Frigidaire FRRERADWRH61 Specs

Drop-In Cooktop
Overhead Hood
FPEC3085K S
FHWC3050RS 
Signature Features
PowerPlus® 3-Speed Fan
Powerful airflow at 3 different speeds — quietly moves up to 400 cu. ft. of air per minute.
Smudge-Proof
TM
Resists fingerprints and cleans easily.
30" Electric30" Under-Cabinet
Features
Nominal Width 30"
Style Canopy
Controls Push-Button
Air Discharge Vertical
Air Delivery (CFM) 400
Blower Type Fan
Sound Level (dBA) 75
Fan Speeds 3
1
4 PowerBright™ LED Lights
3-1/4" x 10" Rectangular
.33 kW
Cooktop Light(s)
Dishwasher-Safe Filter(s) Yes
Exhaust Duct External
Duct Required
Specifications
Product Dimensions –
Height 10-1/2"
Width 30"
Depth 20"
Voltage Rating 120V / 60Hz / 15A
Connected Load (kW Rating) @ 120 Volts
Amps @ 120 Volts 2.75
Shipping Weight (Approx.) 46
Sones Rating 3.0 – 6.6
1
  For use on adequately wired 120V, dedicated circuit having
2-wire service with a separate ground wire. Appliance must be grounded for safe operation.
NOTE: Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale. Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change.
Available in:
Dishwasher-Safe Filters
For consistently clean air circulation, use our removable, dishwasher safe filters.
PowerBrightTM LED Cooktop Lighting
Clear, bright view of your cooktop workspace with LED lighting for seamless meal preparation. Offers 3 different brightness levels.
Smudge-Proof™
Stainless
(S)
frigidaire.com
Under-Cabinet Vent Hood FHWC3050R Frigidaire Professional
30"
Height allowed from bottom
36" base
cabinet height
to floor
of hood canopy to cooking surface –
24" min. (elec.) / 27" min. (gas) / 30" sugg. max.
3 1/4" x 10" rectangular duct location
9"
10 1/2"
3"
Vent hood is vertically ducted outside
1
3
/4" x 10" rectangular duct. For detailed
using
duct preparation and installation specifications,
refer to installation instructions on web.
Filler strip mounting screw holes (4)
3"
Vertical duct cutout
Rear
5
/8" *
Wall
3"
Electrical access hole (in cabinet bottom)
2"-wide wood filler strips required for
recessed cabinet bottoms only
*From wall, NOT cabinet frame
Power supply locations (top & rear)
3
29 7/8"
13
7 3/4"
27 3/4"
Overhead Hood
FHWC3050RS 30" Under-Cabinet
Exhaust
Cabinet Bottom
11/4" dia.
3"
3"
1
1
/2" *
3
8
/8"
1
5
/4"51/4"
C
4"
L
/4"
Under-Cabinet Hood Specifications
Product Shipping Weight (Approx.) – 46 Lbs.
Under-Cabinet Installation – must be ducted vertically.
Ventilation system exhausts air outside, vertically through roof. (Refer to Ducting Option Specifications for outside ventilation.).
Sones Rating – 3.0 – 6.6
Voltage Rating – 120V / 60 Hz / 15 Amps
Connected Load (kW Rating) @ 120 Volts = .33 kW (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)
Amps @ 120 Volts = 2.75 Amps
Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale.
Makeup air systems may be required by local building codes when using ventilation systems greater than specified CFM of air movement. Specified CFM varies per locale.
Connect vent hood with copper wire only. (For installation pre-wired with aluminum wiring, refer to Product Installation Guide on web for correct wiring procedure.)
Locate vent hood away from strong draft areas, such as windows, doors or strong heating vents.
24" (electric) / 27" (gas) minimum installation height allowed from bottom of hood canopy to cooking surface; 30" maximum height suggested.
20"
4"
Ensure there is proper clearance within ceiling, wall or cabinet BEFORE making cutouts.
When installing vent hood under cabinets with recessed bottoms, two 2"-wide filler strips required with length and thickness determined by recess dimensions.
Framing for hood support MUST be capable of supporting 100 lbs.
30"
Ducting Option Specifications
Vent system MUST terminate outside through roof; do NOT terminate into attic or other enclosed area.
Exhaust Duct Required – 3-1/4" x 10" rectangular with 35' maximum vent length. Refer to Product Installation Guide on web for calculations needed to determine total duct length.
To provide efficient performance, length of vent system and number of elbows should be kept to minimum. Flexible vent greatly reduces performance and is NOT recommended.
Use 3-1/4" x 10" rectangular metal vent only – rigid metal vent recommended; plastic or metal foil vent NOT recommended.
For cold weather installation, additional backdraft damper and thermal break should be installed. Thermal break will minimize conduction of outside temperatures as part of the vent system with damper on cold air side of break, as close as possible to where vent system enters heated portion of house.
Refer to Product Installation Guide on web for detailed vent system preparation instructions.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
USA
10200 David Taylor Drive
CANADA
FHWC3050R 03/16 © 2016 Electrolux Home Products, Inc.
5855 Terry Fox Way
Charlotte, NC 28262
Mississauga, ON L5V 3E4
1-800-FRIGIDAIRE
1-800-265-8352
frigidaire.com
frigidaire.ca
Accessories information available
on the web at frigidaire.com
Specifications
subject to change.
Loading...