Installation
Installation warnings:
1. Carefully read the installation manual before beginning.
2. Follow each step as shown.
3. Observe all local, state, and national electrical codes and by qualified,
licensed, authorized personnel only.
4. Pay attention to danger and safety notices
Choosing the installation site
recautions for Installation
P
Installation at the following sites may cause problems. If you must inevitably install
the unit at one of these sites, please consult your local distributor beforehand:
1. Sites with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
Indoor Unit
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight of
the indoor unit.
3. The site must be easily accessible
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the indoor
unit, as shown in the sideward
figure.
5. There should be at least 3 feet (1
meter) between the unit and radio
or television devices. It is ideal
that the unit be installed at the
center.
6. It must be far from fire, smoke or
flammable gases.
7. The indoor unit must be at least 7.5
feet (2.3 meters) from the ground.
8. The site must allow for the easy
removal of the connector pipe and
drain hose.
9. The unit must be installed at a site
protected from direct sunlight.
More
than 6"
More
than 5"
More
than 5"
More
than 7.5'
Choosing the installation site
07
Outdoor Unit
1. The outdoor unit must be
installed at a convenient site
that is not exposed to strong
winds. The site should be dry
and well ventilated.
2. The site must support the weight
of the outdoor unit and allow
for vertical installation.
3. There must not be the possibility
of increased noise and vibration
at the site.
4. The unit must be installed at a
site where the noise produced
by its operation and air
discharge does not disturb the
neighbors or animals.
5. The site cannot have any
leakage of flammable gases.
6. The site must provide enough
space around the unit, as shown
in the figure.
7. Children must not be able to
access the installation site.
More
than 1 feet
More
than 6.6 feet
More
than 2 feet
More
than 1 feet
More
than 2 feet
Choosing the installation site
07
Parts list
NUMBER PART NAME QTY
1
2
3
4
5
6
7
10
Installation plate
Clip anchor
Self-tapping screw A #7 X 1"
Seal
Drain Joint
Connecting cable
(capacity < 12000 Btu's)
Liquid side
Connecting
pipe
assembly
8
9
Remote controller
Self-tapping screw B #7 X 3/4"
Gas side
Ø1/4"
(capacity > 12000 Btu's)
Ø3/8"
(capacity < 9000 Btu's)
Ø3/8"
Ø1/2"
(capacity < 12000 Btu's)
(capacity > 12000 Btu’s)
Ø5/8"
Remote Controller holder
1
10
8
1
1
1
1
1
2
1
.
Indoor unit
10 10
98
54
1
3
2
89
Outdoor unit
Parts list
08
Indoor unit
More than 5"
More than 6"
1
3
2
8
9
Attention
10
Air filter
More than 1 feet
A
4
5
More than 6.6 feet
B
6
More than 5"
More than 2 feet
6
7
More
than 2 feet
C
Outdoor
unit
Parts list
09
1. This illustration is for explanation purposes only.
2. Copper tubes must be insulated independently
Indoor unit outline
6" or more from
the ceiling
Installation plate
5" or more
from the wall from the wall
Refrigerant pipe
hole (left) Ø 2.56"
1.77"
11.54"
1.77"
3.15
19.27"
36.25"
1
0.72"
3.55"
5" or more
Refrigerant pipe
1.77"
hole (right) Ø 2.56"
(B)
Capacity
Fixing the Installation Plate
1. Install the installation plate
horizontally over the structural
parts on the wall using the spaces
indicated on the plate, as shown
in the figures above.
2. In the case of tiled, concrete or
similar walls, create 0.2 inch
diameter holes. Place anchorage
supports for the appropriate
assembly screws.
3. Fix the installation plate to the
A type screws.wall with eight
4. At all times securing to the wall
studs is recommended.
<
12000 Btu's
Attention
Fit the Installation Plate and drill holes
in the wall according to the wall
structure and corresponding mounting
points on the installation plate
(Dimensions are in “mm” unless
otherwise stated).
Installation plate
Drilling the Hole
1. Determine the position of the
hole for the pipes using the
installation plate and drill the
pipe hole so that it is tilted slightly
downward.
2. Always use a pipe cover with an
opening when drilling.
Indoor unit installation
11
Indoor unit
Wall
Outdoor unit
0.2"-0.28"
Connective pipe and drainage installation
Connective pipe
1. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel.
must be kept as it may
when relocating
The pipe cover
be used
the air
conditioner
to any other place.
2. For the rear-right-hand and rear-lefthand piping, install the piping as
shown in the sideward figure. Bend
the connective pipe to
be laid at
a height of 1.69 inches or less from
the wall.
Fix the end of the
connective pipe.
Drainage
1. Run the drain hose sloping
downward. Do not install the drain
hose as illustrated sideward.
2. When connecting extension drain
hose, insulate the connecting part
of extension drain hose with a
shield pipe, do not let the drain
hose slack.
Pipe cover
(right)
Right piping
Indoor unit
outline
Pipe
holder
Rear right
piping
Connective
pipe
Do not block
water flow
by a rise.
Do not put the end
of drain hose into water.
Pipe cover
(left)
Left piping
Rear left
piping
1.69"
Do not block
water flow
by a rise.
Fastening the Indoor Unit
1. Pass the piping through the hole in
the wall.
2. Put the upper claw at the back of
the indoor unit on the upper hook of
the installation plate, move the
indoor unit from side to side to see
that it is securely hooked.
Upper hook
Lower hook
Indoor unit installation
12