Frigidaire PLCF489GCA Installation Guide

IMPORTANT:SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
OBSERVE ALL GOVERNING CODES AND ORDINANCES.
If the information in this manual is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
FOR YOUR SAFETY:
-- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
-- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
40 1/8" Min.
01.9 cm Min.
WALL
See
2 1/2" Min.
,6.4 cm Min ,
Both sides.
if tf
note
_Min.
45.7 cm Min. (33 crr Min.)
NOTE:
. __. _},
/
24"(61cm) I /
minimum clearance between the cooktop and the bottom of thecabin_ t
Grounded
Wall Outlet
(62.2 cm Max.)
Do not pinch the power supply cord between the range and the wall.
Do not seal the range to the side cabinets.
A HEIGHT B,W!TDH C:DEPTHTOFRONT D.DEPTHWITH ' E:MINIMUM RHEIGHTOF
OFRANGE DOOROPEN.......... CUTOUTWDTH COUNTERTOP
when the bottom of wood or metal cabinet isprotected by not lessthan 1/4" (0.64 cm) flame retardant millboard covered with not lessthan No. 28 MSG sheet metal,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum, or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance when the cabinet is unprotected.
t)
/
481/8"(122.2cm) 401/8"(101.9cm) 257/8"(65.7cm) 433/4"(111.1 cm) 401/4"(102.2cm) 36" (91.4 cm) standard
35 3/8" (90 cm) min.
P/N318201762 (0803) Rev.A
Printed in United States English - pages 1-10
Espa_ol- p_iginas 11-22
Wiring Diagram - page 23-24
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing range.
2. Remove all packing material from the oven compartments before connecting the electrical supply to the range (see "Preparation", page 8).
3. Install the 4 shipping bolts from range
packaging as range leveling legs (see "Leveling the Range", page 8).
4. Two anti-tip brackets MUST be removed from lower back of range and MUST be installed (see
"Anti-tip Bracket Installation", page 10).
5. Observe all governing codes and ordinances.
6. Besure to leave these instructions with the consumer.
Important Note to the Consumer Keep these instructions with your owner's guide for future
reference.
I RTANT SAFETY
INSTRUCTIONS
Installation of this range must conform with local codes or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1-latest edition. This range has been designed certified by the American
Gas Association. As with any appliance using gas and generating heat, there are certain safety precautions you
should follow. You will find them in the Use and Care Guide, read it carefully.
To
reduce the risk of tipping
can tip.
Injury to
o All ranges
persons could result.
Install anti-tip device
Be sure your range is installed and grounded properly by a qualified installer or service
technician. This range must be electrically grounded in
accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.
70--latest edition (See grounding Instructions on page 4). The installation of appliances designed for
manufactured (mobile) home installation must conform with Manufactured Home Construction
and Safety Standard, title 24CFR, part 3280 [Formerly
the Federal Standard for Mobile Home Construction and Safety, title 24, HUD (part 280)] or when such
of the range, the range must be secured by properly installed anti-tip bracket (s) provided with
the range. To check if the bracket (s) is installed properly, remove the lower panel or storage
standard is not applicable, the Standard for
Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups), ANSI Z225.1/
NFPA 501A-latest edition, or with local codes.
Make sure the wall coverings around the range
can withstand the heat generated by the range.
Before installing the range in an area covered
with linoleum or any other synthetic floor covering, make sure the floor covering can
withstand heat at least 90°F/32°C above room temperature without shrinking, warping or
discoloring. Do not install the range over carpeting unless you place an insulating pad or sheet of 1/4" (6.4 mm) thick plywood between the range and carpeting.
Do not obstruct the flow of combustion air at the
oven vent nor around the base or beneath the lower front panel of the range. Avoid touching the
vent openings or nearby surfaces as they may become hot while the oven is in operation. This range requires
fresh air for proper burner combustion.
Never leave children alone or
unattended in the area where an appliance is in use. As children grow, teach them the proper, safe use of all
appliances. Never leave the oven door open when the range is unattended.
Stepping, leaning or sitting on the
door(s) or drawer of this range can result in serious injuries and can also cause damage to the range.
Do not store items of interest to children in the
cabinets above the range. Children could be seriously burned climbing on the range to reach items.
To eliminate the need to reach over the surface units, cabinet storage space above the units
should be avoided. Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessiveflame is hazardous. Do not use the oven as a storage space. This
creates a potentially hazardous situation.
Never use your range for warming or heating the room. Prolonged use of the range without adequate ventilation can be dangerous.
Do not store or use gasoline or other flammable vapors and liquids near this or any other
appliance. Explosions or fires could result.
In the event of an electrical power outage, the surface burners can be lit manually. To light a surface burner,
hold a lit match to the burner head and slowly turn the Surface Control knob to Lite. Use caution when lighting
surface burners manually.
