Drop-In Cooktop
Overhead Hood
FPEC3085K S
FHWC3050RS
Signature Features
PowerPlus® 3-Speed Fan
Powerful airflow at 3 different
speeds — quietly moves up to
400 cu. ft. of air per minute.
Smudge-Proof
TM
Resists fingerprints and cleans
easily.
30" Electric30" Under-Cabinet
Features
Nominal Width 30"
Installation Type Under-Cabinet
Style Canopy
Controls Push-Button
Air Discharge Vertical
Air Delivery (CFM) 400
Blower Type Fan
Sound Level (dBA) 75
Fan Speeds 3
1
4 PowerBright™
LED Lights
3-1/4" x 10"
Rectangular
.33 kW
Cooktop Light(s)
Dishwasher-Safe Filter(s) Yes
Exhaust Duct External
Duct Required
Specifications
Product Dimensions –
Height 10-1/2"
Width 30"
Depth 20"
Voltage Rating 120V / 60Hz / 15A
Connected Load
(kW Rating) @ 120 Volts
Amps @ 120 Volts 2.75
Shipping Weight (Approx.) 46
Sones Rating 3.0 – 6.6
1
For use on adequately wired 120V, dedicated circuit having
2-wire service with a separate ground wire. Appliance must
be grounded for safe operation.
NOTE: Always consult local and national electric codes. Check
local building codes for installation requirements, as they
may vary per locale. Refer to Product Installation Guide for
detailed installation instructions on the web at frigidaire.com.
Specifications subject to change.
Available in:
Dishwasher-Safe Filters
For consistently clean air
circulation, use our removable,
dishwasher safe filters.
PowerBrightTM LED Cooktop
Lighting
Clear, bright view of your
cooktop workspace with LED
lighting for seamless meal
preparation. Offers 3 different
brightness levels.
Smudge-Proof™
Stainless
(S)
frigidaire.com
Under-Cabinet Vent Hood
FHWC3050R
Frigidaire Professional
30"
Height allowed from bottom
36" base
cabinet height
to floor
of hood canopy to cooking surface –
24" min. (elec.) / 27" min. (gas) / 30" sugg. max.
3 1/4" x 10" rectangular
duct location
9"
10 1/2"
3"
Vent hood is vertically ducted outside
1
3
/4" x 10" rectangular duct. For detailed
using
duct preparation and installation specifications,
refer to installation instructions on web.
Filler strip mounting screw holes (4)
3"
Vertical duct
cutout
Rear
5
/8" *
Wall
3"
Electrical access hole (in cabinet bottom)
2"-wide wood filler strips required for
recessed cabinet bottoms only
*From wall, NOT cabinet frame
Power supply
locations (top & rear)
3
29 7/8"
13
7 3/4"
27 3/4"
Overhead Hood
FHWC3050RS 30" Under-Cabinet
Exhaust
Cabinet Bottom
11/4"
dia.
3"
3"
1
1
/2" *
3
8
/8"
1
5
/4"51/4"
C
4"
L
/4"
Under-Cabinet Hood Specifications
•
Product Shipping Weight (Approx.) – 46 Lbs.
•
Under-Cabinet Installation – must be ducted vertically.
•
Ventilation system exhausts air outside, vertically through roof.
(Refer to Ducting Option Specifications for outside ventilation.).
•
Sones Rating – 3.0 – 6.6
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = .33 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded for
safe operation.)
•
Amps @ 120 Volts = 2.75 Amps
•
Always consult local and national electric codes. Check local building
codes for installation requirements, as they may vary per locale.
•
Makeup air systems may be required by local building codes
when using ventilation systems greater than specified CFM of air
movement. Specified CFM varies per locale.
•
Connect vent hood with copper wire only. (For installation pre-wired
with aluminum wiring, refer to Product Installation Guide on web for
correct wiring procedure.)
•
Locate vent hood away from strong draft areas, such as windows,
doors or strong heating vents.
•
24" (electric) / 27" (gas) minimum installation height allowed
from bottom of hood canopy to cooking surface; 30" maximum
height suggested.
20"
4"
•
Ensure there is proper clearance within ceiling, wall or cabinet
BEFORE making cutouts.
•
When installing vent hood under cabinets with recessed bottoms,
two 2"-wide filler strips required with length and thickness determined
by recess dimensions.
•
Framing for hood support MUST be capable of supporting 100 lbs.
30"
Ducting Option Specifications
•
Vent system MUST terminate outside through roof; do NOT terminate
into attic or other enclosed area.
•
Exhaust Duct Required – 3-1/4" x 10" rectangular with 35' maximum
vent length. Refer to Product Installation Guide on web for calculations
needed to determine total duct length.
•
To provide efficient performance, length of vent system and number
of elbows should be kept to minimum. Flexible vent greatly reduces
performance and is NOT recommended.
•
Use 3-1/4" x 10" rectangular metal vent only – rigid metal vent
recommended; plastic or metal foil vent NOT recommended.
•
For cold weather installation, additional backdraft damper and thermal
break should be installed. Thermal break will minimize conduction of
outside temperatures as part of the vent system with damper on cold
air side of break, as close as possible to where vent system enters
heated portion of house.
•
Refer to Product Installation Guide on web for detailed vent system
preparation instructions.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
•
USA
10200 David Taylor Drive
•
CANADA
FHWC3050R 03/16 © 2016 Electrolux Home Products, Inc.
5855 Terry Fox Way
•
Charlotte, NC 28262
•
Mississauga, ON L5V 3E4
•
1-800-FRIGIDAIRE
•
1-800-265-8352
•
frigidaire.com
•
frigidaire.ca
Accessories information available
on the web at frigidaire.com
Specifications