Frigidaire Gallery GLEC30S9E, GLEC30S9ES, GLEC36S9EB - 36, PLEC36S9EC, GLEC36S9EB Installation Instructions Manual

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
the vicinity of this or any other appliance.
Cooktop Dimensions
Cooktop Cutout Dimensions
IMPORTANT INSTALLATION INFORMATION
• All electric cooktops run off a single phase, three-wire or four-wire cable, 240/208 volt, 60 hertz, AC only electrical supply with ground.
• Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
* 30" (76.2 cm) min. for unprotected cabinet
24" (61 cm) min. for protected surface
Figure 1 - 30" Model shown only
PRODUCT DIMENSIONS
MODEL A. LENGTH B. WIDTH C. DEPTH D. BOX LENGTH E. BOX WIDTH
5
/
30" Ceramic Model 30¾ (78.1) 21½ (54.6) 4
8
(11.7) 28
36" Ceramic Model 36¾ (93.3) 21½ (54.6) 3¼ (8.3) 34
5
/
8
(72.7) 19¼ (48.9)
5
/
8
(87.9) 19¼ (48.9)
CUT OUT DIMENSIONS
F. LENGTH G. WIDTH H. DEPTH BELOW
MODEL MINIMUM MAXIMUM MINIMUM MAXIMUM COOKTOP*
5
/
30" Ceramic Model 29 36" Ceramic Model 35
8
(75.2) 29¾ (75.6) 20¼ (51.4) 20½ (52.1) 6 (15.2)
5
/
8
(90.5) 36
1
/
8
(91.6) 20¼ (51.4) 20½ (52.1) 6 (15.2)
All dimensions are in inches (cm). * Allow 2" (5 cm) space below cooktop to clear the electric cable and allow for installation of the junction box on the
wall at the back of the cooktop.
P/N 318201427 (0810) Rev. B
English – pages 1-6
Español – pages 7-12
Français - pages 13-18
Printed in United States
Notes - 19-20
1
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Overhead Cabinet Should Not Exceed a Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min. Clearance Between the Top of the Cooking Platform and the Bottom of an Unprotected Wood or Metal Cabinet
24" (61 cm) Min. when Bottom of Wood or Metal Cabinet is Protected by Not Less Than 1/8" Flame Retardant Millboard Covered With Not Less Than No. 28 MGS Sheet Steel, 0.015" (0.4 mm) Stainless Steel, 0.024" (0.6 mm) Aluminum or
0.020" (0.5 mm) Copper
(45.7 cm)
(61 cm)
24"
K Min. Recommended
Distance Between Rear Edge of Cutout and Nearest Combustible Surface Above Countertop
18"
L
Min.
10"
( 25.4 cm)
12"
(30.5 cm)
J Min. From Edge of
Cooktop to Nearest Combustible Wall (Either Side of Unit).
Approximate Location
2 1/2" (6.4 cm) Min. From Edge of Cutout to Front Edge of Countertop
of Junction Box
Letters on this figure refer to chart on front page except for J, K & L.
CAUTION
To eliminate the risk
of burns or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7
MODEL JKL
30" Ceramic Glass 7½" (19.1 cm) 2" (5.1 cm) 30" (76.2 cm)
cm) beyond the bottom of the cabinets.
36" Ceramic Glass 7½" (19.1 cm) 2" (5.1 cm) 36" (91.4 cm)
Figure 2 – COUNTERTOP CUTOUT OPENING
It is not recommended to use drawer underneath cooktop. Empty space is needed for installation purpose.
2
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
WARNING
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for future reference.
IMPORTANT SAFETY INSTRUCTIONS
Be sure your cooktop is installed and grounded
properly by a qualified installer or service technician.
These cooktops must be electrically grounded in
accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No. 70—latest edition in the United States, or with CSA Standard C22.1, Canadian Electrical Code, Part 1, in Canada.
WARNING
must be shut off while line connections are being made. Failure to do so could result in serious injury or death.
The electrical power to the cooktop
2. These units can consume up to 9700W at 240 Vac, a circuit breaker of 40 Amp with wire gauge #8AWG shall be used.
NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the National Electrical Code ANSI/NFPA No. 70– latest edition, and local codes and ordinances.
An extension cord must not be used
with this appliance. Such use may result in a fire, electrical shock, or other personal injury.
3. The appliance should be connected to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable. The flexible armored cable extending from this appliance should be connected directly to the grounded junction box. The junction box should be located as shown in Figure 2 with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.
4. A suitable strain relief must be provided to attach the flexible armored cable to the junction box.
Unpacking Instructions
Provide Electrical Connection
Install the junction box under the cabinet and run 120/ 240 or 120/208 Volt, AC wire from the main circuit panel. DO NOT connect the wire to the circuit panel at this time.
Electrical Requirements
Observe all governing codes and local ordinances.
1. A 3-wire or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (time­delay fuse or circuit breaker is recommended). DO NOT fuse neutral. The fuse size must not exceed the circuit rating of the appliance specified on the nameplate.
