Frigidaire FRS12PYS1, FRS18PYS2, FRS22PYS2, FRS224YS2, FRS184YS2 Installation Manual

...
Page 1
Installation
Installation warnings:
1. Carefully read the installation manual before beginning.
2. Follow each step as shown.
3. Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
4. Pay attention to danger and safety notices
Choosing the installation site
Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably install the unit at one of these sites, please consult your local distributor beforehand:
1. Sites with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
4. Sites with high frequency equipment, such as wireless equipment, welding machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
Indoor Unit
1. The unit must be installed at a site
that does not obstruct the flow of air.
2. The site must support the weight of
the indoor unit.
3. The site must be easily accessible
for maintenance and replacement of the air filter.
4. The site must allow for the
necessary space around the indoor unit, as shown in the sideward figure.
5. There should be at least 3 feet (1
meter) between the unit and radio or television devices. It is ideal that the unit be installed at the center.
6. It must be far from fire, smoke or
flammable gases.
7. The indoor unit must be at least 8.2
ft(2.5 meters) from the ground.
8. The site must allow for the easy removal of the connector pipe and drain hose.
9. The unit must be installed at a site protected from direct sunlight.
More than 6"
More than
6"
More than
More than
8 .2'
6"
Choosing the installation site
06
Page 2
Outdoor Unit
1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated.
2. The site must support the weight of the outdoor unit and allow for vertical installation.
3. There must not be the possibility of increased noise and vibration at the site.
4. The unit must be installed at a site where the noise produced by its operation and air discharge does not disturb the neighbors or animals.
5. The site cannot have any leakage of flammable gases.
6. The site must provide enough space around the unit, as shown in the figure.
7. Children must not be able to access the installation site.
More than 1'
More than 6.6'
More than 1.65'
More than 1'
More than 1.65'
Choosing the installation site
07
Page 3
Parts list
NUMBER
1
2
3
4
5
6
7
8
PART NAME
Installation plate
Drain Joint
Self-tapping scr ew A #7 X 1"
Remote controller
Connecting pipe assembly
Liquid side
Gas side
Ø3/8"
Ø1/2"
Ø5/8"
capacity
Drainage Plug
capacity
Remote Controller holder
Self-tapping screw B #4 X 3/8"
capacity < 18000 Btu's
capacity > 24000 Btu’
Ø1/4"
(capacity < 12000 Btu's)
(capacity < 18000 Btu's)
(capacity > 24000 Btu’s)
= 18000 Btu's
'
= 21500 Btu
s
QTY.
1
1
5
s
10
1
1
3
2
1
2
Indoor unit
4
8
7
6
2
1
3
Outdoor unit
Parts list
08
Page 4
4
8
Indoor unit
More than 6"
7
More than 6"
Air filter
More than 1'
A
1
3
6
More than 6"
5
More than 1.65'
More than 1.65'
Parts list
09
6
B
More than 6.6'
2
Attention
1. This illustration is for explanation purposes only.
2. Copper tubes must be insulated independently
C
Outdoor
unit
Page 5
Indoor unit installation
Installation plates and dimensions
Indoor unit outline
6" or more from the wall
Refrigerant pipe hole (right) Ø 2.56"
Indoor unit outline
6" or more from the wall
Refrigerant pipe hole (right) Ø 2.56"
6" or more fr the ceiling
4.21"
3.39"
om
Installation plate
3.39"
6" or more from the wall
B
4.21"
Refrigerant pipe hole (right) Ø 2.56"
A
<
12000 Btu's
(A:33.31" B:10.83")
6" or more fr the ceiling
om
Installation plate
A
6" or more from the wall
B
Refrigerant pipe hole (right) Ø 2.56"
5.31''
7.91''
1.58''
1.58''
=18000 Btu's
(A:36.97" B:11.73")
Indoor unit installation
10
Page 6
6" or more fr the ceiling
Indoor unit outline
6" or more from the wall
B
Refrigerant pipe hole (right) Ø 2.56"
1.97''
3.94'' 4.88''
=21500 Btu's
Fixing the Installation Plate
1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown
in the figures above.
2. In the case of tiled, concrete or
similar walls, create 0.2"
diameter holes. Place anchorage supports for the appropriate assembly screws.
3. Fix the installation plate to the
A type screws.wall with eight
4. At all times securing to the wall studs is recommended.
om
Installation plate
A
(A:39.69" B:12.40")
Attention
Fit the Installation Plate and drill holes in the wall according to the wall structure and corresponding mounting points on the installation plate (Dimensions are in “mm” unless otherwise stated).
