READ AND SAVE THESE INSTRUCTIONS 297088700 (Feb06)
TEMPERATURE SETTING The desired temperature inside the freezer can be set using the
UP (%) and DOWN (%) buttons on the control panel, located on the door/lid of the freezer. Press either the UP or DOWN buttons
once to display the current setting. You may now use the UP and DOWN buttons to change the temperature setting to one which suits your needs. The range of settings is -10-°F to 1O-°F(-24-oCto
-12-oC) (see figures 1 and 2). The display will return to showing the temperature of the cabinet after five (5) seconds of inactivity.
ExtremeFreeze
©®
FreezerTemp
Temp Alarm
®@
To activate the Extreme Freeze feature, push the Extreme Freeze
button. The control panel will beep once and the display will now read "FF" indicating that Extreme Freeze has begun (see figure 4).
ExtremeFreeze
©@
For your convenience, Extreme Freeze will automatically turn off
after a period of 72 hours and the freezer will return to the previous temperature setting. You may deactivate Extreme Freeze at any time by pressing the Extreme Freeze button. The display will return to showing the current temperature inside the freezer and the control panel will beep once.
FreezerTemp
Figure 4
Temp Alarm
®®
Figure 1
ExtremeFreeze
©®
You may also turn off the freezer by pressing the UP button when at temperature setting of lO-oF (-12-oC). The display will read OFF
(see figure 3). The freezer will not cool anything while it is in OFF position. The door light will continue to operate while in OFF.
WARNING: The freezer still has electrical power while in OFF. Disconnect freezer from the outlet before cleaning or moving
it.
Extreme Freeze
©®
TEMPERATURE MODE CHANGE Temperature display can be changed from -°F to -oC to -oFby
pressing the ALARM RESET and DOWN arrow simultaneously until the control panel beeps. The display will change to the other
mode.
EXTREME FREEZE Extreme Freeze enables the compressor to run continuously to
help cool large quantities of warm (room temperature) foods faster. Always cool sown hot foods to room temperature before placing them in the freezer. Use this feature just prior to adding large quantities of unfrozen foods (not to exceed three (3) pounds per cubic foot of freezer space). For example, do not
place more than 45 pounds of room temperature food into a 15 cubic foot freezer.
FreezerTemp
Figure 2
FreezerTemp
Figure 3
Temp Alarm
®@
Temp Alarm
®@
DISPLAY LOCKOUT
Press and hold the ALARM RESET key until the control panel
beeps to activate or deactivate the Display Lockout feature which
prevents the user from accidentally changing the temperature and
extreme freeze settings. "L0c'' (LOCK) will be displayed for three
(3) seconds indicating that the control panel is locked (see figure
5). Once in lockout when a key is pressed, "L0 c'' will display for three (3)seconds. When the lockout isdeactivated, "U L" (UNLOCK) will display for 1 second (see figure 6).
Extreme Freeze
©®
ExtremeFreeze
©®
FreezerTemp
Figure 5
FreezerTemp
Figure 6
Temp Alarm
®@
Temp Alarm
®@
ALARM FUNCTIONS
TEMPERATURE ALARM
Ifthe cabinet temperature rises to a level above 23-oF(-5-oC),a high
temperature alarm will be activated. The control panel will beep
every five (5) seconds, the red alarm light will glow and the display will flash. This will continue until the problem is determined, corrected and temperature once again drops to a level below 23-oF
(-5-oC).You may stop the beep by pressing the ALARM RESET
button. To also stop the display from flashing, press and hold the ALARM RESET button until the control panel beeps. Temperature Alarm will reactivate itself upon reaching a safe temperature.
DOOR/ LID AJAR ALARM
The door/lid alarm will activate if it is ajar for more than five (5) minutes. The control panel will beep every five (5) seconds, the red
alarm light will glow and the display will alternate between "d" (DOOR/LID) and the cabinet temperature (see figure 7). Press the ALARM RESET button to turn the audible alarm (beep) off. The display will keep flashing and the red light will stay on. Close the door/lid of the freezer to return it to normal operation.
Extreme Freeze FreezerTemp
Figure 7
POWER FAILURE If power to the freezer is lost, the power loss alarm will activate. The
display will be off but the control panel will beep every minute (see figure 8). To turn the audible alarm (beep) off, press the ALARM RESET button. The audible alarm will also turn off automatically when power is reconnected to the freezer. The temperature alarm will activate if the temperature of the cabinet rises to al level above
23-°F (-5-°C) during power failure. The red alarm light however, will not illuminate.
ExtremeFreeze _ Temp Alarm
FreezerTemp
Temp Alarm
®@
ALARM FUNCTION TABLE
Except during power loss, the red alarm light illuminates whenever there is an alarm status.
Cabinet
temperature is
displayed. FF is displayed.
Temperature
flashing on and
off. Control panel beeps every 5
seconds.
Alternating: "d"
and temperature. Control panel beeps every 5
seconds.
Alternating: "E"
and temperature. Control panel
beeps every 5 seconds.
Alternating: "CE"
and temperature. Control panel
beeps every 5 seconds.
Display off.
Normal Operation
Extreme Freeze Freezer
temperature too
high
Door ajar
Operational error
Operational error
Power failure
None
None Check power is
connected. Contact service
technician. Press ALARM RESET to
shut off audible alarm (beep).
Close door. Press
ALARM RESET to
stop audible alarm (beep).
Contact service
technician. Press ALARM RESET to
stop audible alarm (beep).
Contact service
technician. Press ALARM RESET to
stop audible alarm (beep).
Reconnect power connection.
Figure 8
SYSTEM ERROR ALARM The display will alternate between temperature and "CE" or "E"
and the control panel will beep every five (5) seconds (see figures 9 and 10). Press the ALARM RESET button to turn the audible alarm (beep) off. Call service repair to correct the problem.
Extreme Freeze FreezerTemp
©®
Figure 9
Extreme Freeze
FreezerTemp
Temp Alarm
®@
Temp Alarm
©®
Figure 10
Display Lock/Unlock: Press and hold ALARM RESET until the control panel beeps to lock or unlock the display.