WARNING
To minimize the risk of serious injury, death or
damage, before installing or first using this
equipment, read Instruction Manual and all safety
labels and follow all safety instructions and
precautions. Save manual for future reference.
1
TABLE OF CONTENTS
FROG Leap Twin Infuzers Introduction 3
Notes and Safety Information 4
®
Safety Labels on Infuzers
Installation Tips to Ensure Proper Performance 6
Base Flex-Hose Installation 7
Hard-Plumbed Installation 8
Step 1: Preparing the Pool 9-10
Step 2: Putting the System to Work 11
Step 3: Setting the Control Dial 12
Step 4: Routine Pool Care 13
5
Replacing FROG Leap Anti-Bac Mineral Pac 14
Using FROG Leap Pool Wake Up!
®
Using FROG Leap ALL-OUT
Using FROG Leap Torpedo Pac
16
®
®
17-18
15
Winterizing 19
Troubleshooting 20
Parts List 21
Maintenance - Replacing Control Dial O-Rings 22
Maintenance - Replacing Cap O-Rings and Knobs 22
Warranty 23
For information on King Technology’s entire product
line, visit our website at frogproducts.com
2
Welcome to easier pool care courtesy of FROG Leap
Twin. With FROG Leap Twin, your pool water will
look and feel better without a lot of work or a lot
of chlorine. This system† controls bacteria using a
combination of minerals and reduced chlorine levels.
Chlorine lasts 2X longer with FROG Leap Twin
Mineral System.*
There are 4 main parts to the FROG Leap Twin
System:
1. FROG Leap Twin Infuzers
2. FROG Leap Anti-Bac Mineral Pac
3. FROG Leap Pool Wake Up!/Pool Hibernation®
4. FROG Leap Torpedo Pac
Part 1 - FROG Leap Twin Infuzers
The water treatment center that controls the ow of water
to each part of the FROG Leap Twin System.
FROG Leap
Mineral Infuzer
For any pool up to 40,000 gallons
Product # 01-01-7850
FROG Leap
Chlorine Infuzer
Part 2 - FROG Leap
Anti-Bac Mineral Pac
Holds the minerals and ts
inside the FROG Leap Twin
Mineral Infuzer.
Product # 01-12-7852
THE FROG LEAP ANTI-BAC
MINERAL PAC MUST BE
REPLACED EVERY SIX MONTHS
OR AFTER ONE POOL SEASON
WHICHEVER IS SHORTER.
Part 3
FROG Leap Pool Wake Up!/Pool Hibernation
Three-step pool opening and closing kit with an Algae
Protection Guarantee. Product # 01-10-7858.
FROG Leap Anti-Bac Mineral Pac comes inside the FROG Leap Twin Mineral Infuzer and is also sold separately.
Also sold separately: FROG Leap Torpedo Pac, FROG Leap ALL-OUT (Product # 01-10-7872) and
†
FROG Leap Mineral System consists of the FROG minerals silver chloride and carbonate used in conjunction with 0.5 ppm chlorine.
The FROG Leap Anti-Bac Mineral Pac must be used in conjunction with the FROG Leap Torpedo Pac (EPA Reg. No.: 53735-2),
an EPA registered chlorine pool product or a chlorine delivery device.
*Compared to the minimum EPA recommended chlorine level of 1.0 ppm for a stabilized swimming pool.
Part 4
FROG Leap 4 lb. Torpedo Pac
Pre-lled with chlorine tablets and ts
inside the FROG Leap Twin Chlorine
Infuzer.
Product # 01-03-7833
FROG Leap Pool Wake Up!/Pool Hibernation.
3
Notes and Safety Information
General Notes
These instructions contain information for the safe and proper
operation of these Infuzers. Observe the following principles:
• Ensure that everyone using these Infuzers follows the instructions and safety precautions.
• Keep the instructions nearby and available for reference
throughout the service life of these Infuzers.