Installation plate
6" or more from the wall
1.97''
Refrigerant pipe hole (right) Ø 2.56"
Drilling the Hole
1. Determine the position of the
hole for the pipes using the
installation plate and drill the
pipe hole so that it is tilted slightly
downward.
2. Always use a pipe cover with an
opening when drilling.
Indoor unit installation
11
Indoor unit
Wall
Outdoor unit
0.2"-0.28"
Page 7
Connective pipe and drainage installation
Connective pipe
1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. must be kept as it may when relocating
The pipe cover
be used
the air
conditioner
to any other place.
2. For the rear-right-hand and rear-left­hand piping, install the piping as shown in the sideward figure. Bend
the connective pipe to
be laid at a height of 1.69" or less from the wall.
Fix the end of the
connective pipe.
Drainage
1. Run the drain hose sloping downward. Do not install the drain hose as illustrated sideward.
2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack.
Pipe cover (right)
Right piping
Indoor unit outline
Pipe holder
Rear right piping
Connective pipe
Do not block water flow by a rise.
Do not put the end of drain hose into water.
Pipe cover (left)
Left piping
Rear left piping
1.69"
Do not block water flow by a rise.
Fastening the Indoor Unit
1. Pass the piping through the hole in the wall.
2. Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the indoor unit from side to side to see that it is securely hooked.
Upper hook
Lower hook
Indoor unit installation
12
Page 8
3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping.
4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is hooked securely.
Cushioning material
Piping and wrapping
1. Bundle the tubing, connecting cable, and drain hose with tape
securely and evenly as shown in the sideward figure.
2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is
piped out of room, do not put
Indoor unit
Cable connection
Drain hose
Ponding box
Pipe room
Connective pipe
Wrapping belt
anything else in the box.
Attention
1. Connect the indoor unit first, then the outdoor unit.
2. Do not allow the piping to let out from the back of the indoor unit.
3. Be careful not to let the drain hose slack.
4. Both of the auxiliary piping should be heat insulation.
5. Be sure that the drain hose is located at the lowest side of the bundle. Locating
at the upper side may cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring.
7. Run the drain hose sloped downward to drain out the condensed water
smoothly.
Indoor unit installation
13
Page 9
Outdoor unit installation
1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration.
2. Direct the air vent toward an area without obstacles.
3. Install the unit at the site where it is exposed
especially in areas where it is frequently windy.
4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates.
5. If suspended installation is needed,
purchase kit No.EA140S from your local or servicer. The installation
bracket should accord with technique requirement in the installation bracket diagram. The installation wall should be solid brick, concrete or the same intensity construction, or action to reinforce, damping supporting should be taken. The connection between bracket and wall, bracket and the air conditioner should be firm, stable and reliable.
6. Be sure there is no obstacle which blocks radiating air, including schrubs or bushes.
to as little wind as possible,
Strong wind
Outdoor unit installation
14
Page 10
Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid mount with a bolt and nut 0.39" or
0.32" diameter (Purchased separately).
$
Air inlet
Air
inlet
%
Air outlet
Outdoor unit dimension ft(WxHxD)
[[
[[
[[
Aft) B( ft)
1'


Condensate drainage of outdoor unit (no for cooling only)
The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe .
Installation method:Insert the drain connection into one of the
Ø
25 holes of the chassis and then connect drainage pipe with drain nozzle. Insert drainage plugs into the other holes
(Only for 12000Btu's).
<
12000 Btu's
%WXV


'
Drain connection
15
Outdoor unit installation
Chassis
Drain connection
Chassis
Drainage Plug
Page 11
Refrigerant piping connection
Unit comes with 16.4' tubing bundle. It is not recommended to cut. If too long, loop for excess.
Note: Keep original bend so not kinking of the tube occurs.
Flaring work
Main cause for refrigerant leakage is due to defect in the flaring work.
Carry out correct flaring work using the following procedure:
1. Cut the pipes and the cable.
A) Use the piping kit accessory or
pipes purchased locally.
B) Measure the distance between the
indoor and the outdoor unit.
C) Cut the pipes a little longer than the
measured distance.
D) Cut the cable 4.9ft longer than the
pipe length.
2. Burr removal
A) Completely remove all burrs from
the cut cross section of pipe/tube.
B) Put the end of the copper
tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.
3. Put nut on.
Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.(It is not possible to put them on after flaring work)
Pipe
Correct
Point down
Cooper tube
Wrong
Oblique Roughness Burr
Pipe
Reamer
Flare nut
Refrigerant piping connection
16
Page 12
4. Flaring work.
Firmly hold copper pipe in a
die in the dimension shown in the table below.
