Introduction
The
SG-1300
technique and power. New features guarantee a much more simple amou nt of time needed to set up the
is a very powerful fog generator. It unites the current
machine.
digital
technology with proven
operation,
reducing the
2 Safety
instructions
A fog machine is not a toy!
2.1 Hazard
Occasionally directly and keep a minimum distance of 3 m to the
Never touch the nozzle when in operation.
2.2 General Safety
Never open the machine and leave the machine unattended when connected to a
Do not swallow the fog fluid. Keep it away from children. In case of eye contact, rinse with a water. Consult a doctor should you have accidentally swallowed some
Fog may activate smoke
Spilled fluid or splashed fluid droplets can cause slip hazard. Mop up the fluid and dispose of according to regulations. Froggys Fog Fluids are environmentally safe products and
recycled
Artificially-made fog can be produced in many different ways. The method used here fog, with a device which works according to the vaporizer principle, is the case has so far been reported in which a human being has been device to produce artificial fog. However, this can only be guaranteed generators are used accordingly, i.e. at the correct correctly mixed fog
hot
droplets of fluid may escape when in operation. Thus never aim at persons
biologically.
fluid.
detectors.
nozzle.
vaporization
power supply.
fluid.
most
harmless one. No
harmed
temperatures as well as with the
because of using our
if
the professional fog
can
to
produce
lot
of
it
be
We, however, or with an
inclination
recommend:
for allergies should avoid any contact with artificially-made
People with health problems or problems of the respiratory tract
fog.
3 O
perating the
SG-1300 or SG-1300-CASED
3.1 Selecting of the location
and
The location in which the
SG-1300
Free from dust y or polluted Free from
vibrations. Located on a non-flammable place or Well-ventilated with fog-free air keeping the ambient operating temperature between 5° C
45° C and the relative air humidity below
air.
is to be operated must b e
surface.
80%.
dry.
3.2 C
coupling
locked
4 Fog
The
Smoke
hanging the fluid container
Disconnect the fluid tube from the lid by retracting the brass collar and removing the
.
Remove the container from the tank housing of the Unscrew t he lid of the empty container and screw it onto the new Place the full container into the tank
housing.
SG-1300 or SG-1300-CASED
container.
Push the brass coupling into the brass collar until you hear a click. The brass collar is
firmly.
liquids
SG-1300 and SG-1300-CASED
fog
fluids.
have been designed to be used with
Froggys Fog – Training
Fire Rescue Fog High Density – Long Lasting Smoke Fluid
Use only Original Froggys Fog – Fog Fluids. Other fluids can cause considerable the unit and void the warranty. You can get more general information about fog your dealer or www.froggysfog.com / www.trainingsmoke.com Froggys Fog liquid is an environmentally safe product and it can be
directly.
recycled biologically.
5 Putting into operation
damage
fluids
now
to
from
Connect to the mains supply. Make sure the correct voltage selected (230 V/50
15.
like P
After a warm up time of approx. seven minutes the
Hz).
A “P” and two figures appear on t he display
SG-1300
is ready to start. The green
is
Ready­Led blinks if the working temperatur e is reached. As soon as the final temperature is reached, the LED
llumates permanently. Adjust the required output via the control panel and press the Enter-
button
once
to start and once to end the fogging
process.
6 Operating the
SG-1300 and SG-1300-CAS ED
The
SG-1300
is a powerful fog generator, producing every desired effect from a tiny puff of
smoke to the thickest fog. Digital technology makes fine adj ustments of the pump possible. In steps of 1% the
output can be adjusted from
1-99%.
6.1 Control panel
SG-1300
TIMER-LED, red
READY-LED, green
DMX IN-LED, yellow
MODE
UP/DOWN
ENTER
6.2 Switch of the
SG-1300
Press the Mode butten
til „OFF“ appears on the
display.
After 15 sec onds the m achine will switch of f automatica lly. On the right bottom edg e of the dis play a
red decimal point
appear.
You can also switch off the machine within these 15 seconds by pressing the
Enter-button.
When you switch off the DMX signal, the machine will be switched off automatical ly after seconds.
15
Please note that the Mode button is not menus. If menue.
you
press the mode button longer than 2 sec. the display will change into the timer
designed to scroll between the different