Frigidaire RC30DG60PS Installation

Ventilation unit not shown beneath cooktop.
30"
13"
max.
cabinet
depth
18"
min.
30" min. for unprotected
cabinet bottom
24" min.
for protected
cabinet bottom
24"
1
3
/8" minimum flat distance
from cutout edge
9" min. to nearest combustible wall (each side of unit)
1
3
/8" minimum flat distance
from cutout edge
191/8"
28"
3
11/16"
26
13/16"
18
15
/16"
30"
21
13
/32"
For ventilation unit ductwork preparation and installation planning information, refer to 30" Gas Cooktop Ductwork Preparation page.
30" Gas Cooktop with Ventilation Unit
Right Side View
Rear Discharge
17
13/16"
Right Side View
Down Discharge
23
3/8"
Built-In Downdraft Cooktop
RC30DG60PS 30" Gas
Built-In Cooktop Specifications
Cooktop Shipping Weight (approx.) – 89 Lbs.
Voltage Rating – 120V / 60 Hz / 15 Amps
For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.
Amps @ 120 Volts = 15
Always consult local and national electric and gas codes.
For detailed electrical and gas supply locations, refer to 30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.
Locate cooktop between wall studs or floor joists so that ductwork may be installed properly.
Installing cooktop into pre-existing base cabinets may require modifications. Cabinets with drawers require drawers be removed and drawer fronts attached to cabinet face. and width of cabinet base because sides or back wall may need cut out and corner braces removed to accommodate unit.
Countertop opening MUST be cut based on dimensions shown, cut squarely with sides parallel to each other and with front and rear perpendicular to cabinet sides.
Pre-formed countertops with raised lip and radius at base of backsplash may not allow enough flat area for proper installation. Minimum 1-3/8" distance required from rear and front edge of cooktop cutout.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com CANADA
RC30DG60P 07/13 © 2013 Electrolux Home Products, Inc.
Verify internal length
5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
Provide adequate gas supply. Cooktop ships with 3/4" factory regulator.
LP Gas conversion kit supplied.
Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than 36".
Allow 30" minimum clearance between top of cooktop platform and bottom of unprotected wood or metal overhead cabinet.
Allow 9" minimum required clearance from left edge and right edge of cooktop to nearest combustible wall on each side.
Ductwork Preparation
For ventilation unit ductwork preparation and planning information, refer to 30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
Granite Countertop Installation Kit – (PN # 903103-9010)
Accessories information available
on the web at frigidaire.com
Specifications
subject to change.
Built-In Downdraft Cooktop
30" Gas Downdraft Cooktop – Ductwork Preparation
RC30DG60PS 30" Gas
30" Gas Downdraft Cooktop – Ductwork Preparation
Ventilation unit comes detached from cooktop. To ensure proper installation, refer to 30" Gas Downdraft Cooktop Specifications page for planning information, and installation guide on web for complete installation details including countertop and cabinet requirements.
Ducting Options
On floor, through floor or through wall.
Cabinet
side wall
Exhaust Outlet Locations –
Cut exhaust outlet hole in wall or floor based on desired installation. Exhaust duct MUST be located between wall studs or floor joists.
Cutout center
4
5/16"
6"
Electrical / Gas Supply Location
5
1/2"
C
L
3
1/4"
Recomm. gas supply stub area
4"
4"
11"
7
1/8"
Cabinet side wall
Countertop surface
Electrical Installation Note:
Locate 120 volt, 60 Hertz, properly grounded branch circuit protected by 15 amp circuit breaker or time delay fuse within shaded area shown.
Cutout center
4
5/16"
8"
6"
Bottom Exhaust Outlet
Built-In Cooktop Ductwork Preparation
Ventilation unit comes detached from cooktop. To ensure proper installation, refer to 30" Gas Downdraft Cooktop Specifications page for planning information, and installation guide on web for complete installation details including countertop and cabinet requirements.
Ducting Options – On floor, through floor or through wall.
Ventilation Unit Discharge Options – Rear or down.
Consider ductwork location and desired installation before cutting exhaust outlet hole in cabinet. For proper installation, cooktop exhaust duct MUST be located between wall studs or floor joists.
Vent exhaust air outside only and NOT into any concealed space.
Exhaust Duct Required – Galvanized or aluminum duct in 6" round or 3-1/4" x 10" rectangular, or combination of both. PVC should be used if installing under concrete slab.
Local building code must be followed in specifying approved type and schedule of ALL duct used; always use appropriate roof or wall cap with damper.
Rear Wall Exhaust Outlet
For maximum efficiency, use shortest, straightest duct run possible. Unit operates most efficiently with up to 100 equivalent feet of duct. (Refer to Calculating Duct Length Table in Product Installation Guide.)
Flexible ducting is not recommended due to severely restricted airflow; if blower outlet and floor or wall duct location do NOT align, flexible METAL ducting can be used to adapt to offset.
Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold. Cold weather installations should have additional backdraft damper installed.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-800-FRIGIDAIRE • frigidaire.com
CANADA
RC30DG60P 07/13 © 2013 Electrolux Home Products, Inc.
5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • frigidaire.ca
Accessories information available
on the web at frigidaire.com
Specifications
subject to change.