Bar
Copper pipe
Max.
0.051
0.063
0.071
0.095
A (inch)
Min.
0.028
0.039
0.039
0.087
OUTER
DIAMETER (inch)
1/4
3/8
1/2
5/8
Connection Adjustment
1. Align the pipes to be connected.
2. Screw the flare nut with your fingers, and then tighten it with a spanner and torque wrench, as shown in the following figure.
Indoor unit tubing
Flare
nut
Pipings
Handle
Yoke
Red arrow mark
Clamp handle
Caution: Excessive twisting may break the nut, depending on the installation conditions.
OUTER TIGHTENING
DIAMETER (inch)
1/4
3/8
1/2
5/8
Refrigerant piping connection
17
ADDITIONAL TIGHTENING
TORQUETORQUE (lbf.in)
139 174
260 304
434 477
651 694
(lbf.in)
Page 13
Electrical work
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The circuit protector and main power switch with a 1.5 times capacity of Max. Current of the unit should be installed in power circuit.
4. Ensure the air conditioner is grounded well.
5. According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wire.
6. All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians.
7. An individual branch circuit used only for this air conditioner must be available. See the following table for suggested wire sizes and fuse specifications:
CAPACITY
<
9000 Btu's
9000 Btu's < capacity < 12000 Btu’s
> 12000 Btu's
Note: The supply voltage must be consistent with the rate voltage of the air conditioner.
POWER SUPPLY
115V~/ 60Hz
115V~/ 60Hz
208/230V~/ 60Hz
INPUT RATED AMP
Switch / Fuse
25A/25A
25A/25A
25A/25A
AWG WIRE
SIZE
1
2
12
12
Electrical work
18
Page 14
Connect the cable to the indoor unit
Terminal block of indoor unit
Cable
1. The inside and outside connecting cable can be connected without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation 16AWG or heavier cord.
3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoors respectively.
5. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch any electrical components. Secure the cable onto the control board with the cord clamp.
Electrical box
cover
0.39"
Electrical work
19
C
Code wire
1.57"
N(1) 2 3
To Outdoor Unit
Page 15
Connect the cable to the outdoor unit
Terminal block of outdoor unit
Cable
Remove the electrical control
board cover from the outdoor unit by loosening the screw.
2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. The connective cable to power supply shall be approved polychloroprene sheathed flexible cord, type designation
12AWG
or heavier cord.
3. Secure the cable onto the control board with the cord clamp.
4. To prevent the ingress of water, form a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units.
5. Insulate unused cords (conductors) with PVC -tape. P rocess them so they could not touch any electrical or metal parts.
&RYHU
6FUHZ
0.39"
Code wire
1.57"
N(1) 2 3 L N
To indoor unit To power supply
Electrical work
20
Page 16
Caution
After the confirmation of the above conditions, prepare the wiring as follows:
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover.
2. The screws which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3. Specification of power source.
4. Confirm that electrical capacity is sufficient.
5. See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
6. Confirm that the cable thickness is as specified in the power source specification.
7. Always install an earth leakage circuit breaker in a wet or moist area.
8. The following would be caused by voltage drop: vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal function of the overload protector.
9. The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air gap contact separation of at least 1/8 inch in each active (phase) conductors.
Air purging
Air and moisture in the refrigeration system have undesirable effects as indicated below:
1. Pressure in the system rises.
2. Operating current rises.
3. Cooling or heating(only for
models with heating function) efficiency drops.
4. Moisture in the refrigerant circuit may freeze and block capillary tubing.
Electrical work and air purging
21
5. Water may lead to corrosion of parts in the refrigeration system.
Therefore, the indoor unit and tubing between the indoor and outdoor unit must apply leakage test and be evacuated to remove any noncondensables and moisture from the system.
Page 17
Air purging with vacuum pump
2
1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage.
2. When relocating the unit to another place, perform evacuation using vacuum pump.
3. Pipe length and refrigerant amount:
Connective
pipe length
Less than 25'
25'~98.4'
Use vacuum pump.
'
Use vacuum pump.25'~65.6
Use vacuum pump.
Air
purging
R410a: 0.705ozs (Pipe length-25')
R410a: 1.058ozs (Pipe length-25')
Additional amount of
refrigerant to be charged
R410a: 1.058ozs (Pipe length-25')
<
( 12000Btu's)
(=18000Btu's)
(=21500Btu's)
Caution in handling the packed valve integrated in the outlets of outdoor unit.
