• Designed for Canadian installations. To convert a natural gas
furnace to LP/Propane gas for altitudes between 0 to 4,500
feet above sea level, the main gas orifice must be replaced.
For higher altitudes (between 2,000 & 4,500 feet above seal
level) the input must be de-rated by 10%. This can be done
by simply reducing the manifold pressure without changing
the gas orifices.
• Use on standard & slow opening models only
• Not for use with step regulator valves
Application Brand
For use with G6 & L1 series gas furnaces using a
Honeywell Gas Valve
Frigidaire
For G7 Series Furnaces
• Designed for Canadian installations to convert a natural gas
furnace to LP/Propane gas. Used for altitudes between 0 to
4,500 feet above sea level
• For altitudes between 0 and 1,999 feet, only the orifice needs
to be changed. For altitudes between 2,000 and 4,500 feet,
both the orifice and the regulator pressure need to be
changed.
• Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65oC or less
• Complete system fully certified to ULC S636
• White pipe with unique blue certification markings made to SCH 40 dimensions
A45-3
Furnaces
Description Case Part Number
2" Flue Gas Venting System
2" Concentric Vent Termination Kit (no vent screen) 3
2" Wall Termination Kit (no vent screen) 1
2" x 10' Pipe (Straight End) 10
2" Coupling (HubxHub) 70
o
Elbow (HubxHub) 110
2" 45
o
2" 90
Street Elbow (SPxHub) 60
o
Long Elbow (HubxHub) 55
2" 90
o
2" 90
Extra Long Elbow (HubxHub) 40
2" Sanitary Tee (HubxHubxHub) 35
3" Flue Gas Venting System
3" Concentric Vent Termination Kit (no vent screen) 3
3" Wall Termination Kit (no vent screen) 1
3" x 10' Pipe (Straight End) 10
3" Coupling (HubxHub) 60
o
3" 45
Elbow (HubxHub) 25
o
Street Elbow (SPxHub) 15
3" 90
o
3" 90
Long Elbow (HubxHub) 23
o
Extra Long Elbow (HubxHub) 15
3" 90
3" Sanitary Tee (HubxHubxHub) 17
Adapters & Other Components
3" x 2" Increaser Coupling (HubxHub) 45
3" x 2" Reducer Tee (HubxHubxHub) 10
2" x 1 1/2" Reducer Bushing (SPxHub)
Used with #196278
1 1/2" x 1/2" Reducer Busing (SPxHose Barb) 80
2" Testing Plug & Bushing Kit (SPxPlug) 10
Cement
PVC Cement, Low VOC (1 pint/473ml) 12
PVC Cement, Low VOC (1 quart/946ml) 12
Transition Cement - To ABS Only (1 pint/473ml) 12
Primer should be used when installing System636 products at temperatures
PVC/CPVC Purple Primer, Low VOC (1 pint/473ml) 12
PVC/CPVC Clear Primer, Low VOC (1 pint/473ml) 12
PVC/CPVC Purple Primer, Low VOC (1qt/946ml) 12
Primer
below 0
o
C
80
196005
081216
194000
196352
196242
196232
196122
196022
196082
196006
081219
194001
196353
196243
196233
196123
196023
196083
196364
196822
196282
196278
196143
196040
196041
196044
196042
196017
196043
Concentric Vent Kits
• These "pipe-in-pipe" kits allow for both exhaust and intake pipes to
penetrate the roof or side wall through only one hole and are
certified with mechanically fastened rain caps
• Screw/bolt assembly (included) for mechanically fastening the rain
cap can be easily removed for cleaning or maintenance
Wall Termination Kits
• For a traditional vent style, IPEX’s PVC Wall Termination Vent Kits
require only two small wall penetrations for intake and exhaust.
• Kits include a white finishing plate with a self sealing foam back
that can be screwed to the exterior wall.
Testing Plug & Bushing Kit
• Allows an inline access point for flue monitoring using fully certified
System 636 components. The kit consists of a 2" x 1/2" reducer
bushing (Spig x FPT) and a removable 1/2" MPT plug.
• May be installed in new installations or added to existing lines
when monitoring is required
• Bushing must be inserted in a 2" fitting socket
• May be used on vent lines in any diameter
• Certified for use only on IPEX System 636 flue gas vent lines.
Wall
Termination
Kit
Concentric Vent Kit
Testing Plug
& Bushing
Kit
NOTES:
1. Do Not
interchange pipe, fittings or chemicals from different BH vent manufactures. Doing so will
void System636™ product certification and warranty.
