NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Capacitor Run or Induction Run 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 25 to 35% 45 to 55%
Freezer Temperature 2° to 8°F (-17° to -13°C) 0° to 5°F (-18° to -15°C)
Refrigerator Temperature 35° to 40°F (2° to 4°C) 35° to 40°F (2° to 4°C)
Low Side Pressure (cut-in)
Low Side Pressure (cut-out) 1 to 4 psig (7 to 28 kPa) 1 to 4 psig (7 to 28 kPa)
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle) 140 to 185 140 to 185
Amps (running) 1.1 to 1.6 1.1 to 1.6
Base Voltage 115 vac (127 vac max) 115 vac (127 vac max)
Cabinet Size
18’ & 21’
14’, 15’ & 17’ 25°F (-4°C 47°F (8°C) 325 41
Mechanical Timer - Defrost 30 minutes every 10 hours of compressor run time.
Electronic Timer (ADC) - Defrost up to 24 minutes every 6-72 hours of compressor run time.
Watts RPM Amps
2.3
Electrical 115 vac (127 vac max) 60 Hertz
Thermostat Opens at 48°F (9°C) Closes at 15°F ( -9°C)
Heater Voltage
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green / Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Light Blue Neutral
PERFORMANCE DATA
8 to 16 psig ( 55 to 110
kPa)
110 to 120 psig (758 to
827 kPa)
DEFROST SPECIFICATIONS
Thermostat Heater
Cut-in Cut-out Watts Ohms
25°F
(-4°C)
CONDENSER FAN MOTOR
1100 CW Opposite
ICE MAKER SPECIFICATIONS
47°F (8°C) 375 35
Shaft
165 vac
8 to 16 psig (55 to 110 kPa)
150 to 175 psig (1034 to 1207
0.15 Running
Models with Orange wire close
at 8.96°F (-12.8°C)
kPa)
SERVICE DATA SHEET
241588205
STANDARD - AUTOMATIC DEFROST
TOP MOUNT FREEZER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
NOTE
Some products come equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.
IMPORTANT
PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
ICE MAKER INFORMATION
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying
cover from housing. Use screwdriver to rotate motor gear counterclockwise until hold­ing switch circuit is completed. All components of ice maker should function to com-
plete the cycle.
Water Fill Volume: The water ll adjustment screw will change the ll time. One
full turn is equal to 20cc (.68 oz.). The correct ll is 95 to 105cc (3.2 to 3.6 oz.). When a water valve is replaced, the ll volume must be checked.
COMPRESSOR WIRING
Induction Run Compressor with RelayP.T.C. STARTER WITH RUN CAPACITOR