Frigidaire FRS124YW10, FRS124YC10 Owner’s Manual

FRIGIDA!
Welcome to the world of
simple handling and no worries
Thank you for choosing Frigidaire. This manual contains all of the information
required to guarantee your safety and the appropriate use of your air conditioner.
Please read all of the instructions before using the air conditioner and keep
this manual for future reference. We know you will enjoy your new air conditioner and thank you for choosing
our product.
We hope you will consider us for future purchase.
Environmental advices
The packaging material used is recyclable. We
recommend that you separate plastic, paper and cardboard and give them to recycling companies. If you need to dispose of this appliance in the future, do NOT throw it away with the rest of your domestic garbage.
Attention
Theair conditionerthatyou have bought may beslightlydifferentfrom the one illustratedin this manual. Pleasereferto the information relatedto the model
you have. Thisair conditionerisfor domesticuseonly.Itisnot reccomendedfor commercial or industrial use.
Con|en|s
01. Welcome ........................................................................................... 01
02. Environmental advices .......................................................................... 01
03. Contents ............................................................................................... 02
04. Safety precautions ....................................................................... 04
05. Installation:
5.1 Choosing the installation site....................................................... 07
5.2 Parts list ..................................................................................... 09
5.3 Indoor unit installation ...................................................... 11
5.4 Outdoor unit installation ............................................................ 15
5.5 Refrigerant piping connedion ..................................................... ] 7
5.6 Electrical work ...................................................................... 19
5.7 Air Purge ................................................................................... 22
5.8 Electrical safety ..................................................................... 25
5.9 Gas leak check ........................................................................... 25
5.10 Test running .............................................................................. 26
06. Operation:
6.1 Preparing the device for operation ............................................ 27
6.2 Product description ............................................................. 28
6.3 Remote control ......................................................................... 30
- Remote control operation
- Remote control specifications
- Remote control battery
- When should the batteries be replaced
- To replace batteries
- Remote control instructions
6.4 Remote control description ......................................................... 32
- On/Off
- Mode
--I-
- Fan
- €|
- TIMER ON
- TIMER OFF
- Clock
- Blow
- TEMP
- Turbo
- Sleep
- LIGHT
6.5 INTRODUCTION FOR SPECIALFUNCTION ................................. 33
6.6 How the air conditioner works ........................................ 34
- Automatic operation Cool/heat and fan only operation
Dry operation
Airflow direction adjustment
Sleep mode
Timer operation
Optimal operation
6.7 How to use the indoor unit...................................................... 38
Adjusting air flow direction Adjusting the vertical air flow direction (up/down) To setthe horizontal air flow direction (left/right) To automatically swing the air flow direction (up/down)
6.8 Manual operation ..................................................................... 40
07. Maintenance .................................................................................... 41
08. Operation tips...................................................................................... 43
09. Solution for problems ........................................................................... 45
10.Major appliance warranty ...................................................................... 46
Safety precautions
DANGER! Avoid Serious Injury or Death
]. Do not attempt to install the split air
conditioner by yourself.
2. This air conditioner contains no user-serviceable parts. Always cail
an authorized Eiectroiux servicer for repairs.
3. When moving the air conditioner, always cail an authorized Eiectroiux
servicer for disconnection and re-installation.
4. Do not insert or place fingers or objects into the air discharge area in
the front of the indoor unit.
5. Do not insert or place fingers or objects into the air discharge area
in the outdoor unit.
6. Do not start or stop the air conditioner by unplugging the power cord or
turning off the power at the electrical
box,
7. Do not cut or damage the power cord.
8. Ifthe power cord isdamaged it should only be replaced by an authorized Eiectroiux servicer.
9. In the event of a malfunction (sparks, burning smell, etc.) immediately stop
the operation, disconnect the power
cord, and cail an authorized Eiectrolux servicer.
]0.Do not operate the air conditioners
with wet hands
] ] .Do not puJJ on the power cord. ] 2.Do not drink any water that isdrained
from the air conditioners.
CAUTION! Avoid Injury or
damage to the unit or other property
1. Provide occasional ventilation during use. Do not direct airflow at
fireplaces or other heat related sources as this could cause flare ups or make units run excessively.
2. Do not climb on or place objects on the outdoor unit.
3. Do not hang objects off the indoor
unit.
4. Do not place containers containing
water on the indoor and/or outdoor units.
5. Turn off the air conditioner at the
power source when it wiil not be used for an extended period of time.
6. Periodically check the condition of the outdoor unit's installation base
for any damage.
7. Do not apply heavy pressure to the
radiator fins of the indoor and/or outdoor units.
8. Operate the indoor unit with air
filters in place.
9. Do not block or cover the intake
grille, discharge area and outlet ports.
