Frigidaire GLRT188WDZ0 Service Data Sheet

SERVICE DATA SHEET
241582301
ICE & WATER - AUTOMATIC DEFROST
COUNTER DEPTH SIDE BY SIDE - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat
NOTE
This product comes equipped with an Adaptive Defrost Control (ADC). To activate manual defrost, press and hold the Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key 5 times within 6 seconds. A “d” in the freezer temperature window and “F” in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, press and hold Freezer temperature UP (WARMER) key while pressing the Fresh Food temperature DOWN (COLDER) key 5 times within 6 seconds. “d” and “F” will be displayed until the defrost cycle is complete. (approx. 8 minutes)
IMPORTANT
Please return this sheet to its original location.
ICE MAKER INFORMATION
Test Cycling
Press the momemtary contact on the ON/OFF switch for approximately 15 seconds. Ice maker will continue to complete the cycle.
Water Fill Volume
Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. The water fill adjustment screw will change the fill time. One turn is equal to 20cc (.68 oz.). The correct fill is 102 to 110cc (3.25 to 3.5 oz.). When a water valve is replaced, the fill volume must be checked
T
U
R
N
Mounting Plate Screws
Mounting
Plate
Screw
Motor Gear
Timing
Gear
Water Fill Adjustment
Ice Maker ON/OFF Switch
PERFORMANCE DATA
NO LOAD AND NO DOOR OPENINGS AT 37°F & 0°F CONTROL SETTING
Type A with Run/Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 32 TO 40% 55 TO 65%
Freezer Temperature
0° TO 4°F
-18° to -16°C
-1° TO 3°F
-18° to -16°C
Refrigerator Temperature
34° TO 39°F
1° to 4°C
34° TO 39°F
1° to 4°C
Low Side Pressure (cut-in)
5 to 12 psig
34 to 83 kPa
5 to 12 psig
34 to 83 kPa
Low Side Pressure (cut-out)
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure (last 1/3 of cycle)
90 to 115 psig
621 to 793 kPa
130 to 155 psig
896 to 1069 kPa
Wattage (last 1/3 of cycle) 120 to 150 130 to 160
Amps (running) 1.0 to 1.4 1.1 to 1.5
Base Voltage 115 vac (127 vac max) 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat Heater
Cabinet Size
Cut-In Cut-Out Watts Ohms
23’
25°F
-4°C
47°F
8°C
450 30
Electronic Timer–(ADC) Defrost 24 minute s every 6 to 96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
2.8 950 CW Opposite Shaft .1 Running
ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F (9°C) Closes at 15°F (-9°C)
Heater Wattage 85
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1
Green/Yellow Ground
2
Yellow Water Valve
3
Black Line
4
Light Blue Neutral
®
Loading...