![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg1.png)
FROMM STRETCH
Technical training FS3xx
Models 2009
5/12/2010
1
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg2.png)
FS 3xx Models 2009 32.1xxx.xxx
2
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg3.png)
OP 1 Electrical box 16.8601
N43.9161
RED UNDERLINED PARTS ARE
ADVISED SPAREPARTS
3
5/12/2010
Light machine
under tension
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg4.png)
OP 1 Electrical box 16.8601
Start
Reset
4
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg5.png)
OP 1 Electrical box 16.8601
Movement carriage up.
Movement carriage down.
Manual movement turntable. (JOG Function)
Information button / Alarm indicator
5
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg6.png)
OP 1 Electrical box 16.8601 Update software 1.1
Software Version 1.1 or Higher!
Press shortly LED start = OFF = Auto Program
Press shortly LED start = Blinking = Manual Pr
6
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg7.png)
OP 1 Electrical box 16.8601
Parameter settings / Press for 5 sec - & +
Lower value
5/12/2010
7
Higher value
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg8.png)
OP 1 PARAMETERS
Written PA
Write 16 using
Write 07 using
Confirm
Confirm
Confirm
8
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bg9.png)
OP 1 PARAMETERS
Blinking P01
Next P press
Found correct P select start
Display shows value
9
5/12/2010
Change using
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
Confirm
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bga.png)
OP 1 PARAMETERS
At any moment press STOP to exit
Check the technical manual for the complete parameter list
10
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bgb.png)
OP 1 PARAMETERS
Carriage move upwards after stop
Parameter Description Set /range
P1 Buzzer 1=On/ 0=Off def. 1
P2 Alarm RL1 / External flash light 1=On/ 0=Off def. 1
P3 No option / Remote control / Horse shoe 1=No option 2=Remote control 3=Horse shoe (def=1)
P4 Pallet detect Error E1 1=On/ 0=Off def. 1
P5 Bottom wraps 0 -9 Default 2
P6 Photocell delay 00-40 set 10 (=1 sec) Software 1.0
00-90 set 40 (=1 sec) Software 1.1 or Higher
P8 Cycle selection Program 1 / Program 2 1-2 (def. 1) (See manual machine)
P9 Topwraps 0 -9 Default 2
P10 Joystick function 1=On/ 0=Off def. 0 (From software version 1.1)
P11 Not active
P12 Maintenance counter
1°2° numbers
P13 Maintenance counter
3°4° numbers
P14 Maintenance counter
5°6° numbers
P15 Maintenance counter
7°8° numbers
P16 Speed turntable 30-60 default 40 (Increase with steps of 9)
Def. 00
Def. 06
Def. 16
Def. 00
5/12/2010
11
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bgc.png)
OP 2 Electrical box 16.8602
N43.9160
12
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
Light machine
under tension
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bgd.png)
OP 2 Electrical box 16.8602
Start
Reset
13
5/12/2010
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009
![](/html/c0/c04e/c04e4607ce36794ffdc181b1119cdd02f52256b1273b8fdc3c6b8b5bd98e692d/bge.png)
OP 2 Electrical box 16.8602
Light ON if function has been selected
Display
Higher value
Lower value
Selector to change value’s for speed
14
5/12/2010
Information for maintenance counter!
FROMM Stretch Wrapping Division, Caprino V.se. (VR) Italy
V05 28/05/2009