]O.Ensurethat any eJectricaJ/eJectronic
equipment is one yard away from
the indoor unit and outdoor unit.
] ].Do not use or store flammable
gases near the indoor and/or outdoor units.
Topreventinjurytotheuserorotherpeopleandpropertydamage,the followinginstructionsmustbefollowed.
Incorrectoperationdueto ignoringofinstructionsmaycauseharmor
damage.Theseriousness is classified by the following indications.
1. Connect with the power properly.
Otherwise, it may cause electric shock or fire due to excess heat
generation.
2. Always ensure effective grounding. No grounding may cause electric
shock.
.
Disconnect the power if strange
sounds, smell, or smoke comes from it. It may cause fire and
electric shock.
4. Do not operate or stop the unit by
switching on or off the power. It may cause electric shock or fire due to heat generation.
5. Do not operate with wet hands or in
damp environment. It may cause electric shock.
6. Do not allow water to run into
electric parts. It may cause failure of machine, electric shock or fire.
7. Do not use the power cord near
flammable gas or combustibles,
such as gasoline, benzene, thinner, etc. It may cause an explosion or fire.
8. Do not use the power cord dose to heating appliances. It may cause
fire and electric shock.
9.Do not damage or use an unspecified power cord. It may
cause electric shock or fire.
]0.Do not place heavy object on the
power cord and ensure that the cord will not be compressed. There is danger of fire or electric shock.
I 1.Do not open the unit during
operation. It may cause electric shock or injury.
12.Do not drink water drained from air conditioner. It contains contaminants and could make
you sick.
13.Do not disassemble or modify unit. It may cause failure of appliance
and electric shock.
14.When the air filter is to be removed, do not touch the metal
parts of the unit. It may cause an injury.
15.When the unit is to be cleaned, switch off, and turn off the circuit
breaker. Do not clean unit when power is on as it may cause fire,
electric shock or injury.
16.Avoid direct exposure of occupants to air flow.
17.Turn off the main power switch when not using the unit for a long time.
18.The air conditioner may be dusted with an oil free cloth, or washed
with a cloth dampened in a solution of warm water and mild dishwashing detergent. Rinsethoroughly and wipe dry. Wring excesswater from cloth before wiping around controls.
19.Ensure that the installation bracket of
the outdoor unit will not damage
due to prolonged exposure. If bracket damages, there will be
concern of damage due to falling of unit.
/
20.Always insert the filters securely. Clean filter once every two weeks. Operation without filters may
cause failure.
21 .Always install circuit breaker and a
dedicated power circuit. No installation may cause fire and electric shock.
22.Do not place obstacles around air- inlets or inside of air-outlet. It may cause failure of appliance or
accident.
Choosing the installation site
Installation Warnings
1. Carefully read the installation manual before beginning.
2. Follow each step as shown.
3. Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
4. Pay attention to danger and safety notices
Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install
the unit at one of these sites, please consult your local distributor beforehand:
1. Siteswith machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
indoorUnit
1. Theunitmustbeinstalledatasite
that does not obstruct the flow of
air.
2. The site must support the weight of the indoor unit.
3. The site must be easily accessible for maintenance and replacement of the air filter.
4. The site must allow for the necessary space around the indoor
unit, as shown in the sideward figure.
5. There should be at least 3 feet (1 meter) between the unit and radio
or television devices. It is ideal that the unit be installed at the center.
6. It must be far from fire, smoke %.2 flammable gases.
7. The indoor unit must be at least
ft(2.5 meters) from the ground.
8. The site must allow for the easy removal of the connector pipe and
drain hose.
9. The unit must be installed at a site protected from direct sunlight.
More than 6"
More than 6"
More
than 8.2'
More than 6"
Outdoor Unit
, The outdoor unit must be
installed at a convenient site that is not exposed to strong
winds. The site should be dry and well ventilated.
2. The site must support the weight of the outdoor unit and allow
for vertical installation.
3. There must not be the possibility of increased noise and vibration at the site.
4. The unit must be installed at a site where the noise produced
by its operation and air discharge does not disturb the
neighbors or animals.
5. The site cannot have any
leakage of flammable gases.
More than 1.65' More
More
than 1' than 1'
More than 6.6'
than 1.65'
6. The site must provide enough space around the unit, as shown
in the figure.
7. Children must not be able to access the installation site.
More
Parts list
NUMBER PART NAME
1
2
installation plate Drain Joint
Self-tapping scr ewA#7 XI"
Remote controller
Connecting pipe assembly
6
7
8
Drainage Plug
Remote Controller holder
Self-tapping screw B #4 X 3/8"
Liquid side
Gas side
O3/8" (capacity <-.12000 Btu's)
O1/2" (capacity <-.18000 Btu's)
05/8" (capacity >/24000 Btu's)
capacity = 18000 Btu's
capacity = 2!500 Btu's
capacity <-.18000 Btu's
capacity >/24000 Btu's
O1/4"
QTY.
