FRIGOGLASS Plus-400, Plus-500, Super 800 SD, Super 800 HD, Super 16 User Manual

...
Plus-400 [R600] Plus-500 [R290]
ENG RUS

ENG
RUS
User Manual
Руководство пользователя
Язык оригинала данного руководства пользователя - английский. Перед началом пользования холодильной витриной, просим Вас внимательно ознакомиться с данными инструкциями.
Please see below the meaning of the symbols used throughout the manual, for your better understanding.
Для лучшего понимания, oзнaкoмьтecь со знаками, которые используются в данном документе.
WARNING ПРЕДУПРЕЖДЕНИЕ
CAUTION ВНИМАНИЕ
INFORMATION ИНФОРМАЦИЯ
FIRST AID ПЕРВАЯ ПОМОЩЬ
ENG
RUS
Table of Contents Содержание
1. Foreword ............................................... 5
2. Technical description ........................... 5
2.1 General .................................................. 5
2.2 Climate classification ........................... 5
2.3 Technical specifications ...................... 5
2.4 Physical dimensions ............................ 5
2.5 Enegry ConsumptionModel ................. 5
2.6 Maximum weight per shelf ................... 6
3. Safety Requirements ............................ 6
4. Installation & operation ........................ 7
4.1 Installation instructions ....................... 7
4.2 Adjusting the shelf (not applicable to
units with plastic inner liner) ............... 7
4.3 Connection to the mains supply ......... 8
4.4 Operation instructions ......................... 8
5. Care & cleaning..................................... 9
6. Troubleshooting ................................. 10
7. First aid ................................................ 12
8. Disposal of the unit ............................ 12
9. Recycling information ........................ 13
10. Warranty .............................................. 14
APPENDIX A: Handling & transportation
guidelines ............................................ 14
APPENDIX B: Preventive maintenance
guidelines ............................................ 14
APPENDIX C: Guidelines to prevent
corrosion of the cabinet ..................... 15
1. Предисловие ...................................... 16
2. Техническое описание...................... 16
2.1 Общая информация .......................... 16
2.2 Климатический класс ....................... 16
2.3 Технические спецификации ............ 16
2.4 Размеры .............................................. 16
2.5 Энергопотребление .......................... 17
2.6 Максимальная нагрузка на
экспозиционную полку .................... 17
3. Требования безопасности ............... 17
4. Установка и эксплуатация ............... 18
4.1 Инструкции по установке ................ 18
4.2 Установка экспозиционной полки (не
применяется в устройствах с пластмассовой внутренней
облицовкой) ....................................... 19
4.3 Подключение к главной
4.4 Инструкции по эксплуатации .......... 20
5. Уход и чистка ..................................... 21
6. Устранение неполадок ..................... 22
7. Первая помощь .................................. 24
8. Утилизация устройства .................... 24
9. Информация по утилизации ........... 24
10. Гарантийные условия ...................... 26
ПРИЛОЖЕНИЕ I: Правила обращения и
транспортирования .......................... 26
ПРИЛОЖЕНИЕ II: Правила
профилактического
обслуживания .................................... 26
ПРИЛОЖЕНИЕ III: Правила
предотвращения коррозии в
камере ................................................. 27
сети .......... 19
ENG
1. Foreword
Thank you for purchasing this new Ice Cold Merchandiser (ICM) from Frigoglass. Before using this unit please read the instructions below carefully. A well-maintained Frigoglass ICM will help you increase your sales and profits.
Manufacturer:
FRIGOGLASS EURASIA LLC,
Address:
Novosilskoe Shosse 20A, Orel 302011, RUSSIA
2. Technical description
2.1 General
The merchandiser must be connected to a grounded mains outlet with fuse rating between 10A-16A. The outlet must be easily accessible for the purposes of installation and servicing. During installation, other authorities may impose additional requirements in respect of lighting, alarm equipment and similar.
2.2 Climate classification
According to climate specifications, this ICM is rated as Class "4" (as per ISO23953-2) namely ambient temperature of 30°C and 55% humidity.
2.3 Technical specifications
Rating Voltage 220-240V, 50Hz
Thermostat +3°C ~ 7°C
Defrosting Automatic
Noise Level No more than 69 dB(a)
2.4 Physical dimensions
Model Width
(mm)
Plus-400 [R600]
Plus-500 [R290]
590 595 2016 404 110
660 723,5 2016 522 125
2.5 Enegry ConsumptionModel
Model Energy Consumption3 (KWh per day)
Plus-400 [R600] 2.1
Plus-500 [R290] 4
1
Excluding handle
2
Including rollers & feet
3
Energy consumption figure concerns specific lab testing conditions and cooler configuration. Actual energy
consumption can be different depending on market ambient conditions, product loading, optional features.
5
Depth1
(mm)
Height2
(mm)
Volume
(Lt)
Net Weight
2.6 Maximum weight per shelf
Model Maximum weight per shelf
Plus-400 [R600] ~ 32kg
Plus-500 [R290] ~ 40kg
Plus-400 [R600] and Plus-500 [R290] are equipped with HC refrigerant, and have been tested and proven to be safe according to related standards. All necessary actions for safe usage & maintenance of these appliances are described in this manual. Read carefully before using the appliance and follow all precautions included in this manual. To reduce the possibility of fire, this appliance must be installed only by a suitably qualified person.