These instructions do not provide for every possible contingency
that might be encountered in connection with installation, opera-
tion or maintenance of this equipment. Should further informa-
tion be desired or should particular issues arise which are not
covered sufciently in this manual, contact King Technology at
800-222-0169.
Explanation of the signal words
Signal words, which depict the probability and severity of harm, are used in these instructions. They are dened as follows:
Signal Word
DANGER
WARNING
Meaning
Indicates an imminently hazardous situation which, if not avoided, will result in death, serious injury
or major property damage.
Indicates a hazardous situation which, if not avoided, could result in serious injury, death, or major
property damage.
NOTICE
Indicates special instructions that are important but not related to physical injury hazards.
Explanation of the safety pictographs
The following pictographs illustrate the type of hazard.
PictographType of Danger
Safety Alert/General Hazard
Explosion Risk
Hazardous Pressure
Flammable Fire Hazard
Identication of warnings
Warnings are intended to help you recognize risks and avoid
death, injury or property damage. This is how warnings are identied:
Signal Word
Pictographs
Description of danger.
Consequences if ignored.
a The arrow signals a safety precaution to be taken to
eliminate or reduce the risk.
4
Safety Label on Infuzers
Review this label before installing or operating this system. Contact King Technology at 800-222-0169 if this label is missing from your
FROG Leap Twin Infuzers.
Fire, explosion and high pressure hazards
To minimize the risk of serious injury, death or property damage while using the FROG Leap Twin Infuzers:
a Read, understand and follow all instructions and safety precautions in the manual, and on these FROG Leap Twin Infuzers and on any label forchemicals used with this system including FROG Leap Torpedo Pacs, FROG Leap Anti-Bac Mineral Pacs and FROG Leap Pool Wake Up!/
Pool Hibernation (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT.)
DANGER
a Never use fast dissolving chlorine tablets, liquid bleach, or calcium hypochlorite in the FROG Leap Twin Infuzers.
a Never mix Trichlor chlorine tablets with Calcium Hypochlorite, or with any other form of concentrated chlorine or other chemicals.
a Never add any other types of chlorine, pH adjusters, shock treatments or algaecides through the skimmer.
These products should be added directly into the pool if required.
a Do not contaminate the FROG Leap Twin Infuzers, FROG Leap Anti-Bac Mineral Pac, FROG Leap Torpedo Pac and FROG Leap Pool Wake Up!/Pool
Hibernation (which includes FROG Leap Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT) with dirt, organic matter, pool chemicals (such as
calcium hypochlorite or pool shocks), fertilizers or other household chemicals. Contact between any of these substances and the FROG Leap Twin Infuzers
including FROG Leap Anti-Bac Mineral Pac, FROG Leap Torpedo Pac, FROG Leap Pool Wake Up!/Pool Hibernation (which includes FROG Leap Reveille,
FROG Leap Depth Charge and FROG Leap ALL-OUT) will result in a chemical reaction with the generation of heat, liberation of hazardous gasses and re
or explosion.
WARNING
a Use only FROG Leap Torpedo Pacs, FROG Leap Anti-Bac Mineral Pacs, FROG Leap Pool Wake Up!/Pool Hibernation (which includes FROG Leap
Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT) in the FROG Leap Twin Infuzers. Never use bulk chemicals.
a To prevent the build up of gas pressure in the FROG Leap Twin Infuzers, be sure the pool return line valves are open – except when opening or
servicing the unit.
a Do not inhale fumes from the FROG Leap Twin Infuzers or FROG Leap Torpedo Pac.
a Avoid sparks, smoking, or any open ame near FROG Leap Twin Infuzers or chemicals.
a Do not exceed maximum operating pressure of 50 psi or maximum temperature of 104º F.
a Do not remove the cap while under pressure. Always turn off pump and bleed off pressure before opening FROG Leap Twin Infuzers.
a Do not install automatic or fast shut off valves downstream of FROG Leap Twin Infuzers.
a Always install the FROG Leap Twin Infuzers AFTER a heater (if applicable) on the return line.
a Always install any additional sanitizing equipment AFTER and NEVER BEFORE the FROG Leap Twin Infuzers are installed on the return line.
a Do not permit children to use or climb on this product. This product must be positioned to prevent children from using it as a means of access
to the pool.
a Always stand clear of the FROG Leap Twin Infuzers during pump start-up.
a Replace FROG Leap Twin Infuzers if you see signs of cracks, damage or degradation to the Infuzers bodies or caps.
