Water Fill Volume
The water fill adjustment
scre w will chang e the
fill time. One full turn is
equal to 20cc (.68 oz.).
The correct fill is 102 to
130cc (3.4 to 4.3 oz.).
When a water valve is
replaced, the fill volume
must be checked.
SERVICE DATA SHEET - 240389636
R134a
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE MODELS
IMPORTANT SAFETY NOTICE
The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing.
IMPORTANT
If any green grounding wires are moved during servicing, they
must be returned to their original position and properly secured.
CAUTION: All electrical parts and wiring must be
shielded from torch flame. Do not allow torch to contact
insulation; it will char at 200°F and flash ignite (burn) at
500°F. Excessive heat will distort the plastic liner.
NOTE: This product comes equipp ed with an Electroni c
Defrost Control. To initiate defrost, depress the fresh food light
switch 5 times in 6 seconds (light bulb must be working). To
terminate defrost, depress the fresh food light switch 5 times
in 6 seconds.
PERFORMANCE DATA
NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Type A with Run/Start Capacitor 65ºF (18ºC) Ambient 90ºF (32ºC) Ambient
Operating Time 32 to 40% 55 to 65%
Freezer Temperature 0º to 4ºF
-18º to -16ºC
-1º to 3ºF
-18º to -16ºC
Refrigerator Temperature 34º to 39ºF
1º to 4ºC
34º to 39ºF
1º to 4ºC
Low Side Pressure (cut-in) 5 to 12 psig
34 to 83 kPa
5 to 12 psig
34 to 83 kPa
Low Side Pressure (cut-out) -2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure
(Last 1/3 of cycle)
90 to 115 psig
621 to 793 kPa
130 to 155 psig
896 to 1069 kPa
Wattage (Last 1/3 of cycle) 120 to 150 130 to 160
Amps (Running) 1.2 to 1.5 1.2 to 1.5
Base Voltage 115 vac (127 vac max) 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat Heater
Cut-In Cut-Out Watts Ohms
23’ & 26’ 25ºF
-4ºC
47ºF
8ºC
450 30
Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time
CONDENSER FAN MOTOR
Watts RPM Amps
3.1 (Energy Star - Some models) 1100 CW Opposite Shaft .03 Running
8.0 2550 CW Opposite Shaft .07 Running
ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max) 60 Hertz
Thermostat Opens at 48ºF (9ºC) Closes at 15ºF (-9ºC)
Heater Wattage 165
ICE MAKER PLUG CONNECTIONS
Wire Number Wire Color Connect to:
1 Green/Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Lt. Blue Neutral