Frigidaire Full Size Tumble Action Washers User Manual

Installation
Instructions
Full Size Tumble Action Washers
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure the washer is installed correctly and safely. Leave these instructions near the washer after installation for future reference.
NOTE: The electrical service to the washer must conform with local codes and ordinances and the latest edition of the National Electrical Code, ANSI/NFPA 70.
For your safety the information in
this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable vapors and liquid in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance.
· Do not touch any electrical switch; do not
use any phone in your building.
· Clear the room, building or area of all
occupants.
· Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppliers instructions.
· If you cannot reach your gas supplier, call
the fire department.
SUBJECT PAGE
Pre-Installation Requirements 2 Electrical Requirements 2 Grounding Requirements 2 Water Supply Requirements 2 Drain Requirements 2 Rough-In Dimensions 3 Location Of Your Washer 4 Unpacking 4 Installation 4-6 Replacement Parts 6
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Printed in U.S.A.
P/N 134594900A (0509)
PRE-INSTALLATION REQUIREMENTS
Tools Required for Installation:
1. Phillips screwdriver
2. 10 mm socket with ratchet.
3. Channel-lock adjustable pliers.
4. Carpenter’s level.
ELECTRICAL REQUIREMENTS
CIRCUIT - Individual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt, single phase, 60 Hz, Alternating Current. NOTE: The use of this washer with power created by gas powered generators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended.
OUTLET RECEPTACLE - Properly grounded 3-prong receptacle to be located so the power supply cord is accessible when the washer is in an installed position.
2
ROUGH-IN DIMENSIONS
NOTE: For pedestal or undercounter installation, reference page 5 "Installation".
A
With leveling leg lock nuts removed
A
3
LOCATION OF YOUR WASHER
DO NOT INSTALL YOUR WASHER:
1. In an area exposed to dripping water or outside weather conditions. The ambient temperature should never be below 60 ° F (15.6 ° C) for proper washer (detergent breakdown) operation.
2. In an area where it will come in contact with curtains or drapes.
3. In an area (garage or garage-type building) where gasoline of other flammables are kept or stored (including automobiles).
4. On carpet. Floor MUST be solid with a maximum slope of 1/2 in. per foot (1.27 cm per 30.5 cm). To ensure vibration or movement does not occur, reinforcement of the floor may be necessary.
IMPORTANT MINIMUM INSTALLATION CLEARANCES When installed in alcove or closet:
Sides, Rear = 0 in. (0 cm) Top = 0 in. (0 cm) When installed in closet: Front = 1 in. (2.54 cm) Closet door ventilation required: 2 louvered openings each 60 in2 (387 cm2), 3 in. (7.6 cm) from top and bottom of door.
UNPACKING
7. Cover the bolt holes with plugs located in the literature bag.
8. Using the shipping posts, prop up the front of the washer approximatley 2 inches to gain access to the service panel screws.
9. Remove the 2 screws and remove the service panel.
1. Cut the shipping carton along the dotted line along the base of the unit.
2. While in the carton carefully lay the washer on its back side.
3. Remove the styrofoam base.
4. Carefully return the washer to an upright position and remove the carton.
5. Carefully move the washer to within 4 feet (122cm) of the final location.
6. Remove the following from the back panel of the washer: 4 packaging bolts,
4 spacers,
2 metal "P" clamps,
POWER CORD
Remove: 4 packaging bolts, 4 spacers. metal "P" clamps,
10. Remove the two (2) styrofoam blocks located under the drum. Lift up on the drum, tilt the base of the foam blocks inwards toward the rear of the washer until free, then pull them out.
11. Replace the service panel and screws. NOTE: If the washer is to be transported at a later
date, the shipping support hardware must be reinstalled to prevent shipping damage.
Drain Hose Installation
The drain hose is field installed to allow hose orientation to the left or right, up or down depending on location of the house drain. The hose is shipped in the washer tub with the spring clamp on the coupler elbow and drain hose hanger installed on the end of the hose.
1. Remove the drain hose from the tub of the washer.
2. Push the hose onto the drain coupler at the upper left of the washer back panel until the hose con­tacts the STOP RIB.
4
Loading...