Welcome to the world of
simple handling and no worries
Thank you for choosing Frigidaire. This manual contains all of the information
required to guarantee your safety and the appropriate use of your air
conditioner.
Please read all of the instructions before using the air conditioner and keep
this manual for future reference.
We know you will enjoy your new air conditioner and thank you for choosing
our product.
We hope you will consider us for future purchase.
Environmental advices
The packaging material used is recyclable. We
recommend that you separate plastic, paper and
cardboard and give them to recycling companies.
If you need to dispose of this appliance in the future,
do NOT throw it away with the rest of your domestic
garbage.
Attention
Welcome
01
The air conditioner that you have bought may be slightly different from the one
illustrated in this manual. Please refer to the information related to the model
you have.
This air conditioner is for domestic use only. It is not reccomended for
commercial or industrial use.
09. Solution for problems...........................................................................45
10.Major appliance 5 year parts only limited warranty................................ 46
36.64
03
Contents
Safety precautions
This appliance must be installed by a qualified licensed HVAC
technician in accordance with all applicable codes. All electrical
connections should be performed by a licensed electrician.
DANGER! Avoid Serious Injury
or Death
1. Do not attempt to install the split air
conditioner by yourself.
2. This air conditioner contains no
user-serviceable parts. Always call
an authorized Electrolux servicer for
repairs.
3. When moving the air conditioner,
always call an authorized Electrolux
servicer for disconnection and
re-installation.
4. Do not insert or place fingers or
objects into the air discharge area in
the front of the indoor unit.
5. Do not insert or place fingers or
objects into the air discharge area
in the outdoor unit.
6. Do not start or stop the air conditioner
by unplugging the power cord or
turning off the power at the electrical
box.
7. Do not cut or damage the power cord.
8. If the power cord is damaged it should
only be replaced by an authorized
Electrolux servicer.
9. In the event of a malfunction (sparks,
burning smell, etc.) immediately stop
the operation, disconnect the power
cord, and call an authorized Electrolux
servicer.
10.Do not operate the air conditioners
with wet hands
11.Do not pull on the power cord.
12.Do not drink any water that is drained
from the air conditioners.
CAUTION! Avoid Injury or
damage to the unit or other
property
1. Provide occasional ventilation
during use. Do not direct airflow at
fireplaces or other heat related
sources as this could cause flare ups
or make units run excessively.
2. Do not climb on or place objects on
the outdoor unit.
3. Do not hang objects off the indoor
unit.
4. Do not place containers containing
water on the indoor and/or outdoor
units.
5. Turn off the air conditioner at the
power source when it will not be
used for an extended period of time.
6. Periodically check the condition of
the outdoor unit’s installation base
for any damage.
7. Do not apply heavy pressure to the
radiator fins of the indoor and/or
outdoor units.
8. Operate the indoor unit with air
filters in place.
9. Do not block or cover the intake
grille, discharge area and outlet
ports.
10.Ensure that any electrical/electronic
equipment is one yard away from
the indoor unit and outdoor unit.
11.Do not use or store flammable
gases near the indoor and/or
outdoor units.
Safety precautions
04
To prevent injury to the user or other people and property damage, the
following instructions must be followed.
Incorrect operation due to ignoring of instructions may cause harm or
damage. The seriousness is classified by the following indications.
1. Connect with the power properly.
Otherwise, it may cause electric
shock or fire due to excess heat
generation.
2. Always ensure effective grounding.
No grounding may cause electric
shock.
3. Disconnect the power if strange
sounds, smell, or smoke comes
from it. It may cause fire and
electric shock.
4. Do not operate or stop the unit by
switching on or off the power. It
may cause electric shock or fire due
to heat generation.
5. Do not operate with wet hands or in
damp environment. It may cause
electric shock.
6. Do not allow water to run into
electric parts. It may cause failure of
machine, electric shock or fire.
7. Do not use the power cord near
flammable gas or combustibles,
such as gasoline, benzene, thinner,
etc. It may cause an explosion or fire.
8. Do not use the power cord close to
heating appliances. It may cause
fire and electric shock.
9.Do not damage or use an
unspecified power cord. It may
cause electric shock or fire.
10.Do not place heavy object on the
power cord and ensure that the
cord will not be compressed. There
is danger of fire or electric shock.