1 t
5
10
1
3
2
1 2
Indoor unit
Outdoor unit
indoor unit
More than 6"
Morethan6"
Air filter
More than 1.65'
More than 1'
D_ A More
than 1.65'
@
B C
More than 6.6' Outdoor
unit
@
Attention
1.ThisiUustrationisfore×plonotionpurposesonly.
2. Copperrobesmustbeinsulatedindependently
indoor unit installation
installation plates and dimensions
6" or more from
the ceiling
_<12000 Bfu's (A:33.31" B:10.83")
6" or more from
ceiling
I the Installation plate
Indoor unit outline _= /
A ..................................
__..' ....................................................m........................................
6,,ormore I i _ 6"ormore
from the wall[ [ II "11_1 8 _,, II 0 I1_°11_1[° 11 from the wall
Refrigerant pipe [ 1_14;1_ I_1;It _ [ Refrigerant pipe
hole (right) O 2.56" i _-_, _ ]_ [ hole (right) O 2.56"
_, ................................................... + .........'31'I--I++'
=18000 Bfu's (A:36.97" B:11.73")
+++,++::::+++;:::+;++:::+++++++++++++++++++_++++;;i++::+++++++++++:i:++++++++::i+++++
6" or more from the ceiling 1. Installation plate
Indoor unit outline | ,/ _,,,
_}"or more |I 0<'11:1
_- ....................................... _ ............................ _, or more
-'[I from the wall
fromthew2II '--'
Refrigerant pipe I ! ,4", I_1t_1 lalt_l f_ | I Refrigerant pipe
hole(right) 02.56" }t_ ._._ hole (right) 02.56"
Fixing the Installation Plate
1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown in the figures above.
2. In the case of tiled, concrete or similar walls, create 0.2" diameter holes. Place anchorage
supports for the appropriate assembly screws.
3. Fix the installation plate to the wall with eight A type screws.
4. At all times securing to the wall studs is recommended.
I 1,97"- - _,97"
k_3,94,,..H k.m4,S8,_t
=21500Bfu's (A:39.69'1 B:12.40')
Attention
Fitthe Installation Plateand drill holes in the wall according to thewall
structureand corresponding mounting
pointson the installation plate
(Dimensions are in "mm" unless ......................................................
otherwisestated).
installation plate
© @ @
Drilling the Hole
,
Determine the position of the
hole for the pipes using the installation plate and drill the
pipe hole so that it is tilted slightly downward.
2. Always use a pipe cover with an opening when drilling.
Wall
Connective pipe and drainage installation
Connective pipe
1. For the left-hand and right-hand piping, remove the pipe cover from
the side panel. The pipe cover
must be kept as it may be used
when relocating the air conditioner
to any other place.
.
For the rear-right-hand and rear-left-
hand piping, install the piping as shown in the sideward figure. Bend the connective pipe to be laid at
a height of 1.69" or less from the wall. Fix the end of the
connective pipe.
Drainage
1. Runthe drain hose sloping downward. Do not install the drain
hose as illustrated sideward.
.
When connecting extension drain
hose, insulate the connecting part
of extension drain hose with a shield pipe, do not let the drain
hose slack.
Pipe cover Pipe (right) holder
piping
Indoor unit outline
\
/
s i
i
i
Do not block
water flow
by a rise.
Do not put the end
n hose into water.
Connective pipe
Pipe cover (left)
piping
i -
,, _
Do not block water.flow
Fastening the indoor Unit
1. Pass the piping through the hole in the wall.
2. Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the
indoor unit from side to side to see
that it is securely hooked.
Upper hook \
Lower hook
3. Piping can easily be made by lifting the indoor unit with a
cushioning material between the indoor unit and the wall. Get it
out after finish piping.
4. Push the lower part of the indoor unit up on the wall, Then move
the indoor unit from side to side,
up and down to check if it is hooked securely.
Cushioning material
Piping and wrapping
1. Bundle the tubing, connecting cable, and drain hose with tape securely and evenly as shown
in the sideward figure.
2. Because the condensed water from rear of the indoor unit is
gathered in ponding box and is
piped out of room, do not put
x Indoor unit .,r
// Cable
Drain hosej ..........""_
Ponding
box
J
J Pipe room
Connective pipe
Wrapping belt
anything else in the box.
Attention
]. Connect the indoor unit first, then the outdoor unit.
2. Do not allow the piping to let out from the back of the indoor unit.
3. Be careful not to let the drain hose slack.
4. Both of the auxiliary piping should be heat insulation.
5. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side may cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring.
7. Run the drain hose sloped downward to drain out the condensed water smoothly.
Loading...
+ 33 hidden pages