INSTALLATION MANUAL
Turbo Retail Combi
MODELS
TRC 8 stand alone
TRC 8 on underframe
TRC 8 stacked with TDR 8
Model TRC 8
- NOTICE -
This manual is prepared for the use of trained Service Technicians and should not be used by those not properly qualified. If you have attended a training for this product, you may be qualified to perform all the procedures in this
manual.
This manual is not intended to be all encompassing. If you have not attended a training for this product, you should read, in its entirety, the repair procedure
you wish to perform to determine if you have the necessary tools, instruments and skills required to perform the procedure. Procedures for which you do not have the necessary tools, instruments and skills should be performed by a trained technician.
Reproduction or other use of this Manual, without the express written consent of
Fri-Jado, is prohibited.
|
|
|
|
WWW.FRIJADO.COM |
Installation Manual Turbo Retail Combi form 9123845 rev. 04/2013 |
||
|
TABLE OF CONTENTS
EMPTY PAGE
Page 2 |
Installation Manual Turbo Retail Combi form 9123845 rev. 04/2013 |
|
TABLE OF CONTENTS
|
|
Versions |
Version |
Issue date |
Remarks |
|
dd/mm/yy |
|
1112 |
12/12/2011 |
First release |
1304 |
09/04/2013 |
Update of installation drawings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Installation Manual Turbo Retail Combi form 9123845 rev. 04/2013 |
Page 3 |
|
TABLE OF CONTENTS |
|
Index |
|
Index........................................................................................................................................................... |
4 |
General technical data.............................................................................................................................. |
5 |
Technical Data ....................................................................................................................................... |
5 |
Installation procedures.............................................................................................................................. |
7 |
Introduction............................................................................................................................................ |
7 |
Description of the unit........................................................................................................................... |
8 |
Unpacking and removing the unit from the pallet.............................................................................. |
9 |
Installation and positioning................................................................................................................. |
11 |
Before first use..................................................................................................................................... |
12 |
Connecting and switching on the unit............................................................................................... |
13 |
Operation and use................................................................................................................................ |
14 |
First heat up.......................................................................................................................................... |
15 |
Placing and connecting........................................................................................................................... |
16 |
TRC-8 Stand alone................................................................................................................................ |
16 |
TDR-8 on TRC-8..................................................................................................................................... |
17 |
TRC-8 on underframe........................................................................................................................... |
18 |
Page 4 |
Installation Manual Turbo Retail Combi form 9123845 rev. 04/2013 |
|
General technical data
This manual covers the TRC 8i oven. The TRC 8 intelligent is a boilerless combi steamer with 8 levels for GN pans or 40x60 racks.
All of the information, illustrations and specifications contained in this manual are based on the latest product information available at the time of printing.
STANDARD MODELS |
TRC 8 |
TRC 8 + TDR |
Power |
10,84 kW |
21,34 kW |
Voltage |
400V 3N~ 50/60Hz |
400V 3N~ 50/60Hz |
|
|
|
Max. rated current |
16A |
32A |
|
|
|
Fuses needed with power connec- |
16A |
32A |
tion400V 3N~50…60Hz ( 3 phases with |
|
|
neutral) |
|
|
|
|
|
Fuses needed with power connection |
30A |
55A |
230V 3~50…60Hz (3 Phases without |
|
|
neutral) |
|
|
|
|
|
Standard plug from factory |
16A 3P+N+E |
32A 3P+N+E |
(according to IEC 60309 and CEE-form) |
5 pole CEEFORM |
5 pole CEEFORM |
|
(according to IEC 60309) |
(according to IEC 60309) |
|
|
|
Default cable |
5x2,5 mm² 2mtr |
5x4 mm² 2mtr |
|
|
|
Gross weight |
207 kg |
410 kg |
Net weight |
176 kg |
349 kg |
|
|
|
Hight |
1235 mm |
2210 mm |
|
|
|
Width |
995 mm |
995 mm |
Depth |
780 mm |
830 mm |
|
|
|
Waterinlet connection |
G¾” |
G¾” |
|
|
|