30
Mains voltage (+/- 15%)
Acctiva Professional Flash 230 V AC, 50/60 Hz
Acctiva Professional Flash AUS 240 V AC, 50/60 Hz
Acctiva Professional Flash JP 100 V AC, 50/60 HZ
Acctiva Professional 30A JP 100 V AC, 50/60 HZ
Nominal output max.
Acctiva Professional Flash 1080 W
Acctiva Professional Flash AUS 1080 W
Acctiva Professional Flash JP 1080 W
Acctiva Professional 30A JP 710 W
Charging voltage 12.0 - 15.5 V
Charging current I2 (adjustable)
Acctiva Professional Flash 2 - 50 A
Acctiva Professional Flash AUS 2 - 50 A
Acctiva Professional Flash JP 2 - 50 A
Acctiva Professional 30A JP 2 - 30 A
Boost mode charging current t
2 max
(tI
2 max
= 30 s, tI2 = 60 s)
Acctiva Professional Flash max. 70 A
Acctiva Professional Flash AUS max. 70 A
Acctiva Professional Flash JP max. 70 A
Acctiva Professional 30A JP max. 30 A
Nominal charging capacity 10 - 250/300 Ah
Number of cells 6
Charging characteristic IUoU / IUa / IU
Operating temperature * 0°C to +60°C
32°F to 140°F
Storage temperature -20°C to +80°C
4°F to 176°F
Interface USB
Climate class (EN50178) B
EMC Class
Acctiva Professional Flash IEC/EN 61000-6-4/2 (EMC class A)
Acctiva Professional Flash AUS IEC/EN 61000-6-4/2 (EMC class A)
Acctiva Professional Flash JP IEC/EN 61000-6-4 (EMC class A)
Acctiva Professional 30A JP J 55014
Protection IP 21
Marks of conformity see charger rating plate
Weight inclusive of mains and charger leads 6.5 kg
14.33 lb.
Dimensions w x h x d 315 x 200 x 110 mm
12.40 x 7.87 x 4.33 in.
Acctiva
Professional
Flash
Acctiva
Professional
Flash AUS
Acctiva
Professional
Flash JP
Acctiva
Professional
30A JP
Technical data
* If the ambient temperature rises to above 35°C (95°F) or thereabouts (depending on
secondary voltage), the secondary output current is reduced (power derating)