EMF DATASHEET FOR ARC WELDING POWER SOURCE
EQUIPMENT INFORMATION
Manufacturer Fronius
Model AccuPocket 150 TIG; AccuPocket 150 TIG/230V/Set/EF; AccuPocket 150 TIG/120V/Set/B;
Model Number 4,075,201; 4,075,201,850; 4,075,201,851; 4,075,201,854; 4,075,201,860; 4,075,201,861; 4,075,201,864
Intended use occupational by laymen
BASIC INFORMATION
Applied Regulations Directive 2014/35/EU
Referenced Limits Directive 2013/35/EU, Recommendation 1999/519/EC
Applied Standards EN 62822-1:2016, EN 62822-2:2016
Non-thermal effects need to be considered for the workplace assessment yes no
Thermal effects need to be considered for the workplace assessment yes no
Data based on maximum power source capability
Data based on worst case setting/program
Data based on multiple settings / programs
AccuPocket 150 TIG/100V/Set/nc; AccuPocket 150 TIG/230V/EF; AccuPocket 150 TIG/120V/B;
AccuPocket 150 TIG/100V/nc
COMPLIANCE SUMMARY
Compliance with ELVs for health effects at standardized configurations yes no
Compliance with ELVs for sensory effects at standardized configurations yes no
All values below the Action Levels at the standardized configurations yes no
NON-THERMAL EFFECTS
HEAD
SENSORY EFFECTS HEALTH EFFECTS
Standardized distance 10.00 cm 10.00 cm 10.00 cm 3.00 cm 3.00 cm
EI at standardized distance 0.18 0.18 0.29 0.16 0.38
Required minimum distance 0.50cm 0.50 cm 1.00 cm 1.00cm 0.50 cm
Distance where all EIs fall below 20:% 19.00 cm
Distance where compliance with general public limits is reached: 1.23 m
TRUNK LIMB HAND LIMB THIGH
Revision 1; Date of Issue: 15-Jul-2016