PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
Replace Inverter Board
no
→ Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
VCC Resistance Check
CONTROL SETTING
Type A with Run / Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 90 to 100% 100%
Freezer Temperature
Refrigerator Temperature
Low Side Pressure
High Side Pressure
(last 1/3 cycle)
-5° to 2°F
(-20° to -17°C)
34° to 39°F
(1° to 4°C)
-2 to 6 psig
(-14 to 41 kPa)
85 to 105 psig
(586 to 724 kPa)
-1° to 3°F
(-18° to -16°C)
34° to 39°F
(1° to 4°C)
-2 to 6 psig
(-14 to 41 kPa)
120 to 135 psig
(827 to 931 kPa)
Wattage (last 1/3 cycle) 30 to 50 50 to 70
Amps (running) .4 to .8 .7 to .9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermal Cutout Heater Defrost Thermistor
Cabinet Size:
27’ & 28’ SD,
22’ CD
Freezer
Fresh Food
Ice Maker
Cut-in Cut-out Watts Ohms Cut-out
110°F
(43.3°C)
110°F
(43.3°C)
135°F
(57.2°C)
135°F
(57.2°C)
500 26.5 48°F
70 188.9 68°F
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
Termination
CONDENSER FAN MOTOR
Watts RPM Amps
3.1
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F ( 9°C), Closes at 15° F ( -9°C)
Heater Voltage 115 vac
NO
NC
NEUTRAL
ICE MAKER
RED
LINE
BLK
P-3
P-1
CE MAKER
I
GRN / YEL
MOLD
THERMAL
CUT-OUT
CAUTION
All electrical parts and wiring must be shielded from torch ame. DO NOT allow torch to touch insulation;
it will char at 200°F and ash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
BRN
MOTOR
BLK
MOUNTING
PLATE
FREEZER ICE MAKER INFORMATION
Test Cycling: Remove cover by inserting screwdriver in notch at bottom
and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice
maker should function to complete the cycle.
Water Fill Volume: The water ll adjustment screw will change the
ll time. One full turn is equal to 20cc (.68 oz.). The correct ll is 102 to
130cc (3.4 to 4.3 oz.). When a water valve is replaced, the ll volume
must be checked.
(Where Applicable)
POWER
ICE MAKER
SWITCH
RED
MOLD HEATER
165 WATTS
ICE MAKER
HOLD
C
BLK
NO
NC
RED
LT. BLUE
THERMOSTAT
NO
NC
C
WATER FILL
SWITCH
BLU
C
SHUTOFF
SWITCH
YELLOW
(8°C)
(20°C)
P-4
P-2
LT. BLUE
WATER VALVE
SERVICE DATA SHEET
A06915801
ICE & WATER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
ERROR CODES SPECIAL MODES
Display
Interpretation Mode
FZ FF FZ FF (press for up to 10 sec. simultaneously)
-- OP Open FF
Manual Defrost d F FF + and FF - Same to deactivate
Cavity Thermistor
OP -- Open FZ
Demo / Showroom 77 77 FZ + and FF - Unplug to deactivate
Cavity Thermistor
-- SH Shorted FF
Sabbath Sb Sb FZ - and FF + Same to deactivate
Cavity Thermistor
SH -- Shorted FZ
System Diagnostic No FF or FZ display,
Cavity Thermistor
SY CF UI to Main Board
Current Air Temps FZ Temp FF Temp Default Settings
communication
failure; on start up
SY CE UI to Main Board
FFIM Diagnostic Numerical display of
communication
error; after a period
in operation
SY EF Freezer Evaporator
Fan Failure
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
FRESH FOOD ICE MAKER DIAGNOSTIC MODE
Activate: Press FZ + and FF + temperature pads for up to 10 sec. simultaneously.
Deactivate: Press FF + for up to 10 sec. FFIM Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
52C Ice Maker Thermistor Activates
55C Water Valve
57C Evaporator Fan (FFIM)
58C
63C Twist Tray
Press FF + or - to move forward or backward through tests.
NOTE: Silence alarm.
Test To activate test Passing Result
FZ display shows temperature sensed by Ice Maker Thermistor.
automatically
Press Power
On-Off
Press Power
On-Off
Ice Level Sensor Activates
automatically
“OP” if open; “SH” if short
Remove ice tray to collect water into a measuring container to measure water
ll. If collecting water into ice tray, rst perform test 63C to empty ice tray.
“On” on FZ display when fan activated, “OFF” when deactivated.
Remove ice bucket.
Allow bail arm to drop freely. Pass if no alarm when tray returns to “home” position.
Hold bail arm up. Pass if alarm sounds when tray returns to “home” position.
This test runs continuously until another test is selected.
Press Power
On-Off
Remove ice bucket.
FZ display shows “1” and “GOOD”.
FRESH FOOD ICE MAKER FILL TIME ADJUSTMENT MODE
NOTE: First consider water lter condition before adjusting ll time.
Activate: Press and hold the Icemaker on/off and Powerplus Freeze pads for up to 10 seconds.
Press FF + or - to adjust between the 3 ll settings.
Deactivate: Exits automatically after 10 seconds, or press any button other than + or -.
