FROG Leap Twin Instruction Manual

®
FROG® Leap® Twin
Instruction Manual
Mineral Pool-Care System
for Pools up to 40,000 Gallons
Cleaner
because it kills bacteria two ways
Clearer
because it helps keep pH in range
Softer
because it reduces chlorine use up to 50%*
Easier
with pre-lled pacs for no mess,
no guess and no stress
FROG Leap Twin comes with the
FROG Leap Anti-Bac Mineral Pac
Patented Mineral Disinfectant
Customer Service 800-222-0169
frogproducts.com
®
Ver la versión en español de este manual en www.frogproducts.com/product/frog-leap-twin
WARNING
To minimize the risk of serious injury, death or damage, before installing or first using this equipment, read Instruction Manual and all safety labels and follow all safety instructions and precautions. Save manual for future reference.
1
TABLE OF CONTENTS
FROG Leap Twin Infuzers Introduction 3
Notes and Safety Information 4
®
Safety Labels on Infuzers
Installation Tips to Ensure Proper Performance 6
Base Flex-Hose Installation 7
Hard-Plumbed Installation 8
Step 1: Preparing the Pool 9-10
Step 2: Putting the System to Work 11
Step 3: Setting the Control Dial 12
Step 4: Routine Pool Care 13
5
Replacing FROG Leap Anti-Bac Mineral Pac 14
Using FROG Leap Pool Wake Up!
®
Using FROG Leap ALL-OUT
Using FROG Leap Torpedo Pac
16
®
®
17-18
15
Winterizing 19
Troubleshooting 20
Parts List 21
Maintenance - Replacing Control Dial O-Rings 22
Maintenance - Replacing Cap O-Rings and Knobs 22
Warranty 23
For information on King Technology’s entire product line, visit our website at frogproducts.com
2
Welcome to easier pool care courtesy of FROG Leap Twin. With FROG Leap Twin, your pool water will look and feel better without a lot of work or a lot of chlorine. This system† controls bacteria using a combination of minerals and reduced chlorine levels. Chlorine lasts 2X longer with FROG Leap Twin Mineral System.*
There are 4 main parts to the FROG Leap Twin System:
1. FROG Leap Twin Infuzers
2. FROG Leap Anti-Bac Mineral Pac
3. FROG Leap Pool Wake Up!/Pool Hibernation®
4. FROG Leap Torpedo Pac
Part 1 - FROG Leap Twin Infuzers
The water treatment center that controls the ow of water to each part of the FROG Leap Twin System.
FROG Leap
Mineral Infuzer
For any pool up to 40,000 gallons
Product # 01-01-7850
FROG Leap
Chlorine Infuzer
Part 2 - FROG Leap Anti-Bac Mineral Pac
Holds the minerals and ts inside the FROG Leap Twin Mineral Infuzer. Product # 01-12-7852
THE FROG LEAP ANTI-BAC MINERAL PAC MUST BE REPLACED EVERY SIX MONTHS OR AFTER ONE POOL SEASON WHICHEVER IS SHORTER.
Part 3
FROG Leap Pool Wake Up!/Pool Hibernation
Three-step pool opening and closing kit with an Algae Protection Guarantee. Product # 01-10-7858.
FROG Leap Reveille®, FROG Leap Depth Charge® and FROG Leap ALL-OUT
FROG Leap Anti-Bac Mineral Pac comes inside the FROG Leap Twin Mineral Infuzer and is also sold separately.
Also sold separately: FROG Leap Torpedo Pac, FROG Leap ALL-OUT (Product # 01-10-7872) and
FROG Leap Mineral System consists of the FROG minerals silver chloride and carbonate used in conjunction with 0.5 ppm chlorine.
The FROG Leap Anti-Bac Mineral Pac must be used in conjunction with the FROG Leap Torpedo Pac (EPA Reg. No.: 53735-2),
an EPA registered chlorine pool product or a chlorine delivery device.
*Compared to the minimum EPA recommended chlorine level of 1.0 ppm for a stabilized swimming pool.
