Fronius Acctiva Professional 35A Datasheet [EN]

42
Technical data
Electrical data in­put 230V
Standards 230V
Electrical data in­put 120 V
Standards 120V
Mains voltage ~ 230 V AC, +/- 15 % Mains frequency 50 / 60 Hz Mains current max. 9 A eff. Mains fuse protection max. 16 A Efficiency max. 96 % Effective power max. 1120 W Power consumption (standby) max. 2.4 W Protection class I (with PE conductor) Maximum permitted mains impedance at the interface
(PCC) to the public grid
None
EMC emission class A Marks of conformity CE
IEC 60068-2-6 Sine oscillations (10 - 150 Hz; 1.5 h / axis) IEC 60068-2-29 Repetitive shock (25 g / 6 ms / 1000 shocks) EN 60335-1 EN 60335-2-29 EN 61000-6-2 EN 61000-6-3 (Class A) EN 62233 EMF Standard
Mains voltage ~ 120 V AC ±15% Mains frequency 50/60 Hz Mains current max. 16 A eff. Mains fuse max. 20 A Efficiency max. 94.5% Effective power max. 1120 W No-load power consumption max. 7.8 W Protection class (with ground conductor) I Maximum permitted mains impedance at the interface
(PCC) to the public grid
none
Mark of conformity cTÜVus EMC device class A
UL1236 C22.2 No 107.1-01 FCC CFR 47 Part 15 (Class A)
43
EN
Electrical data output
Battery data
Technical data
Environmental conditions
IEC 60068-2-6 Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; accelera-
tion 5 g)
IEC 60068-2-29 Repetitive shock (25 g / 6 ms / 1000 shocks)
Nominal output voltage 6 V / 12 V / 24 V DC Output voltage range 2 V - 34 V Output current 35 A at 28.8 V DC
35 A at 14.4 V DC 35 A at 7.2 V DC
Battery return current < 1 mA
6 V / 12 V / 24 V DC 3 - 350 Ah
Cooling Convection and fan Dimensions l x w x h 270 x 168 x 100 mm Weight (without cable) 2 kg
Operating temperature -20 °C - +40 °C (>30 °C derating) Storage temperature -40 °C - +85 °C Climate class B Degree of protection IP40
Loading...