NOTICE
a Prior to pressurizing, check with your dealer to ensure your plumbing connections meet building codes.
a Failure to properly winterize your FROG Leap Twin Infuzers could result in freeze damage. (See page 19 for winterizing details.)
5
Installation Tips to Ensure Proper Performance
Before installing, read all directions carefully and contact your dealer for installation support.
WARNING
• Do not exceed maximum operating pressure of 50 psi.
• Do not install automatic or fast shut off valves
downstream of feeder.
• Always install the FROG Leap Twin Infuzers AFTER
the heater (if applicable) on the return line.
• Always install any additional sanitizing equipment
AFTER and NEVER BEFORE the FROG Leap Twin
Infuzers are installed on the return line.
1) If using a multi-speed pump, run
pump for at least 6 hours per day at
high speed (at least 40 gpm).
If the pump will run on low speed 24
hours per day or less than 6 hours per
day on high speed, you must bleed the
air while the pump is on by unscrewing
both Infuzer back knobs until water
appears from both Infuzers. Then
screw the knob back in. Repeat this
process each time the cap is removed
for any reason.
A. With High Flow Rate (greater than 80 gpm)
FROG Leap Twin
Infuzers
Install T-ttings exactly as shown.
B. With In-Floor Cleaner - TWO OPTIONS
OPTION 1- A Two-Line Installation
The best option is to have two lines. One line with pump, lter, heater and
FROG Leap Twin Infuzers and a second line with a separate pump for the
in-oor cleaning system (lter optional).
FROG Leap Twin Infuzers
✙
POOL RETURN
Line 1
PUMP
FILTER
✙
✙
✙
HEATER
2) Install system with 4-8 psi back
pressure.
Lower back pressures could result in under
chlorination. Change the eyeball ttings in
the return jets to a smaller size to increase
back pressure. Contact King Technology at
800-222-0169 for a specially designed
Infuzer pressure gauge to determine back
pressure at pool start-up.
3) Special installation Requirements:
IMPORTANT:Over chlorination or damage to the FROG
Leap Twin Infuzers or other equipment could result if
special installations A, B or C are not used in these
situations.
• If water ow is higher than 80 gallons per minute (gpm),
see diagram A.
• If an in-oor cleaner is included with pool,
see diagram B, with two options. Preferred
installation is Option 1 with two separate lines.
• If set-up is a pool and spa combination with
common equipment, see diagram C.
Line 2
FILTER
PUMP
OPTION 2 - A 3-Way Valve Installation
3-way manual valve or 3-way motor valve plus controls
FROG Leap Twin Infuzers
PUMP
FILTER
C. Pool and Spillover Spa Combination
IN-FLOOR
✙
CLEANER
VALVE
POOL WATER LEVEL
IN-FLOOR
CLEANER
VALVE
Questions? Call Customer Service at 800-222-0169
Monday thru Friday, 8 am to 5 pm central standard time.
6
FROG Leap Twin
Infuzers
Install
TOOLS NEEDED
Screwdriver
Pipe Wrench
MATERIALS NEEDED
Pipe Thread
Tap e
or Sealant
Two hose adapters
1½” x 1½” x 1¼”
Two Sections of 1½” or
1¼” Flex Hose
Base Flex-Hose Installation
Apply pipe thread tape or
1.2.
sealant to the threaded end
of both hose adapters.
Screw adapters into each end of the FROG Leap Twin
Infuzers. Hand tighten. Finish tightening by turning 1 to 2
revolutions with a pipe wrench. DO NOT OVER TIGHTEN.