05
Safety precautions
11.Do not open the unit during
operation. It may cause electric
shock or injury.
12.Do not drink water drained
from air conditioner. It contains
contaminants and could make
you sick.
13.Do not disassemble or modify unit.
It may cause failure of appliance
and electric shock.
14.When the air filter is to be
removed, do not touch the metal
parts of the unit. It may cause an
injury.
15.When the unit is to be cleaned,
switch off, and turn off the circuit
breaker. Do not clean unit when
power is on as it may cause fire,
electric shock or injury.
16.Avoid direct exposure of occupants
to air flow.
17.Turn off the main power switch when
not using the unit for a long time.
18.The air conditioner may be dusted
with an oil free cloth, or washed
with a cloth dampened in a solution
of warm water and mild dishwashing
detergent. Rinse thoroughly and wipe
dry. Wring excess water from cloth
before wiping around controls.
19.Ensure that the installation bracket of
the outdoor unit will not damage
due to prolonged exposure. If
bracket damages, there will be
concern of damage due to falling
of unit.
20.Always insert the filters securely.
Clean filter once every two weeks.
Operation without filters may
cause failure.
21.Always install circuit breaker and a
dedicated power circuit. No
installation may cause fire and
electric shock.
22.Do not place obstacles around airinlets or inside of air-outlet. It may
cause failure of appliance or
accident.
Safety precautions
06
Choosing the installation site
Installation Warnings
1. Carefully read the installation manual before beginning.
2. Follow each step as shown.
3. Observe all local, state and national electric codes. This appliance must be
installed by a qualified licensed HVAC technician in accordance with all
applicable codes. All electrical connections should be performed by a licensed
electrician.
4. Pay attention to danger and safety notices
Precautions for Installation
Installation at the following sites may cause problems. If you must inevitably install
the unit at one of these sites, please consult your local distributor beforehand:
1. Sites with machine oil.
2. Sites with a high concentration of salinity, such as coastal areas.
3. Sites with sulfuric gas, such as hot water springs.
4. Sites with high frequency equipment, such as wireless equipment, welding
machines and medical installations.
5. Sites with flammable gases or volatile material.
6. Sites with special environmental conditions.
7. Laundry rooms.
07
Choosing the installation site
06
Indoor Unit
1. The unit must be installed at a site
that does not obstruct the flow of
air.
2. The site must support the weight of
the indoor unit.
3. The site must be easily accessible
for maintenance and replacement
of the air filter.
4. The site must allow for the
necessary space around the indoor
unit, as shown in the sideward
figure.
5. There should be at least 3 feet (1
meter) between the unit and radio
or television devices. It is ideal
that the unit be installed at the
center.
6. It must be far from fire, smoke or
flammable gases.
7.
We recommend the indoor unit to be
inside wall, always leaving a space of
at least 6" between the top of the
indoor unit and the ceiling.
8. The site must allow for the easy
removal of the connector pipe and
drain hose.
9. The unit must be installed at a site
protected from direct sunlight.
More
than 6"
More
than 6"
More
than 6"
installed as high up as possible on the
Outdoor Unit
1. The outdoor unit must be
installed at a convenient site
that is not exposed to strong
winds. The site should be dry
and well ventilated.
2. The site must support the weight
of the outdoor unit and allow
for vertical installation.
3. There must not be the possibility
of increased noise and vibration
at the site.
4. The unit must be installed at a
site where the noise produced
by its operation and air
discharge does not disturb the
neighbors or animals.
5. The site cannot have any
leakage of flammable gases.
More
than 1'
More
than 1.65'
More
than 1'
06
More
than 6.6'
6. The site must provide enough
space around the unit, as shown
in the figure.
7. Children must not be able to
access the installation site.
