Fronius Cooling Liquid FCL 10 - FCL 20 (US) Safety data sheet [EN]

Page 1/10
Safety Data Sheet
acc. to according to GHS Rev. 8 2019 and OSHA HCS
Printing date 04/26/2022 Reviewed on 04/26/2022
1 Identification
Product identifier
Trade name:
Cooling Liquid FCL 10 Cooling Liquid FCL 20
Article number:
40,0009,0180 / 40,0009,0181 / 40,0009,0196 / 40,0009,0197 40,0009,0182 / 40,0009,0183
Application of the substance / the mixture
Details of the supplier of the safety data sheet
Manufacturer/Supplier: Fronius International GmbH
Fronius Straße 5 A-4642 Sattledt T: +43 7242 241 0
Information department:
welding.techsupport@fronius.com msds.techsupport@fronius.com
Emergency telephone number:
+43 7242 241 0 Available: Mo - Th: 08:00 - 16:00 h (CET) Fr: 08:00 - 12:00 h (CET)
Cooling fluid for corresponding Fronius welding systems
Please contact your regional poison center or emergency call!
2 Hazard(s) identification
Classification of the substance or mixture
The product is not classified, according to the Globally Harmonized System (GHS).
Label elements GHS label elements Hazard pictograms Signal word Hazard statements Classification system: NFPA ratings (scale 0 - 4)
Void
1
0
0
Void
Void
Void
Health = 0 Fire = 1 Reactivity = 0
(Contd. on page 2)
US
54.0.17
Page 2/10
Safety Data Sheet
acc. to according to GHS Rev. 8 2019 and OSHA HCS
Printing date 04/26/2022 Reviewed on 04/26/2022
Trade name:
Cooling Liquid FCL 10 Cooling Liquid FCL 20
(Contd. of page 1)
HMIS-ratings (scale 0 - 4)
HEALTH
FIRE
REACTIVITY
Other hazards Results of PBT and vPvB assessment PBT:
The mixture does not contain PBT substances 0,1 %.
vPvB:
3 Composition/information on ingredients
Chemical characterization: Mixtures Description:
Dangerous components:
[% (w/w)]
CAS: 57-55-6 Propylene glycol 20 – 40%
The mixture does not contain vPvB substances 0,1 %.
0
Health = 0 Fire = 1
1
Reactivity = 0
0
Mixture of the substances listed below with nonhazardous additions.
4 First-aid measures
Description of first aid measures General information:
Seek medical treatment in case of complaints. If unconscious, use a stable lateral position and do not administer anything through mouth.
After inhalation: After skin contact:
Supply fresh air; consult doctor in case of complaints.
Generally the product does not irritate the skin.
After eye contact:
Rinse opened eye for several minutes under running water. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical treatment in case of complaints.
After swallowing:
Rinse out mouth and then drink plenty of water. Seek medical treatment.
Most important symptoms and effects, both acute and delayed
No further relevant information available.
Indication of any immediate medical attention and special treatment needed
Depending on the condition of the patients, the doctor must assess the symptoms and the overall general condition.
(Contd. on page 3)
US
54.0.17
Page 3/10
Safety Data Sheet
acc. to according to GHS Rev. 8 2019 and OSHA HCS
Printing date 04/26/2022 Reviewed on 04/26/2022
Trade name:
Cooling Liquid FCL 10 Cooling Liquid FCL 20
(Contd. of page 2)
5 Fire-fighting measures
Extinguishing media Suitable extinguishing agents:
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
For safety reasons unsuitable extinguishing agents: Special hazards arising from the substance or mixture
Formation of toxic gases is possible during heating or in case of fire.
Advice for firefighters Protective equipment:
Wear self-contained respiratory protective device. Wear fully protective suit.
Additional information
Cool endangered receptacles with water spray.
6 Accidental release measures
Personal precautions, protective equipment and emergency procedures
Restricted access to the affected area until cleaning work is completed. Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation Avoid contact with skin and eyes. Avoid breathing mist/vapours/spray.
Environmental precautions:
Do not allow to enter sewers/ surface or ground water.
Methods and material for containment and cleaning up:
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Dispose of the collected material according to regulations.
Protective Action Criteria for Chemicals
Water with full jet
PAC-1:
CAS: 57-55-6 Propylene glycol 30 mg/m³
CAS: 95-14-7 benzotriazole 1.2 mg/m³
PAC-2:
CAS: 57-55-6 Propylene glycol 1,300 mg/m³
CAS: 95-14-7 benzotriazole 13 mg/m³
PAC-3:
CAS: 57-55-6 Propylene glycol 7,900 mg/m³
CAS: 95-14-7 benzotriazole 77 mg/m³
Reference to other sections
See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. See Section 13 for disposal information.
(Contd. on page 4)
US
54.0.17
Loading...