mm VZ (9) Diverse Aufkleber
WARNUNG! Ein elektrischer Schlag kann tödlich sein. Vor Öffnen des Gerätes
- Netzschalter in Stellung - O - schalten
- Gerät vom Netz trennen
- ein verständliches Warnschild gegen Wiedereinschalten anbringen
- mit Hilfe eines geeigneten Messgerätes sicherstellen, dass elektrisch gela­dene Bauteile (z.B. Kondensatoren) entladen sind
WARNUNG! Fehlerhaft durchgeführte Arbeiten können schwerwiegende Per­sonen- und Sachschäden verursachen. Nachfolgend beschriebene Tätigkeiten dürfen nur von geschultem Fachpersonal durchgeführt werden! Beachten Sie das Kapitel „Sicherheitsvorschriften“ in der Bedienungsanleitung der Stromquelle und der Systemkomponenten.
Benötigtes Werk­zeug
- Torx-Schraubendreher TX 25
- Kreuz-Schraubendreher
- Stecknuss SW 7 mm, Steckschlüssel
3
Print Ext. I/O AB Interface einbauen und aktivieren
2
Print Ext. I/O AB Interface einbau­en
WICHTIG! Bei Verwendung der externen Versorgungsspannung von US1 oder US2 als
Versorgung des Busmasters, muss das E-Set „Externe Versorgung UBST“ (Artikelnum­mer 4,100,501) verwendet werden.
4 Schrauben (1) lösen und Abdeckung
(1) (1)
(1)(1)
1
entfernen
Kabelbaum des Prints Ext. I/O AB In­terface (2) an den Stecker X7 - Schnitt­stelle 1 (3) anstecken
(3)(2)
Print einsetzen und mit zwei Kunst-
(4)
(5)(4)
4
3
stoff-Distanzen (4) und einer Metall­Distanz (5) befestigen
(7)(6) (6)
Stecker (7) mit zwei Kreuzschrauben
4
3,5 x 9,5 mm (6) am Abdeckblech montieren
ROB I/O aktivie­ren
Software „Servicemodul“ öffnen
1
Im Fenster „Servicemodul“ (Knotenlis-
2
te) den Eintrag „AB Interface“ markie­ren
- Die Schaltfläche „Konfiguration“
Auf die Schaltfläche „Konfiguration“ kli-
3
cken
Es erscheint das Dialogfenster „Configuration Fieldbus“
Auf den Ordner „System Settings“ kli-
4
cken
wird aktiv
Im rechten Anzeigefenster „Configura-
5
tion Fieldbus“ den Eintrag ROB I/0 = „NOT CONNECT“ öffnen
- Es erscheint „Connect“
5
Das Kontrollfeld neben „Connect“ an-
7
6
kreuzen
- Der Eintrag ROB I/O = „NOT CONNECT“ ändert sich in ROB I/ O = „CONNECT“
Doppelklick auf den Eintrag ROB I/O = „CONNECT“
Doppelklick auf „Filter time“
8
- Es erscheint der Anzeigewert für „Filter time“
WICHTIG! Werksseitig ist „Filter time“ auf 30 ms eingestellt. Der Einstellbereich erstreckt sich von 20 bis 200 ms.
HINWEIS! Je höher der Wert, desto sicherer, aber auch umso langsamer wird die Signaländerung.
Bei Bedarf, den Wert für „Filter time“ ändern
9
Stromquelle Aus- und Ein schalten
10
6
Contents
General ...................................................................................................................................................... 9
Safety.................................................................................................................................................... 9
Scope of supply .................................................................................................................................... 9
Tools required....................................................................................................................................... 9
Installing and activating the ext. I/O PC board for the AB interface ........................................................... 10
Installing the ext. I/O PC board for the AB interface ............................................................................. 10
Activating the ROB I/O.......................................................................................................................... 11
EN
7
8
General
Safety
Scope of supply (1) Ext. I/O PC board for AB interface
(2) 2x M4 x 10 mm plastic spacers (3) 2x M4 x 30 mm plastic spacers (4) 1x M5 x 10 mm metal spacer (5) 1x M5 x 30 mm metal spacer (6) Cover plate (7) Cap (8) 2x 3.5 x 9.5 mm cross-head screws (9) Various stickers
WARNING! An electric shock can be fatal. Before opening the device
- Turn the mains switch to the "O" position
- Unplug the machine from the mains
- Put up an easy-to-understand warning sign to stop anybody inadvertently switching it back on again
- Using a suitable measuring instrument, check to make sure that electrically charged components (e.g. capacitors) have discharged
WARNING! Work that is carried out incorrectly can cause serious injury and dam­age. The following activities must only be carried out by trained and qualified per­sonnel. Read the "Safety rules" chapter in the power source and system components operating instructions.
EN
Tools required - TX 25 Torx screwdriver
- Cross-head screwdriver
- 7 mm socket, socket wrench
9
Installing and activating the ext. I/O PC board for the
2
AB interface
Installing the ext. I/O PC board for the AB interface
IMPORTANT! When using the external US1 or US2 supply voltage to supply the bus mas-
ter with power, the "External UBST power supply" I-kit (item number 4,100,501) must be used.
Undo the four screws (1) and remove
(1) (1)
(1)(1)
1
the cover
Plug the cable harness from the ext. I/ O PC board for the AB interface (2) into the X7 plug on interface 1 (3)
(3)(2)
Insert and secure the PC board using
(4)
(5)(4)
10
3
the two plastic spacers (4) and one metal spacer (5)
(7)(6) (6)
Fit the plug (7) to the cover plate using
4
two 3.5 x 9.5 mm cross-head screws (6)
EN
Activating the ROB I/O
The "Field bus configuration" dialog box appears
Open the "Service module" software
1
Select the "AB interface" entry in the
2
"Service module" window (node list)
- The "Configuration" button beco­mes active
Click the "Configuration" button
3
Click the "System settings" folder
4
Open the ROB I/0 = "NOT CONNECT"
5
entry in the right-hand "Field bus confi­guration" display window
- "Connect" appears
11
Select the checkbox next to "Connect"
7
6
- The ROB I/O entry changes from "NOT CONNECT" to "CONNECT"
Double-click the ROB I/O = "CON­NECT" entry
Double-click "Filter time"
8
- The value for "Filter time" appears
IMPORTANT! The factory setting for "Filter time" is 30 ms. It can take any value between 20 and 200 ms.
NOTE! The higher the value, the slower the change in signal, though it will be more secure.
If necessary, change the value for "Filter time"
9
Switch the power source off and on again
10
12
EN
13
FRONIUS INTERNATIONAL GMBH
Froniusplatz 1, A-4600 Wels, Austria
Tel: +43 (0)7242 241-0, Fax: +43 (0)7242 241-3940
Under http://www.fronius.com/addresses you will find all addresses
of our Sales & service partners and Locations
E-Mail: sales@fronius.com
www.fronius.com
www.fronius.com/addresses
Loading...