1. Foreword .......................................4
2. Technical description ..................4
2.1 General ..........................................4
2.2 Climate classification ..................4
2.3 Technical specifications..............4
2.4 Physical dimensions....................5
2.5 Maximum weight per shelf ..........5
2.6 Noise level ....................................5
3. Installation ....................................5
3.1 Installation instructions...............5
3.2 Connection to the mains supply.7
4. Maintenance .................................7
4.1 Preventive maintenance ..............8
4.2 Cleaning ........................................8
4.3 General user information ............8
4.4 Operation ......................................8
5. Service...........................................9
6. First Aid.......................................11
7. Disposal of the unit ....................11
8. Warranty......................................11
9. Recycling information ...............11
10. Exploded diagram ......................13
ENG
1. Foreword
Thank you for purchasing this new Ice Cold Merchandiser (ICM) from Frigoglass. Before using this unit please read the instructions below carefully. A well-maintained Frigoglass ICM will help you increase your sales and profits.
This ICM has been designed for beverages.
2. Technical description
2.1 General
The merchandiser must be connected to a grounded mains outlet with a minimum fuse rating of 10A. The outlet must be easily accessible for the purposes of installation and servicing. During installation, other authorities may impose additional requirements in respect of lighting, alarm equipment and similar.
2.2 Climate classification
According to climate specifications, this ICM is tested for ‘C’ condition, namely ambient temperature of 90°F and 65% humidity. Limited outdoor use is allowed only under suitable roof / shade. Not to be placed under direct sunlight. The floor must be flat, not inclined, for stability reasons.
2.3 Technical specifications
Rating Voltage 120V 50/60Hz
Volume 135lt
Thermostat 2.0°C ~ 12.0°C
Defrosting Automatic
Capacity 140 cans (355ml)
Ambient Temp 90°F, C condition
Rated Power 217W
Current 2.23A
Refrigerant Refrigerant R134a, 0.100kg
Do not place cream spray bottles inside the cooler.
Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
ENG
2.4 Physical dimensions
Model Width Depth
1
Height
2
Weight
Impulse Chest Cooler 624mm 655mm 1,005mm 55kg
2.5 Maximum weight per shelf
Model Max Weight / Shelf No. of cans (330ml) /
Shelf
Impulse Chest Cooler ~28kg/sh 70 cans
2.6 Noise level
Model Noise level (dBA)
Impulse Chest Cooler <65.00
3. Installation
After unpacking, check the cabinet for any damage caused during transportation. In the event of damage, please contact the forwarding company.
Allow the merchandiser to stand upright for at least 1 hour prior to connection to the mains supply. This gives the oil time to run back to the compressor after transit and installation.
This appliance is not intended for use by young children or handicapped or infirm persons unless they are adequately supervised by a responsible person who will ensure the safe operation of the appliance on their part. Young children should be supervised to ensure that they do not play with the appliance.
3.1 Installation instructions
Improper leveling might result in cabin deformation affecting cooler performance.
a. Always ensure that your merchandiser is installed on level floor / counter. There
are 4 adjustable feet at the front and back under the chassis. Please adjust until the ICM levels. Check using a spirit, if available.
1
Including handle
2
Including caster wheels