Figure 3
1. Leave corner supports on cooktop until completion of Electrical Connection.
2. Be sure the bottle of cleaner conditioner packed in the literature bag is left where the user can find it easily. It is important that the ceramic-glass smoothtop be pretreated before use. See Cooktop
Cleaning and Maintenance section in the Use and Care Guide.
3
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Electrical Connection
Connect the flexible armored cable that extends from the surface unit to the junction box using a suitable strain relief at the point the armored cable enters the junction box. Then make the electrical connection as follows.
Electrical ground is required on this appliance.
This appliance is equipped with a
copper conductor flexible cable. If connection is made to aluminum house wiring, use only special connectors which are approved for joining cooper and aluminum wires in accordance with the National Electrical Code and local codes and ordinances. Improper connection of aluminum house wiring to copper leads can result in a short circuit or fire. Follow the connector manufacturer recommended procedure closely.
This appliance is manufactured with a frame connected green (or bare copper) ground wire.
DO NOT ground to a gas supply pipe.
DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.
If your cooktop has a 4-wire cable to be connected to a 3-wire grounded junction box (see figure 5):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box: connect appliance and power supply cable wires as shown in figure 5.
Cable from Power Supply
White Wire (Neutral)
Red
Wires
Ground Wire (Bare or Green Wire)
Cable from appliance
3-WIRE GROUNDED JUNCTION BOX
36" Models with Warmer Zone
U.L.-Listed Conduit Connector (or CSA listed)
Figure 5
Black Wires
Junction Box
White Wire (Neutral)
Where local codes permit connecting the appliance­grounding conductor to the neutral (white) wire:
If your cooktop has a 3-wire cable to be connected to a 3-wire grounded junction box (see figure 4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box: connect appliance and power supply cable wires as shown in figure 4.
Cable from Power Supply
White Wire (Neutral)
Red
Wires
Ground Wire (Bare or Green Wire)
Cable from appliance
3-WIRE GROUNDED JUNCTION BOX
U.L.-Listed Conduit Connector (or CSA listed)
Figure 4
Black Wires
Junction Box
You may not ground the cooktop
through the neutral (white) wire if cooktop is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes do not permit grounding through the neutral (white) wire. When grounding through the neutral (white) wire is prohibited, you must use a 4-wire power supply cable. See Figure 6 & 7. Failure to heed this warning may result in electrocution or other serious personal injury.
4
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
WARNING
If cooktop is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire:
If your cooktop has a 3-wire cable (see figure 6):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white appliance cable wires.
3. Cap the white wire from the power supply cable if a 3-wire appliance cable is supplied.
4. In the circuit breaker, fuse box or junction box: connect appliance and power supply cable wires as shown in figure 6.
Cable from Power Supply
White Wire
Ground Wire
Red
Wires
Black Wires
Junction Box
If your cooktop has a 4 wire cable (see figure 7):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white appliance cable wires.
3. In the circuit breaker, fuse box or junction box: connect appliance and power supply cable wires as shown in figure 7.
Cable from Power Supply
Ground Wire
White
Red Wires
Ground Wire (Bare or Green Wire)
Junction Box
Models 36" with Warmer Zone
4-WIRE GROUNDED JUNCTION BOX
U.L.-Listed Conduit Connector (or CSA listed)
Cable from appliance
Figure 7
Wires
Black Wires
Ground Wire (Bare or Green Wire)
Cable from appliance
4-WIRE GROUNDED JUNCTION BOX
Figure 6
U.L.-Listed Conduit Connector (or CSA listed)
If connecting to a 4-wire power supply
cable electrical system, the appliance frame connected ground wire MUST NOT be connected to the neutral wire of the 4-wire electrical system.
5
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Cooktop Installation
1. Visually inspect the cooktop for damage. Also make sure all cooktop screws are tight (see Figure 8).
Screws
Figure 8
2. Install the retainer brackets (See Figure 9).
The retainer brackets MUST be installed, to meet local codes or, in their absence, with the National Electrical Code ANSI/NFPA No. 70—latest edition, or with CSA Standard C22.1, Canadian Electrical Code, Part 1 (see Figure 9).
6 Nylon spacers
Position brackets on unit cutout center line
6 Nylon spacers
Position brackets on unit cutout center line
2 Retainer brackets
C
L
2 Retainer brackets
Figure 10 - 30" models
Cooktop
Nylon spacer
Retainer bracket
Countertop
Retainer Brackets Must
Be Installed At Least
1/16" (0.16 cm) BELOW
Countertop
Figure 9
3. Set the cooktop into the countertop cutout.
NOTE: Do not use caulking compound; cooktop should be removable for service when needed.
WARNING
Do not remove the nylon spacers on
the edges of the cooktop. These spacers center the cooktop in the space provided. The cooktop must be centered to prevent excess heat buildup that may result in heat damage or fire (see Figure 10 or Figure 11).
Figure 11 - 36" models
Checking Operation
Refer to the Use and Care Guide for operation.
CAUTION
Do not touch cooktop glass or elements.
They may be hot enough to burn you.
Model and Serial Number Location
The serial plate is located under the cooktop.
When ordering parts for or making inquires about your cooktop, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your cooktop.
Before You Call for Service
Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
Refer to your Use and Care Guide for service phone numbers.
6