42,0410,2568 007-10112022
(PzS, GiS, ..):
WARNING! Incorrect operation can cause serious injury and damage. Observe battery manufacturer’s instructions. When parameters are being set, make sure that battery is disconnected from charger.
Overheated battery and high charging voltage can cause serious injury and damage. When using the „formatting“ or „deep discharge“ characteristics, disconnect battery from the vehicle, always supervi-
se the battery and disconnect it from the charger, if a battery temperature of 60 °C (140 °F) is exceeded.
6 Ri - WET RiUPoTC 5-12 [7-8] X X X 2.4 (Ri-compens.) X intelligent X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
1 IUI - WET IUIoTC X 12-25 [20] 5 X 2.35-2.50 [2.40] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
Number Name Type Charging Time I1 (A/100Ah) I2 (A/100Ah) I3 (A/100Ah) U1 (V/Cell) Charging Factor Cut-Off Criterion Ch.Fac.Calib. (%) Trickle Charge
Characteristics | Settings
Battery Pb - WET
3 IU - WET IUoTC X 12-25 [20] X X 2.35-2.45 [2.40] X dI/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
8 Charging Factor - WET¹ IUIoTC X 12-25 [20] 5 X 2.35-2.45 [2.40] 1.10-1.25 [1.20] charging factor 95-100 [100] I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
9Buff ering - WET² IUoTC X 30 X X 2.35-2.45 [2.40] X X X Uconst
11 Formatting - WET⁴ IUIoTC X 40 4 X 2.4 X fi xed time X IU-Puls
30 FCC IUI - WET⁵ IUIoTC X 20-40 [35] 5 X 2.35-2.45 [2.40] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
13 I-Puls - WET IUPIPoTC X 12-25 [25] 4 X 2.35-2.45 [2.40] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
10 Deep discharge - WET³ IUoTC 120 2 X X 2.6 X fi xed time X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
2 IUI - GEL IUIoTC X 10-20 [15] 1.2 X 2.30-2.45 [2.35] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
20 Formatting2A - WET⁴ IUIoTC X 40 4 X 2.4 X fi xed time X Iconst
Battery Pb - GEL (PzV, GiV, ..):
4 IU - GEL IUoTC X 10-20 [15] X X 2.30-2.40 [2.35] X dI/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
12 Formatting - GEL⁴ IUIoU X 40 3 X 2.35 X fi xed time X Uconst
33 Buff ering - GEL² IUoU X 25 X X 2.30-2.40 [2.35] X X X Uconst
34 Deep discharge - GEL³ IUoTC 30 4 X X 2.35 X fi xed time X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
39 Tab Traction Gel IUIoTC X 15 1.3 X 2.35 X dU/dt X IU-Puls
40 Exide Motive Power Gel IUIoTC X 15 1.3 X 2.4 X dU/dt X IU-Puls
31 IUI - CSM - WET IUIoTC X 12-25 [25] 5 X 2.35-2.45 [2.40] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
41 Sunlight MotionGel IUIoTC X 15 1.3 X 2.4 X dU/dt X IU-Puls
28 FCC IUI - CSM - WET⁵ IUIoTC X 25-40 [35] 5 X 2.35-2.45 [2.40] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
Battery Pb - CSM - WET (Copper Strained Metal):
32 Deep discharge - CSM - WET³ IUoTC 120 2 X X 2.6 X fi xed time X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
35 IUI - PzQ - WET IUIoTC X 12-25 [25] 5 X 2.35-2.45 [2.40] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
36 FCC IUI - PzQ - WET⁵ IUIoTC X 25-40 [35] 5 X 2.35-2.45 [2.40] X dU/dt X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
Battery Pb - PzQ - WET:
25 EVFJ - Lead Crystal IIIUoU X 20 10 5 2.45 X current @ U1 X Uconst, OFF
Battery Lead Crystal (EVFJ, CNFJ):
26 CNFJ - Lead Crystal IIUoU X 30 15 X 2.47 X current @ U1 X Uconst, OFF
Battery NiCd:
37 Deep discharge - PzQ - WET³ IUoTC 120 2 X X 2.6 X fi xed time X I-Puls, IU-Puls, Uconst, OFF [IU-Puls]
14 IU - NiCd IUoTC X 10-25 [20] X X 1.40-1.75 [1.65] X dl/dt X Uconst, OFF [Uconst]
42 TagID guided charging X 5-12 X X X X X intelligent X IU-Puls
Trickle charge ............................................. is intended for stand-by batteries, starter batteries, batteries with parallel consumers (Power supply for waggons, trains, ..., Charging of batteries for Solar plants, boats)
Charging factor ........................................... Adjustable overcharging of the battery
Battery Pb - WET (PzS,GiS, ..) | Pb - GEL (PzV, GiV, ..):
1)
2)
3)
Deep discharge .......................................... Use only for deep discharged batteries (Battery voltage below the normal operating range) or reactivation charge
Formatting .................................................. Initial charge of the battery (formatting charge)
FCC ........................................................... Fast Charging Curves requires temperature controlled charging
Values in brackets are preset standard values | Valid from CHARGE CONFIG V 1.8.1
4)
5)

Serial Number Additional Information:
Item Number:
Main Software Version:
Option box Battery cooled down
LED strip External air pump
Floor bracket Charge 80 %
Wall bracket Charge in progress
Airfi lter On
„Mobile“ kit Refi ll indicator
Electrolyte circulation Aquamatic
External start/stop Charge fi nish
Charging lights Common error message
Temperature controlled charging Immobiliser
Relay board Main charge fi nished
Battery
Factory setting for this device:
Name Type Charging Time I1 (A/100Ah) I2 (A/100Ah) I3 (A/100Ah) U1 (V/Cell) Charging Factor Cut-Off Criterion Ch.Fac.Calib. (%) Trickle Charge
Equalisation Charge ON OFF
Options: Confi guration Relay Board or Option Box: Relais 1 Relais 2 Relais 3 Relais 4
RCS remote indication