Reset all controls to the "off" position after using a programmable timing operation.
Power Supply Cord Kit
The user is responsible for connecting the power supply cord to the connection block located behind the back
panel access cover. This appliance may be connected by means of
permanent "hard wiring" (flexible armored or nonmetallic shielded copper cable), or by means of a power supply cord kit. Use only a power supply cord kit rated at 125/250 volts minimum, 40 amperes minimum and marked for use with ranges. See chart (below) for cord kit connection opening size and rating information.
Cord must have either 3 or 4 conductors. For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit grounding through neutral, a 4 conductor power supply cord kit rated at 125/250 volts minimum, 40 amperes and marked for use with ranges should be used (see Figure 4).
Terminals on end of wires must either be closed loop or open-end spade lugs with upturned ends. Cord must have strain relief clamp.
Risk of fire or electrical shock exists if
an incorrect size range cord kit is used, if the Installation Instructions are not followed, or if the
strain relief bracket is discarded.
Range Connection Opening Size Chart
Refer to chart below for proper range connection opening size
and power supply cord kit ampere rating information. See serial
plate on range for kilowatt rating data.
Range Kilowatt Rating
(See Serial Plate on Range)
120/240 Volts
0-16.5 kW
16.6-22.5 kW
120/208 Volts
0-12.5 kW 40 Amp
12.6-18.5 kW 50 Amp
NOTE: Dual-fuel range is shipped from factory with
1 1/8" dia. hole as shown in figure 3. If a larger hole
is required, punch out the knockout.
Minimum
Cord kit Ampere
Rating
Diameter (inches) of Range
Connection Opening
Direct
Cord Kit Connection
1-3/8 in. 1-1/8 in. 1-3/8 in. 1-3/8 in.
3-Wire Wall
Receptacle
Electrical Connection to the Range This appliance is manufactured with the neutral terminal
connected to the range.
While connecting range, do not loosen the nuts which secure the terminal block to the range. Electrical failure or loss of electrical
connection may occur. Note: Refer to the wiring diagram at the end of this
manual.
Electrical Shock Hazard
* Electrical ground is required on this appliance. * Do not connect to the electrical supply until
appliance is permanently grounded.
* Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
* This appliance must be connected to a
grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.
* Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a fire, personal injury or electrical shock.
Three Conductor Wire Connection to Range (The 3-conductor cord or cable must be replaced with a 4-conductor cord or cable where grounding through the neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas where local codes do not permit neutral grounding)
If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord (see Figure 3):
1. Remove the 3 screws at the lower end of the rear wire cover, then bend the lower end of the rear wire
cover (access cover) upward
to expose range terminal
connection block (see
Figure 2).
3-Wire Power
SupplyCord Kit
Figure 1
_,ear wire
access cover
Pressure
regulator location
Figure 2
3
2.Removethe3 loosenuts(afteryouremovedthe rubberband)ontheterminalblockusing3/8"nut
driverorsocket.
3.Connecttheneutralwhitewireofthecopperpower supplycordtothecentersilver-coloredterminalofthe terminalblock,andconnecttheotherwirestothe outerterminals.Matchwiresandterminalsbycolor (redwiresconnectedtotherightterminal,blackwires connectedtotheleftterminal).
4.Replacethe3nutsontheterminalblock(seefigure
3).
5.Lowertheterminalcoverandreplacethe3screws.
Silver colored Terminal
Red wi re
Terminal Block
Black
wire
6. Replace the 3 nuts on the terminal block (seefig. 4).
7. Lower the terminal cover and replace the 3 screws.
Block Silver Colored
Terminal
1-1/8" Dia. Direct Connection
Hole. Punch out knockout
for 1-3/8" Dia. Cord Kit Hole
A user supplied
strain-relief must be installed To 240 V receptacle
NOTE: Be sure to remove the supplie
at this location d_t grounding strap
Figure 4
A supplied by the user
must be installed at this location
To 240 V receptacle
Figure 3
1-1/8" Dia. Direct
Connection
Hole. Punch
out knockout for 1-3/8" Dia.
Cord Kit Hole
Four Conductor Wire Connection to Range (mobile homes)
1. Remove the 3 screws at the lower end of the rear wire cover, then raise the lower end of the rear wire cover
(access cover) upward to expose range terminal connection block (seefigure 2).
2. Remove the three loose nuts (after you removed the rubber band) on the terminal block using a 3/8" nut
driver or socket.
3. Remove the grounding strap from the terminal block
and from the appliance frame.
4. Connect the ground wire (green) of the copper power
supply cord to the frame of the appliance with the ground screw, using the hole in the frame where the ground strap was removed (see Figure 4).