2. Contractors must check local codes for proper venting
Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces
• 904231 kit fits all G6/L1 series gas furnaces with an "A" width
cabinet. May be configured for air conditioning/heat pump airflows
from 1 1/2 to 3 tons nominal capacity.
• 904075 kit fits all G6 (RA,RC,RK&RL) series gas furnaces with "B"
& "C" width cabinets. May be field configured for air conditioning/
heat pump airflows from 2 to 5 tons nominal capacity.
• Designed to maximize system efficiencies, improve air quality and
reduce sound levels
• Air conditioning and heat pump efficiencies up to 16 SEER and 8.5
HSPF
• ECM (electronically commutated motor) variable speed DC motor
allows for 12 selected cooling airflows and 8 heating airflows to
match any applications
• Extra low speed for "fan only" operation
• Extra quiet and smooth blower on and off cycles
• Warranty: Carries the balance of original equipment warranty
Description Part Number
WARNING
Not for use with Model Numbers:
*G6RK096-12B & *GF1RK096-12B
Fits "A" Width Cabinets for G6 & L1 series
Fits "B" & "C" Width Cabinets for G6: RA,RC,RK,RL series
(not suitable for "B" cabinet 1200 CFM applications)
A45-5
Furnaces
904231
904075
904231 904075
Nominal Blower Size
Maximum Motor HP
Motor Type
Cooling CFM Range*
Heating Airflow Range*
* Airflow is held constant regardless of external static pressure within the HP and RPM
limits of the motor
Variable Speed Motor Tester - TECMate PRO™
• Designed to assist field service technicians by troubleshooting GE
ECM 2.3 motors independently of the HVAC system
TECMate Pro™ Variable Speed Motor Tester
Specifications
10" x 6" 11" x 10"
1/2 3/4
Programmable
Variable Speed
720 to 1240 720 to 1870
550 to 1215 720 to 1800
Description Part Number
Programmable
Variable Speed
904232
Twinning Kit For G7 Single Stage Gas Furnaces
• Provides the capability to combine the operation of two single stage
gas furnaces with PSC motors (not for use with 2 stage, modulating or
variable speed blower models)
• Twinning function not backwards compatible with furnaces manufactured prior to June 2009
G7 Twinning Kit For Single Stage Gas Furnaces Manufactured After
• Warranty: Limited lifetime on 14 gauge heat exchanger; 1 year parts
• LFR Models: Chamber-less unit is designed for compact installations requiring front or rear flue. The unit is approved
for chimney or balanced flue venting and is ideal for electric conversions. The large filter rack can be placed on either
side, bottom or rear
• LFR-VSM Models: With the Newmac Ultratech™ Motor Control. This system incorporates the furnace, control
board, motor & blower. The 24VAC powered board uses a standard external HVAC transformer, is air conditioning
ready and has LED indication and diagnostic output.
• NLF Model: For traditional replacement or new home construction requiring front flue
• NL2 Model: For traditional replacement or new home construction requiring rear flue
• NH3 Model: Vestibuled cabinet is approved for closet clearances
• All Pre & Post Purge Burners can be used with a Sealed Venting System (SVS). This system allows direct
venting without chimneys. Required for installation: Sealed Venting Unit, Oil Flex Vent & Air Duct.
Combination Oil/Gas & Wood Furnace With Beckett AFG Burner
• Separate combustion chamber for oil/gas
• Extra large brick lined firebox
• Pre-heated combustion air is introduced by a thermostatically con-
trolled draft system
• Disposable air filters
• Warranty: 10 year limited on the heat exchanger
• CL85/95 Model: Automatic switching from wood to oil
• CL86/96C Model: Automatic switching from wood to oil, separate
thermostats & large fire door. Burns wood without grates for better
control and efficiency.
• CL86/96G Model (Wood/Oil/Coal): Where wood or coal is avail-
able, this model gives the ultimate conservation choice. Large firebox
and firedoor with shaker grates for coal.
CFM
900/1000 82,000/94,000 1/3 HP Newmac
1200/1200 86,000/ 96,000 1/3 HP Newmac
1200/1200 86,000/ 96,000 1/3 HP Newmac
Btuh
Output
Blower
Motor
Brand
A45-8
Furnaces
Part Number
(Model Number)
8010012-2B
(CL85/95)
8010015-2B
(CL86/96C)
8010014-2B
(CL86/96G)
Wood Only Furnaces
8010024G 8010001
• WA0 Model: Is a wood add-on furnace designed for operation in
conjunction with an existing residential oil furnace system with a firing rate of .75 gph to 1.10 gph. 10 year limited warranty.
• WB100 Model: Can be used alone or in conjunction with an existing
residential system. 10 year limited warranty on the heat exchanger.