Display
FZ FF
− Min Fill Time (default)
IC
= Mid Fill Time
= Max Fill Time
VCC COMPRESSOR MOTOR RESISTANCE CHECK
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Display Activate Deactivate
FZ + and FZ - Press and hold FF +
all UI LEDs on
to deactivate
Automatically
and C/F
after 10 sec
FZ + and FF + Press and hold FF +
rst test
to deactivate
Description
Activate: Press
Deactivate: Press
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air ow as appropriate to determine results of tests.
Test To activate test: Passing result
-- First Screen -- Blank on both UI displays, no LEDs illuminated.
-- Second Screen -- All LEDs on both UIs illuminated.
-- Third Screen -- Blank UI display, no LEDs illuminated.
28 Dispenser Paddle Press disp. paddle “On” on UI when depressed; “off” when released. “Water” is illuminated
34 Ambient Thermistor
@ UI
46 Humidity Sensor Activates automatically “OP” if open, “SH” if short. AC Heater System: Displays %RH. DC Heater
36 Ice Chute Door Depress ice chute door
47 Dispenser
Pocket Heater
66 Dispenser Light
6- Front UI Firmware Press Power On-Off Displays digit sequence; record.
2 Freezer
Defrost Heater
8 Water Valve
(Dispenser)
10 Auger Motor
11 Cube/Crush
Solenoid
12 Condenser Fan
43 Mullion Anticonden-
sation Heater
38 VCC Compressor
13 FF Lights
15 Freezer
Evaporator Fan
20 FZ Lights
22 Damper
23 FF Door Open/Close FF door “CL” on UI when door closed; “OP” when open.
24 FZ Door Open/Close FZ door “CL” on UI when door closed; “OP” when open.
26 Ice Maker
Defrost Heater
29 FF Thermistor Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of
30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of
33 Ambient Thermistor
@ Main Board
39 Freezer Evaporator
Thermistor
45 Ice Maker Mold
Thermistor
68 Ice Maker
Evaporator Thermistor
0- Firmware Parameters
1- Main Board Firmware
3- UI Firmware Press
FF + and FF +
for up to 10 sec. simultaneously. Press FF to advance through tests.
for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
on front UI.
Activates automatically UI shows temperature sensed at UI; Pass if within +20˚F/-10˚F of tem-
perature measure with gauge at UI location. “OP” if open; “SH” if short.
“Cubes” is illuminated on front UI.
System: “HI” - heater should be on. “Lo” - heater should be off. %RH is
displayed when humidity is between “Lo” and “HI” values; heater could
be on or off. “Crushed” is illuminated on front UI.
“OP” on UI when manually opened; “CL” when closed . Or using “power
or press
Power On-Off
Press Power On-Off
Press Power On-Off
Press Power On-Off
on-off”, motor drive door open “OP” or closed “CL”.
Heater on when “on’ off when “off”.
Dispenser light on when “on”, off when “off”.
Freezer defrost heater on when “on”; off when “off”. Evaporator thermis-
tor temperature is ashed. Watch for temp increase with the heater on.
It may take a few minutes for the evaporator to heat up.
Press Power On-Off
FF door must be closed. Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”.
Press Power On-Off
Press Power On-Off
FF door must be closed. Motor running when “on”; motor stopped when “off”.
FF door must be closed. Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off”.
Press Power On-Off
Press Power On-Off
Press Power On-Off
Press Power On-Off
Press Power On-Off
Fan running when “on”; stopped when “off”.
Flip mullion heater on when “on”; off when “off”.
Compressor running when “on”; off when “off”.
FF lights on when “on”; off when “off”.
Press to toggle between “off”, “LO” and “HI”. A current sensor reading is
ashed (units are not mA). OFF reading should be around 2. “LO” speed
reading should settle down to around 9. “HI” speed reading should settle
down above 40.
Press Power On-Off
Press Power On-Off
FZ lights on when “on”, off when “off”.
Perform test 15 and set fan to “HI”. Then check for air ow when open
“OP”; and no air leaks when closed “CL”.
Activates automatically Heater is turned on automatically. The ice maker evaporator thermistor
temperature is ashed. Watch for temp increase with the heater on. It
may take a few minutes for the evaporator to heat up.
temperature measured with gauge at FF thermistor location. “OP” if
open; “SH” if short.
temperature measured with gauge at FZ thermistor location.“OP” if
open; “SH” if short.
Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F
of temperature measured with gauge at main board location. “OP” if
open; “SH” if short.
Activates automatically UI shows temperature sensed by freezer evaporator thermistor; pass if
within 10°F of temperature measured with gauge at evaporator thermis-
tor location.“OP” if open; “SH” if short.
Activates automatically UI shows temperature sensed at ice maker; pass if within +20°F/-10°F
of temperature measured with gauge at ice maker mold. “OP” if open;
“SH” if short.
Activates automatically UI shows temperature sensed by evaporator thermistor; pass if within
10°F of temperature measured with gauge at evaporator thermistor loca-
tion. “OP¯” if open; “SH¯” if short.
Press Power On-Off
Press Power On-Off
Power On-Off
Displays digit sequence; record.
Displays digit sequence; record.
Displays digit sequence; record.
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied repair personnel only. Untrained persons should
not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing
this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and
properly secured.
SYSTEM DIAGNOSTIC MODE