Part 4
FROG Leap 4 lb. Torpedo Pac
Pre-lled with chlorine tablets and ts inside the FROG Leap Twin Chlorine Infuzer. Product # 01-03-7833
FROG Leap Pool Wake Up!/Pool Hibernation.
3
Notes and Safety Information
General Notes
These instructions contain information for the safe and proper
operation of these Infuzers. Observe the following principles:
• Ensure that everyone using these Infuzers follows the instructions and safety precautions.
• Keep the instructions nearby and available for reference
throughout the service life of these Infuzers.
These instructions do not provide for every possible contingency
that might be encountered in connection with installation, opera-
tion or maintenance of this equipment. Should further informa-
tion be desired or should particular issues arise which are not
covered sufciently in this manual, contact King Technology at
800-222-0169.
Explanation of the signal words
Signal words, which depict the probability and severity of harm, are used in these instructions. They are dened as follows:
Signal Word
DANGER
WARNING
Meaning
Indicates an imminently hazardous situation which, if not avoided, will result in death, serious injury or major property damage.
Indicates a hazardous situation which, if not avoided, could result in serious injury, death, or major property damage.
NOTICE
Indicates special instructions that are important but not related to physical injury hazards.
Explanation of the safety pictographs
The following pictographs illustrate the type of hazard.
Pictograph Type of Danger
Safety Alert/General Hazard
Explosion Risk
Hazardous Pressure
Flammable Fire Hazard
Identication of warnings
Warnings are intended to help you recognize risks and avoid
death, injury or property damage. This is how warnings are identied:
Signal Word
Pictographs
Description of danger.
Consequences if ignored.
a The arrow signals a safety precaution to be taken to
eliminate or reduce the risk.
4
Safety Label on Infuzers
Review this label before installing or operating this system. Contact King Technology at 800-222-0169 if this label is missing from your FROG Leap Twin Infuzers.
Fire, explosion and high pressure hazards
To minimize the risk of serious injury, death or property damage while using the FROG Leap Twin Infuzers:
a Read, understand and follow all instructions and safety precautions in the manual, and on these FROG Leap Twin Infuzers and on any label for chemicals used with this system including FROG Leap Torpedo Pacs, FROG Leap Anti-Bac Mineral Pacs and FROG Leap Pool Wake Up!/
Pool Hibernation (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT.)
DANGER
a Never use fast dissolving chlorine tablets, liquid bleach, or calcium hypochlorite in the FROG Leap Twin Infuzers.
a Never mix Trichlor chlorine tablets with Calcium Hypochlorite, or with any other form of concentrated chlorine or other chemicals.
a Never add any other types of chlorine, pH adjusters, shock treatments or algaecides through the skimmer.
These products should be added directly into the pool if required.
a Do not contaminate the FROG Leap Twin Infuzers, FROG Leap Anti-Bac Mineral Pac, FROG Leap Torpedo Pac and FROG Leap Pool Wake Up!/Pool Hibernation (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT) with dirt, organic matter, pool chemicals (such as calcium hypochlorite or pool shocks), fertilizers or other household chemicals. Contact between any of these substances and the FROG Leap Twin Infuzers including FROG Leap Anti-Bac Mineral Pac, FROG Leap Torpedo Pac, FROG Leap Pool Wake Up!/Pool Hibernation (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT) will result in a chemical reaction with the generation of heat, liberation of hazardous gasses and re or explosion.
WARNING
a Use only FROG Leap Torpedo Pacs, FROG Leap Anti-Bac Mineral Pacs, FROG Leap Pool Wake Up!/Pool Hibernation (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT) in the FROG Leap Twin Infuzers. Never use bulk chemicals.
a To prevent the build up of gas pressure in the FROG Leap Twin Infuzers, be sure the pool return line valves are open – except when opening or servicing the unit.
a Do not inhale fumes from the FROG Leap Twin Infuzers or FROG Leap Torpedo Pac.
a Avoid sparks, smoking, or any open ame near FROG Leap Twin Infuzers or chemicals.