1. Operation of opening packed valve: Open the valve stem until it hits against
the stopper. Do not try to open it further.
2. Operation of closing packed valve: Securely tighten the valve stem with a special tool. Then securely tighten the valve stem cap with a spanner or the like. Refer to
for valve stem cap tightening torque tightening torque table in page 17
Note: There is a charging port integrated in the low side outlet, but not in the high side outlet. The low side outlet is shown in the sketch map below.
Flare nut
A
B
Packed valve
Refrigerant
Indoor unitOutdoor unit
Gas
C
D
Half union
Valve body
Cap
Charge port
Valve stem
Stopper
Air purging
2
Page 18
When using the vacuum pump
For method of using a manifold valve, refer to its operation manual.
1. Completely tighten the flare nuts at
Indoor unit
connection point A, B, C and D. Connect valve core removal tool to the charging port, then connect
Outdoor unit
vacuum hose to valve core tool. Open the schrader valve. Note: The schrader valve is inside the charging port.
2. Connect the other charge hose of manifold valve to the vacuum pump.
3. Fully open the handle Lo of the manifold valve.
Manifold valve
-76cm/Hg
4. Operate the vacuum pump to evacuate. After starting evacuation, slightly loose the flare nut of the Lo valve on the gas pipe side and check if the air is entering (Operation noise of the vacuum pump changes
Handle Lo
Handle Hi
Charge hose
and a compound meter indicates 0 instead of minus), then tighten the flare nut. The procedure verifies if there are blocks inside the tubes.
5. Make evacuation for 15 minutes or more and check that the compound meter indicates
-7.6 x 10 μmHg (-1x10 Pa).
55
After the evacuation is completed, fully close the handle Lo of the manifold valve and stop the operation of the vacuum pump.
6. Turn the stem of the packed valve B about 45
o
counterclockwise for 6~7 seconds after the gas comes out, then tighten the flare nut
Vacuum pump
display in the pressure indicator is a little higher than the atmosphere pressure. This procedure verifies if the refrigerant goes through the tubes correctly.
7. Close the schrader valve, then remove the valve core tool.
Replace the charging port cap.
8. Fully open the packed valve
stems B and A.
9. Securely tighten the cap of the
packed valve.
again. Make sure the pressure
Charge hose
Air purging
23
Page 19
Electrical safety
4
Perform the electric safety check after completing installation:
1. Insulated resistance: The insulated resistance must be more than 2M .
2. Grounding work: After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resistance is less than 4 .
3. Electrical leakage check (performing during test running): During test operation after finishing installation, the serviceman can use the electric probe and multimeter to perform the electrical leakage check. Turn off the unit immediately if electrical leakage happens. Check and find out the solution ways till the unit operates properly.
Gas leak check
Soap water method
Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of the piping. If bubbles come out, the pipes have leakage point.
Leak detector
Use the leak detector to check for leakage.
Caution
A: Lo packed valve, B: Hi packed valve C and D are ends of indoor unit connection.
Electrical safety and gas leak check
indoor unit check point
Cover
Outdoor unit check point
2
Page 20
Test running
o
Perform test operation after completing gas leak check at the flare nut connections and electrical safety check.
1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on.
2. Use the MODE button to select COOL, HEAT(Only for models with heating function), AUTO and FAN to check if all the functions work well.
cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken. Manual operation is used only when the remote controller is disable or maintenance necessary.
F), the unit 3. When the ambient temperature is too low(lower than 63
Test running
25
Auto/OFF
Manual control button
Page 21
Preparing the device for operation
6
1. Contact a specialist to install the device.
2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms.
3. Before operating the air conditioner, ensure that the air filter is installed correctly.
4. If the unit has been out of use for a long period of time, it is recommended that the air filter be cleaned before use. During continuous use, clean the air filter every two weeks.
5. This air conditioner was designed for use under the following conditions:
MODE
Cool
Temperature Temperature Temperature
Indoor Indoor Outdoor Indoor Outdoor
61°F~86°F 41°F~115°F 61°F~86°F 61°F~86°F 41°F~115°F5°F~86°F
* 23°F~115°F, for the models with low temperature cooling system
only for models with heating function
*
Outdoor*
Heat
*
Dehumidifier
Attention
If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and cause the unit to function abnormally. Room relative humidity should be less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please set the horizontal louver to its maximum angle (vertically to the floor), and set HIGH fan mode. Optimum performance will be achieved within these operating temperature.
Preparing the device for operation