5. Connect the neutral of the copper power supply cord
to the center silver-colored terminal of the terminal
block, and connect the other wires to the outer
terminals. Match wires and terminals by color (red wires connected to the right terminal, black wires
connected to the left terminal).
Direct Electrical Connection to the Circuit Breaker, Fuse Box or Junction Box
If the appliance is connected directly to the circuit breaker, fuse box orjunction box, useflexible, armored or non metallic sheathed copper cable (with grounding wire). Supply a U.L. listed strain-relief at each end of the cable. At the appliance end, the cable goes through the Direct Connection Hole (seefigure 4) on the Cord Mounting Plate. Wire sizes (copper wire only) and connections must
conform to the rating of the appliance. Where local codes permit connecting the appliance
grounding conductor to the neutral (white) wire (see Figure 5). (The 3-conductor cord or cable must be replaced with a 4-conductor cord or cable where grounding through the neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas where local codes do not permit neutral grounding)
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box: a) Connect the green (or bare copper) wire, the white
appliance cable wire, and the neutral (white) wire
together.
b) Connect the 2 black wires together.
c) Connect the 2 red wires together.
4
Cablefrom
White Wire
(Neutral) _ Black
d _ Wires-
Red _ :
FWires_ ,__
Green _ U L iiN_u_ ral) (or Bare Copper) Conduit
Wire Cable from Connector
3-Wire (Grounded Neutral) Electrical System
(example: Junction Box)
Where local codes DO NOT permit connecting the appliance grounding conductor to the neutral (white) wire or if connecting to 4-wire electrical system (see Figure 6).
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white appliance cable wires.
3. In the circuit breaker, fuse box or junction box: a) Connect the white appliance cable wire to the
neutral (white) wire.
b) Connect the 2 black wires together. c) Connect the 2 red wires together. d) Connect the green (or bare copper) grounding
wire to the grounding wire of the circuit breaker, fuse box or junction box.
Green (or Bare Copper)
Residence
i
kb....._J_
Range (or CSAlisted)
Figure 5
Cable from
Residence Junction
Box
Junction Box Location
Locate junction box as shown in Figure 7. If a service cord is used, the wall receptacle should be
located in accordance with the dimensions below.
Center Line of
Range
5.4 cm) 10'
50!% ....... ALL
10"/ _/t/_ _-_/ I [
(2s.4cm) I ....... __- .... Ii i j_
T | _ _ _ _ _ _>1 =_....,CZ_'c:_
7" Max, j .L_ _ _. _r_
(1 7.8cm Max.) I _"'_. _
i_J/- \L-_ \_ Center
..... L Line of
...... Locate Electrical Hook-up Range
Range Placement
reaching over heated surface units, cabinet storage space located above the range should be avoided. If
cabinet storage space is to be provided, the risk can be reduced by installing a range hood that projects
horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinet.
Inside Shaded Area
Figure 7
To eliminate the risk of burns or fire by
i[
ii. o
Centg_ I
Range I
Wire
Red_._
[Wi,
Green (or Bare Copper)
Wire
4-Wire Electrical System
(example: Junction Box)
__._ White Wire
"'\\"_U L-listed
i;;;::::j:: . .
Cable from Conduit
Appliance Connector
(or CSAlisted)
Figure 6
1
Follow instructions for
the type of installation you have
Figure 8
If range will be installed with a cabinet on both sides, draw a center line on the floor between the
cabinets (see figure 8). If back of range will not be flush with the wall (the location of the outlet may not allow the range to be positioned against the wall), draw a line on the floor where the back edge of the range will be. Now install anti-tip brackets (see "Anti-tip Brackets Installation", page 10).
If range will be installed with a cabinet on one side only, move the range into final position. Draw a line on the floor along the side of the range that is not against
thecabinet.If backof rangewill notbeflushwith thewall(thelocationoftheoutletmaynotallowthe
rangeto bepositionedagainstthewall),drawalineon thefloorwherethebackedgeoftherangewill be.Now installanti-tipbrackets(see"Anti-tipBrackets Installation",page10).
If rangewill not beinstalledagainstacabinet, moverangeintofinalposition.Drawalineonthefloor
alongbothsidesoftherange.If backof rangewill not beflushwith thewall (thelocationoftheoutletmay
notallowtherangeto bepositionedagainstthewall), drawalineonthefloorwherethebackedgeofthe rangewillbe.Nowinstallanti-tipbrackets(see"Anti-tip BracketsInstallation",page10).
GasSupply Installation
Manual Shutoff Valve
(Connect tol/2" or 3/4"solid gas
Flare Union Ada supply pipe from the wall or floor).
The supply line should be equipped with an approved shutoff valve (see Figure 9). This valve should be located in the same room as the range and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.Open the shutoff valve in the gas supply line. Wait a few minutes for gas to move through the gas line.