a Do not exceed maximum operating pressure of 50 psi or maximum temperature of 104º F.
a Do not remove the cap while under pressure. Always turn off pump and bleed off pressure before opening FROG Leap Twin Infuzers.
a Do not install automatic or fast shut off valves downstream of FROG Leap Twin Infuzers.
a Always install the FROG Leap Twin Infuzers AFTER a heater (if applicable) on the return line.
a Always install any additional sanitizing equipment AFTER and NEVER BEFORE the FROG Leap Twin Infuzers are installed on the return line.
a Do not permit children to use or climb on this product. This product must be positioned to prevent children from using it as a means of access
to the pool.
a Always stand clear of the FROG Leap Twin Infuzers during pump start-up.
a Replace FROG Leap Twin Infuzers if you see signs of cracks, damage or degradation to the Infuzers bodies or caps.
NOTICE
a Prior to pressurizing, check with your dealer to ensure your plumbing connections meet building codes. a Failure to properly winterize your FROG Leap Twin Infuzers could result in freeze damage. (See page 19 for winterizing details.)
5
Installation Tips to Ensure Proper Performance
Before installing, read all directions carefully and contact your dealer for installation support.
WARNING
• Do not exceed maximum operating pressure of 50 psi.
• Do not install automatic or fast shut off valves downstream of feeder.
• Always install the FROG Leap Twin Infuzers AFTER the heater (if applicable) on the return line.
• Always install any additional sanitizing equipment AFTER and NEVER BEFORE the FROG Leap Twin Infuzers are installed on the return line.
1) If using a multi-speed pump, run pump for at least 6 hours per day at high speed (at least 40 gpm).
If the pump will run on low speed 24 hours per day or less than 6 hours per day on high speed, you must bleed the air while the pump is on by unscrewing both Infuzer back knobs until water appears from both Infuzers. Then screw the knob back in. Repeat this process each time the cap is removed for any reason.
A. With High Flow Rate (greater than 80 gpm)
FROG Leap Twin Infuzers
Install T-ttings exactly as shown.
B. With In-Floor Cleaner - TWO OPTIONS
OPTION 1- A Two-Line Installation
The best option is to have two lines. One line with pump, lter, heater and
FROG Leap Twin Infuzers and a second line with a separate pump for the in-oor cleaning system (lter optional).
FROG Leap Twin Infuzers
POOL RETURN
Line 1
PUMP
FILTER
HEATER
2) Install system with 4-8 psi back pressure.
Lower back pressures could result in under chlorination. Change the eyeball ttings in the return jets to a smaller size to increase back pressure. Contact King Technology at 800-222-0169 for a specially designed Infuzer pressure gauge to determine back pressure at pool start-up.
3) Special installation Requirements:
IMPORTANT: Over chlorination or damage to the FROG
Leap Twin Infuzers or other equipment could result if special installations A, B or C are not used in these situations.
If water ow is higher than 80 gallons per minute (gpm), see diagram A.
If an in-oor cleaner is included with pool, see diagram B, with two options. Preferred installation is Option 1 with two separate lines.
If set-up is a pool and spa combination with common equipment, see diagram C.
Line 2
FILTER
PUMP
OPTION 2 - A 3-Way Valve Installation
3-way manual valve or 3-way motor valve plus controls
FROG Leap Twin Infuzers
PUMP
FILTER
C. Pool and Spillover Spa Combination
IN-FLOOR
CLEANER VALVE
POOL WATER LEVEL
IN-FLOOR CLEANER VALVE
Questions? Call Customer Service at 800-222-0169 Monday thru Friday, 8 am to 5 pm central standard time.
6
FROG Leap Twin Infuzers
Install
TOOLS NEEDED
Screwdriver
Pipe Wrench
MATERIALS NEEDED
Pipe Thread Tap e or Sealant
Two hose adapters 1½” x 1½” x 1¼”
Two Sections of 1½” or 1¼” Flex Hose
Base Flex-Hose Installation
Apply pipe thread tape or
1. 2.
sealant to the threaded end of both hose adapters.