More
than 1.65'
Choosing the installation site
08
Indoor unit
More than 6"
1
More than 6"
3
6
More than 6"
4
8
7
Air filter
More than 1'
6
A
B
More than 6.6'
5
More than 1.65'
More
than 1.65'
C
Outdoor
unit
2
Attention
1. This illustration is for explanation purposes only.
2. Copper tubes must be insulated independently
Parts list
10
Indoor unit installation
Installation plates and dimensions
Indoor unit outline
6" or more
from the wall
Refrigerant pipe
hole (right) Ø 2.56"
6" or more fr
the ceiling
4.21"
3.39"
om
Installation plate
3.39"
6" or more
from the wall
B
4.21"
Refrigerant pipe
hole (right) Ø 2.56"
A
<
12000 Btu's
(A:33.31" B:10.83")
Indoor unit outline
6" or more
from the wall
Refrigerant pipe
hole (right) Ø 2.56"
6" or more fr
the ceiling
om
Installation plate
A
6" or more
from the wall
B
Refrigerant pipe
hole (right) Ø 2.56"
7.91''
=18000 Btu's
1.58''
1.58''
5.31''
(A:36.97" B:11.73")
11
Indoor unit installation
Indoor unit outline
6" or more
from the wall
6" or more fr
the ceiling
om
Installation plate
A
6" or more
from the wall
B
1.97''
Refrigerant pipe
hole (right) Ø 2.56"
3.94''4.88''
=21500 Btu's
Fixing the Installation Plate
1. Install the installation plate
horizontally over the structural
parts on the wall using the spaces
indicated on the plate, as shown
in the figures above.
2. In the case of tiled, concrete or
similar walls, create 0.2"
diameter holes. Place anchorage
supports for the appropriate
assembly screws.
3. Fix the installation plate to the
A type screws.wall with eight
1.97''
(A:39.69" B:12.40")
Attention
Fit the Installation Plate and drill holes
in the wall according to the wall
structure and corresponding mounting
points on the installation plate
(Dimensions are in “mm” unless
otherwise stated).
Installation plate
Refrigerant pipe
hole (right) Ø 2.56"
4. At all times securing to the wall
studs is recommended.
Drilling the Hole
1. Determine the position of the
hole for the pipes using the
installation plate and drill the
pipe hole so that it is tilted slightly
downward.
2. Always use a pipe cover with an
opening when drilling.
Indoor unit
Wall
Outdoor unit
28"
0.2"-0.
Indoor unit installation
12
Connective pipe and drainage installation
Connective pipe
1. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel.
must be kept as it may
when relocating
The pipe cover
be used
the air
conditioner
to any other place.
2. For the rear-right-hand and rear-lefthand piping, install the piping as
shown in the sideward figure. Bend
the connective pipe to
be laid at
a height of 1.69" or less from
the wall.
Fix the end of the
connective pipe.
Pipe cover
(right)
Right piping
Indoor unit
outline
Pipe
holder
Rear right
piping
Connective
pipe
Pipe cover
(left)
Left piping
Rear left
piping
.69"
1
Drainage
1. Run the drain hose sloping
downward. Do not install the drain
hose as illustrated sideward.
2. When connecting extension drain
hose, insulate the connecting part
of extension drain hose with a
shield pipe, do not let the drain
hose slack.
Fastening the Indoor Unit
1. Pass the piping through the hole in
the wall.
2. Put the upper claw at the back of
the indoor unit on the upper hook of
the installation plate, move the
indoor unit from side to side to see
that it is securely hooked.
Do not block
water flow
by a rise.
Do not put the end
of drain hose into water.
Upper hook
Lower hook
Do not block
water flow
by a rise.
13
Indoor unit installation
3. Piping can easily be made by
lifting the indoor unit with a
cushioning material between the
indoor unit and the wall. Get it
out after finish piping.
4. Push the lower part of the indoor
unit up on the wall, Then move
the indoor unit from side to side,
up and down to check if it is
hooked securely.
Cushioning
material
Piping and wrapping
1. Bundle the tubing, connecting
cable, and drain hose with tape
securely and evenly as shown
in the sideward figure.
2. Because the condensed water
from rear of the indoor unit is
Indoor unit
Cable
connection
Ponding
box
Pipe room
Connective
pipe
gathered in ponding box and is
piped out of room, do not put
Drain hose
Wrapping
belt
anything else in the box.
Attention
1. Connect the indoor unit first, then the outdoor unit.
2. Do not allow the piping to let out from the back of the indoor unit.
3. Be careful not to let the drain hose slack.
4. Both of the auxiliary piping should be heat insulation.
5. Be sure that the drain hose is located at the lowest side of the bundle. Locating
at the upper side may cause drain pan to overflow inside the unit.
6. Never intercross nor intertwist the power wire with any other wiring.
7. Run the drain hose sloped downward to drain out the condensed water
smoothly.
Indoor unit installation
14
Loading...
+ 33 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.