The gas supply between the shutoff valve and the regulator may be connected by rigid piping or by A.G.A./ C.G.A.-approved flexible metallic union connected piping where local codes permit use. The gas supply piping can be through the side wall of the right cabinet. The right side cabinet is an ideal
location for the main shutoff valve.
Do not make the connection too tight.
The regulator is die cast. Overtightening may crack the regulator resulting in a gas leak and possible fire or explosion.
Assemble the flexible conduit from the gas supply pipe to the pressure regulator in this order:
1- manual shutoff valve, 2- flare union adapter, 3- flexible conduit, 4- flare union adapter, 5- pressure regulator.
Flexible Appliance
Conduit
(Instafl sufficient length
of flexible conduit
to aflow the range to
be pulled completely
out of the cut-out area
for proper servicing.
When shipped from the factory, this unit is designed to operate on 4" water column (1.0 kPa) Natural gas manifold pressure. A convertible pressure regulator (see figure 2) is connected to the range manifold and MUST be connected in series with the gas supply line. To access the regulator, remove the drawer.
For proper operation, the maximum inlet pressure to the regulator should be no more than 14" of water column pressure (3.5 kPa).
The inlet pressure to the regulator must be at least 1" (.25 kPa) greater than the regulator manifold pressure setting. The regulator is set for 4" water column (1.0 kPa) Natural gas manifold pressure; the inlet pressure must be at least 5" water column (1.25 kPa) Natural gas. For LP/Propane gas, the regulator must be set for
10" water column (2.5 kPa) manifold pressure; the inlet
pressure must be at least 11 " water column (2.75 kPa).
Flare
Union Adaptor-
Figure 9
The gas supply line to the shutoff valve should be
1/2" or 3/4" solid pipe. The user must know the location of the main shutoff
valve and have easy accessto it. When using flexible gas conduit on the range, allow
sufficient slack to pull the range outside the cutout for cleaning or servicing.
NOTE: Do not allow the flexible conduit to get pinched between the wall and the range. To visually check, remove the range drawer.
Use pipe-joint compound made for use with Natural and LP/Propane gas to seal all gas connections. If flexible
conduit is used, be certain that it is not kinked. Leak testing of the appliance shall be conducted
according to the manufacturer's instructions. Check for leaks. After connecting the range to the gas
supply, check the system for leaks with a manometer. If a manometer is not available, turn on the gas supply and use a liquid leak detector at all joints and connections to
check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame may result in a fire or explosion.
All openings in the wall or floor where the range is to be installed must be sealed.
Tightenallconnectionsifnecessarytopreventgas leakageinthecooktoporsupplyline.
Checkalignmentof valvesafterconnectingthe cooktoptothegassupplyto besurethemanifoldpipe hasnotbeenmoved.
Disconnectthe rangeandits individualshutoff valvefromthegassupplypipingsystemduringany
pressuretestingofthesystemattestpressuresgreater than1/2psig(3.5kPaor14"watercolumn).
LP/PropaneGasConversion ThisappliancecanbeusedwithNaturalGasorPropane Gas.Itisshippedfromthefactoryforusewithnaturalgas.
IfyouwishtoconvertyourrangeforusewithLP/Propane gas,usethesuppliedfixedorifices;theyarecontainedina specialbagalongwithinstructionsmarked"FORLID/
PROPANEGASCONVERSION",locatedonthebackof therange,closeto theapplianceregulatorvalve.
Theconversionmustbeperformedbyaqualifiedinstaller, LPsupplierorservicetechnicianinaccordancewiththe installationinstructionsfurnishedwiththisrangeandall codesandrequirementsofalllocalcodesand requirements.Failuretofollowinstructionscouldresultin seriousinjuryorpropertydamage.Thequalifiedagency performingthisworkassumesresponsibilityforthe
conversion.
Moving the Appliance for
Servicing and Cleaning
Turn off the range line fuse or circuit breakers at the
main power source, and turn off the manual gas shut-off valve. Make sure the range is cold. Remove the service drawer and open the oven door. Lift the range at the front and slide it out of the cut-out opening without creating undue strain on the flexible gas conduit.
Isolate the range from the gas supply piping system
by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.SkPa or 14" water column).
Make sure not to pinch the flexible gas conduit at the
back of the range when replacing the unit into the cut- out opening. Replace the drawer, close the door and switch on the electrical power and gas to the range.
If the pressure regulator is connected to rigid piping, the
regulator must be disconnected before moving the appliance.
Reassemble in reverse order (see figure 9).
Failure to make the appropriate conversion
can result in personal injury and property damage.
Any additions, changes or conversions
required in order for this appliance to satisfactorily meet the application needs must be made by an authorized SearsService Center, Distributor or Qualified Agency.
7