Screw adapters into each end of the FROG Leap Twin Infuzers. Hand tighten. Finish tightening by turning 1 to 2 revolutions with a pipe wrench. DO NOT OVER TIGHTEN.
The FROG Leap Twin Infuzers should always be installed between the lter and pool (or between heater and pool if applicable).
Never install FROG Leap Twin Infuzers before the heater or damage to the heater could occur.
Two Hose Clamps
RECOMMENDED
4-8 psi Back Pressure
To avoid over or under chlorination, replace eyeball ttings in the return jets to a smaller or larger size to adjust back pressure. For best results use King Technology’s pressure gauge, order part number 01-22-4000.
Attach the lter section of ex hose to one
3.
hose adapter and the return section of ex hose to the other hose adapter with clamps and tighten with screwdriver. Bi-ow valve design allows water ow in either direction.
To prevent damage to
4.
heaters or lters, see your
FILTER & PUMP
dealer about installing a
corrosion resistant check valve which will reduce the
back ow of chlorine gas when the FROG Leap Twin Infuzers are turned off.
HOSE CLAMP
CHECK VALVE
1 1/2” X 1 1/2” X 1 1/4” HOSE ADAPTER
1 1/2” OR 1 1/4” FLEX HOSE
HOSE ADAPTER
HOSE CLAMP
HOSE ADAPTER
HOSE CLAMP
TO POOL
For better stability, FROG Leap Twin
5.
Infuzers may be mounted on a treated wood base using Phillips pan head screws, one in front and two in back. If you have questions about stability, please contact your dealer or King Technology.
7
TOOLS NEEDED
Pipe Wrench
Hacksaw
Tape Measure
MATERIALS NEEDED
Pipe Thread Tape or Sealant, Primer and PVC Cement
Hard-Plumbed Installation
The FROG Leap Twin Infuzers should always be installed between the lter and pool (or between heater and pool if applicable). Never install FROG Leap Twin Infuzers before the heater or damage to the heater could occur.
Do NOT install in copper pipe if using FROG Leap Torpedo Pac as chemical corrosion may lead to pipe failure.
Minimum 12” above opening
Minimum 12” above opening
P
C
P
V
r
r
e
i
m
C
e
e
m
1½” Male Adapter (slip x MPT)
or
2” Female Adapter (slip x FPT)
SECURE INFUZER
Minerals Chlorine
t
n
Do NOT install FROG Leap Twin Infuzers off-line.
Screw adapters into each end of FROG Leap Twin Infuzers following
1.
2.
directions for a male adapter or a female adapter. Hand tighten.
Install with water owing through the minerals rst and then the chlorine.
Finish tightening by turning 1 to 2 revolutions with a pipe wrench.
DO NOT OVER TIGHTEN.
If using Male adapters,
1a. 1b.
apply pipe thread tape or sealant to the threaded end of each.
Minimum 12” to side
Allow a minimum of 12” above and on each side of FROG Leap Twin Infuzers to ensure room for easy replacement of FROG Leap Anti-Bac Mineral Pac and FROG Leap Torpedo Pac.
If using Female adapters, apply pipe thread tape or sealant to the threaded end of each.
Minimum 12” to side
Measure the distance
2.
between outside male adapters and cut out a section of pipe 3” less than that dimension.
For better stability, FROG Leap Twin Infuzers may be
P
r
i
mounted on a treated wood base using
Phillips pan head screws, one in front
and two in back. If you have questions about stability, please contact your dealer or King Technology.
Following Primer directions, brush Primer on
3. 4.
the inside of the adapters and to ends of pipe. Repeat this process with PVC cement following manufacturer’s directions on that product.
To prevent damage to heaters or
5.
lters, see your dealer about installing a corrosion resistant check valve which will reduce the back ow of chlorine gas when the FROG Leap Twin Infuzers are turned off.
8
r
e
m
P
C
V
C
t
n
e
e
m
Insert PVC pipe into adapters with a twisting action. Hold in place 5 to 10 seconds to bond.
Loading...