3. Safety Requirements
All repairs and maintenance of the merchandizer should be
performed by qualified personnel only.
The ICM may only be connected to a single fixed and grounded
socket taking into account all applicable safety standards. Operation without grounding is prohibited.
Usage of extension cables and multiple sockets is strongly
prohibited.
Do not operate the merchandizer if the power cord is damaged. If
the power cord is damaged, it must be replaced with a new one. Power cord replacement must be carried out by authorized service agent.
Lamp or LED replacement must be carried out by authorized service
agent.
Do not operate the merchandiser if the front or back, grilles and
fans’ enclosures are removed or not properly attached.
Before selecting the placement location for your merchandiser you must read the information about IP protection degree in the name plate attached to the internal wall of the Cabinet. Outdoor installation is only allowed for refrigerated cabinets with IP24 degree of protection. For lower degree of protection outdoor placement of the unit is prohibited.
ENG
6
ENG
4. Installation & operation
Failure to comply with the instructions may result in high-energy consumption, poor performance of the unit and void warranty.
4.1 Installation instructions
i. After unpacking, check the cabinet for any damage caused during transportation. In the event of
damage, please contact the forwarding company.
ii. Always ensure that your merchandiser is installed on a stable surface/floor and is properly
leveled. There are 2 adjustable feet at the front, under the chassis. Please, adjust until the ICM levels and check using a spirit level, if available.
Do not place the merchandiser:
in direct sunlight or near heat sources (radiators, stoves & other
heating equipment)
outdoors, without proper protection from rain, moisture and other
atmospheric elements
Mains connection: if the mains cord supplied is not long enough, do not use an extension lead and do not replace it. Ask an authorized electrician to replace the cord with a longer one.
iii. The merchandiser must stand upright for at least 1 hour after transportation and prior to start-up.
This gives the oil time to run back to the compressor after transit and installation.
iv. Allow a minimum gap of 100mm at the top, 100mm at the rear and 50mm at the sides of the
cooler for proper ventilation. Do not place anything on top of the cooler.
in weather conditions for which it is not certified
in extreme environmental conditions (i.e. extensive exposure to
saline humidity)
on a surface with an angle more than 5o
Keep the ventilation openings, both in the appliance enclosure and in the built-in structure, clear of obstruction.
4.2 Adjusting the shelf (not applicable to units with plastic inner liner)
To adjust the shelf first unload it, lift it and unclip the shelf clips (4). Place the clips in the desired position and reposition the shelf. Make sure that the horizontal metal rods at the bottom of the shelf are between the front and back shelf clips.
7
4.3 Connection to the mains supply
Connect the ICM to a 220-240 Volts power supply on a min 10A fused & grounded socket. Do not use extension cables.
Do not connect the merchandiser to:
a non grounded wall socket or power line
improper supply voltage and frequency
power supply that does not comply with the safety regulations of
the appliance or with current legislation on electrical installations
Do not plug the cooler into a multiple outlet strip or use
extension cables.
If the supply cord is damaged, it must be replaced by the
manufacturer or authorized service provider.
Route the power cables in such a way that they are protected
from damage and they do not pose a risk of tripping.
4.4 Operation instructions
The thermostat is located inside the ICM. The thermostat is factory set to approx. +4.1 °C. If you require a higher temperature (warmer), turn the thermostat knob anticlockwise. If you require a lower temperature (colder), turn the thermostat knob clockwise.
ENG
Do not use electrical appliances inside the storage compartments of the appliance, unless recommended by the manufacturer.
8
ENG
Do not use the merchandiser to store unpacked food.
This appliance is not intended for use by young children or handicapped or infirm persons unless they are adequately supervised by a responsible person who will ensure the safe operation of the appliance on their part. Young children should be supervised to ensure that they do not play with the appliance.
Do not use mechanical devices or means other than those recommended by the manufacturer to accelerate the defrosting process.
Energy saving tips:
For energy saving and for the ICM’s better performance:
Load your ICM at night-time so that the drinks are cold once you get there in the morning.
Store your back-up stock in a cool and/or dark place so that when reloaded, the ICM will need much less time to cool them down.
Wipe moisture off the products before you place them in the ICM.
Avoid opening the door for long periods of time.
After one year, the fluorescent tubes emit 30% less light. Call a service technician to replace the fluorescent tubes or starters with new ones if you wish to have stronger lighting. Keep in mind: “Light sells”.
5. Care & cleaning
PRIOR TO ANY CLEANING (INSIDE OR OUTSIDE THE DEVICE) PROCEDURE, UNPLUG THE ICM! REMOVE THE PLUG AND MAKE SURE THAT THE OPERATOR CAN CHECK FROM ANY OF THE POINTS WHICH HE HAS ACCESS THAT THE CABLE IS UNPLUGGED.
It is important to clean the merchandiser twice a year. In order to avoid mould formation, odours, etc. product compartments must also be thoroughly cleaned. The interior of the ICM should be cleaned with a mildly soapy cloth and the glass surface using a window-cleaning agent.
Never use a water hose or high-pressure jet to clean the cooler.
9