Frigidaire GLFH17F8HWF, FKFH21F7HWA Owner’s Manual

Freezer
Electronics Control Guide
Congelador
La Gu[a del Control de la electr6nica
Cong_iateur
Le Guide de Contr61e d'electronique
1
READ AND SAVE THESE INSTRUCTIONS 297281200(October2008)
Temperature Setting .................................................... 2
Temperature Mode Change ........................................ 2
Extreme Freeze ........................................................... 2
Control Lockout ........................................................... 3
Temperature Alarm ..................................................... 3
Door Ajar Alarm .......................................................... 3
Power Failure .............................................................. 3
System Error Alarms ................................................... 3
Alarm Function Table .................................................. 4
TEMPERATURE SETTING
seconds. Continue by setting the control to the desired temperature.
The freezer will not cool anything while it is in "OF"position. The door light will continue to operate while in 'OF".
WARNING: The freezer still has electrical power while in OF.Disconnect freezer from the outlet before
cleaning or moving it.
f .......................................
extreme temp alarm control ::
freeze display reset lock
Door Ajar Power Loss hold for F/C o
'i
The desired temperature inside the freezer can be set us- ing the UP and DOWN arrow buttons on the control panel,
located on the door of the freezer. Press either the UP or DOWN arrow buttons to change the temperature setting to
one which suits your needs. The range of settings is -IO°F to IO°F ( -24°C to -12°C ) (See Figures 1 and 2).
extreme temp alarm control ::
freeze display reset lock
Door Ajar Power Loss hold for F/C o
Figure 1
freeze display reset lock
extreme temp alarm control
DoorAjar PowerLoss holdfor F/Co
Figure 3
TEMPERATURE MODE CHANGE Temperature display can be changed from °F to °C by
pressing the "Temp Display". Press the button again to change it back to the previous mode.
EXTREME FREEZE Extreme Freeze enables the compressor to run
continuously to help cool large quantities of warm (room temperature) foods faster. Always cool down hot foods to
room temperature before placing them in the freezer. Use this feature just prior to adding large quantities of unfrozen foods (not to exceed 3 pounds per cubic foot of freezer
space). For example, do not place more than 45 pounds of
room temperature food into a 15 cubic foot freezer. To activate the Extreme Freeze feature, push the Extreme
Freeze button. The control panel will beep once and the display will show "-F-". See Figure 4.
f 4\
extreme temp alarm control :,
freeze display reset lock
Door Ajar Power Loss hold for F/C o
'i
i
J
Figure 2
You may also turn off the freezer by pressing the UP arrow button until the display reads "10". With the display at "10', press the Up Arrow button two more times within two seconds. The display will read "OF".
The freezer can be turned ON by pressing the DOWN arrow button, with the display 1O, two times within two
Figure 4
For your convenience, Extreme Freeze will automatically turn off after a period of 72 hours and the freezer will
return to the previous temperature setting. You may deactivate Extreme Freeze at any time by pressing the
Extreme Freeze button. The display will return to displaying the last temperature setting.
CONTROLLOCKOUT Thisfeaturepreventssomeonefromaccidentallychanging
thetemperatureandExtremeFreezesettings.Toactivate thecontrollockout,pressandholdtheControlLockbutton
forthreeseconds."LO"(seeFigure5)willbedisplayedfor 3secondsindicatingthatthecontrolpanelislocked."LO" willbedisplayedifanybuttonispressed.TocancelControl Lockout,pressandholdtheControlLockbuttonforthree seconds.Whenthelockoutiscancelled,"UI"(seeFigure
6)willdisplayfor3seconds,andthenshowthecurrent temperaturesetting.
,,'_'_ _ extreme temp atarm controt i
freeze display reset lock
i
m
Door Ajar Power Loss hold for F/C o
Figure 5
f ...................................................................................................................................................................................................................................................................\
TEMPERATURE ALARM
If the cabinet temperature rises to a level above 23°F (-5°C), the "Hi Temp" display indicator will illuminate. If the
temperature stays above 23°F (-5°C) for more than one
hour, a high temperature alarm will also be activated. The
control panel will beep every 5 seconds. You may stop the
beep by pressing the Alarm Reset button. The Hi Temp
display indicator will continue to be displayed until the
problem is determined, corrected and temperature once again drops to a level below 23°F (-5°C). During the high temperature condition, the display will show the actual
internal temperature until the set temperature is once again reached. The display will then show only the set temperature.
DOOR AJAR ALARM The door alarm will activate if the door is open for more
than five minutes. There will be an audible beep every five
seconds and the "Door Ajar" indicator will illuminate. Press the Alarm Reset button to turn the audible alarm (beep)
off. The "Door Ajar" indicator will remain on until the door is closed. If the door remains open, audible alarm will sound again after five minutes. If the door remains open for 15
minutes, the interior light will shut off.
POWER FAILURE
freeze display reset lock
extreme temp alarm control
DoorAjar Power Loss hold for F/Co j
Figure 6
SABBATH MODE Sabbath mode provides the ability to disable all lights and
other electrical activity from occurring with the exception of the compressor, which continues to operate automatically. Sabbath mode is started or stopped by pressing the Control Lock and Temp Display buttons at the same time
and holding for three seconds. When started, "Sb" will be displayed for one second and then the display will turn off. When the Sabbath Mode is stopped, the current temperature setting will be displayed and all functions resume normal operation.
MANUAL DEFROST Manual defrost will force the freezer to enter an im-
mediate defrost cycle. The mode can be started or stopped by pressing the Extreme Freeze and Alarm Reset buttons at the same time for five seconds. When active, "dE" is displayed. After thirty minutes, the cycle will complete and the freezer will display the current temperature setting and
resume normal operation.
When power to the freezer is restored after the occur-
rence of a power failure, the "Power Loss" LED will be
illuminated.
If the internal temperature of the freezer has risen to a temperature greater than 23°F (-5°C), the "Hi Temp" display indicator will also be illuminated and there will
be an audible beep every five seconds. Press the Alarm
Reset button to turn the audible alarm (beep) off.
If this condition persists, the "Duration" indicator will also be illuminated and the display will show how many
hours (up to a period of 99) the internal temperature has
been above 23°F (-5°C). Food quality is considered to be
impaired at temperatures greater than 23°F (-5°C). It is left to the user's discretion to decide how to best manage the contents within the freezer.
SYSTEM ERROR ALARMS
If "E7", "E8", or "E9" are shown on the display every half
second and the control panel beeps every five seconds, call service repair to correct the problem. Press the Alarm
Reset button to turn the audible alarm (beep) off. Until changes are made, freezer will continue to run.
extreme temp alarm control
freeze display reset lock
V
Door Ajar Power Loss hold for F/C o j
F:igure 7
ALARMFUNCTIONTABLE
Except during power loss, the alarm indicators illuminate whenever there is an alarm status.
Display Status Function Response Cabinet Normal operation None
temperature
setting is
displayed AIternating"E' Operational error Contact service
and "7", "8" or "9" technician.
every half second Control panel
beeps every 5 seconds. "Door
Ajar" LED is lit.
Control panel beeps every 5
seconds. "Hi
Temp" LED is lit.
"Power A power failure Loss" LED is occurred.
illuminated. Display off. Power failure Reconnect power
Door Ajar
Freezer
temperature too
high.
Close door. Press Alarm Reset to mute audible
alarm (beep).
Contact service
technician. Press
Alarm Reset
to mute audible alarm (beep).
Press Alarm Reset button,
supply.
Loading...