The FROG Leap Twin Infuzers should always
be installed between the lter and pool
(or between heater and pool if applicable).
Never install FROG Leap Twin Infuzers
before the heater or damage to the heater
could occur.
Two
Hose
Clamps
RECOMMENDED
4-8 psi Back Pressure
To avoid over or under
chlorination, replace eyeball
ttings in the return jets to a
smaller or larger size to adjust
back pressure. For best results
use King Technology’s pressure
gauge, order part number
01-22-4000.
Attach the lter section of ex hose to one
3.
hose adapter and the return section of ex
hose to the other hose adapter with clamps
and tighten with screwdriver. Bi-ow valve
design allows water ow in either direction.
To prevent damage to
4.
heaters or lters, see your
FILTER &
PUMP
dealer about installing a
corrosion resistant check
valve which will reduce the
back ow of chlorine gas
when the FROG Leap Twin
Infuzers are turned off.
HOSE
CLAMP
CHECK
VALVE
1 1/2” X 1 1/2” X 1 1/4”
HOSE ADAPTER
1 1/2” OR 1 1/4”
FLEX HOSE
HOSE
ADAPTER
HOSE
CLAMP
HOSE
ADAPTER
HOSE CLAMP
TO POOL
For better stability, FROG Leap Twin
5.
Infuzers may be mounted on a
treated wood base using Phillips pan head screws, one in front and two
in back. If you have questions about
stability, please contact your dealer
or King Technology.
7
TOOLS NEEDED
Pipe Wrench
Hacksaw
Tape
Measure
MATERIALS NEEDED
Pipe Thread Tape or
Sealant, Primer and
PVC Cement
Hard-Plumbed Installation
The FROG Leap Twin Infuzers should always be installed
between the lter and pool (or between heater and pool if
applicable). Never install FROG Leap Twin Infuzers before
the heater or damage to the heater could occur.
Do NOT install in copper pipe if using
FROG Leap Torpedo Pac as chemical
corrosion may lead to pipe failure.
Minimum
12” above
opening
Minimum
12” above
opening
P
C
P
V
r
r
e
i
m
C
e
e
m
1½” Male Adapter
(slip x MPT)
or
2” Female
Adapter
(slip x FPT)
SECURE INFUZER
Minerals Chlorine
t
n
Do NOT install
FROG Leap Twin
Infuzers off-line.
Screw adapters into each end of FROG Leap Twin Infuzers following
1.
2.
directions for a male adapter or a female adapter. Hand tighten.
Install with water owing
through the minerals rst
and then the chlorine.
Finish tightening by turning 1 to 2 revolutions with a pipe wrench.
DO NOT OVER TIGHTEN.
If using Male adapters,
1a.1b.
apply pipe thread tape or
sealant to the threaded
end of each.
Minimum
12” to side
Allow a minimum of 12” above and on each side
of FROG Leap Twin Infuzers to ensure room for
easy replacement of FROG Leap Anti-Bac Mineral
Pac and FROG Leap Torpedo Pac.
If using Female adapters,
apply pipe thread tape or
sealant to the threaded
end of each.
Minimum
12” to side
Measure the distance
2.
between outside
male adapters and
cut out a section of
pipe 3” less than that
dimension.
For better stability,
FROG Leap Twin
Infuzers may be
P
r
i
mounted on a treated
wood base using
Phillips pan head
screws, one in front
and two in back. If
you have questions
about stability, please
contact your dealer or
King Technology.
Following Primer directions, brush Primer on
3.4.
the inside of the adapters and to ends of pipe.
Repeat this process with PVC cement following
manufacturer’s directions on that product.
To prevent damage to heaters or
5.
lters, see your dealer about installing
a corrosion resistant check valve
which will reduce the back ow of
chlorine gas when the FROG Leap
Twin Infuzers are turned off.
8
r
e
m
P
C
V
C
t
n
e
e
m
Insert PVC pipe into adapters
with a twisting action. Hold in
place 5 to 10 seconds to bond.