MOTOR DOOR LATCH
L1 IN
MEAT PROBE
terre à la caisse
NOTICE: This service data sheet is intended for use by persons having electrical and mechanical training and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade. The manufacturer cannot be responsible, nor assume any liability, for injury or damage of any kind arising from the use of this data sheet.
IMPORTANT NOTE: This unit includes an EOC (electronic oven control). This board is not eld-repairable.
Verify the unit has the proper oven relay board, oven user interface board, and touch panel based on the model number and parts catalog.
Safe Servicing Practices
1. Do not attempt a product repair if you have any doubts as to your ability to complete it in a safe and satisfactory manner.
2. Before servicing or moving an appliance, remove power cord from electric outlet, trip circuit breaker to
O󰀨, or remove fuse.
3. Never interfere with the proper installation of any safety device.
WARM ZONE
CONVECTION FAN
OVEN LIGHT
COOLING FAN
L1
NEUTRAL
1
J8
K8 K6 K5
L1
L3
J2
1
L2
DOOR SWITCH NO
MOTOR DOOR LATCH NO
GROUND
TEMP PROBE
MEAT PROBE TEMPERATURE VS RESISTANCE TABLE
Temperature Probe Resistance
77 °F / 25°C 50.020 Kohm +/- 6%
122 °F / 50°C 18.020 Kohm +/- 5%
176 °F / 80°C 6.290 Kohm +/- 5%
212 °F / 100°C 3.400 Kohm +/- 5%
K7
K9
MACS1
1
GROUND
COMM
L2 OUT
L2 IN
J6
K1
DLB
13V
K2
MACS2
1
L1 OUT
CIRCUIT
ANALYSIS
MATRIX
Bake X X X X X
Broil X X
Conv. Bake X X X X X
Conv. Roast X X X X X
Clean X X X
Locking X
Unlocking X
Light X
Door Open X
Door Closed X
NOTES: Bake, broil, and convection elements alternate cycles. Convection fans may run during preheat and may run intermittently during non-convection functions to improve cooking performance.
SERVICE DATA SHEET
p/n 808532646 Rev A (1902)
4. Use only replacement parts specied for this appliance. Substitutions may not comply with safety standards set for home appliances.
5. Grounding: The standard color coding for safety ground wires is green or green with yellow stripes. Ground leads are not to be used as current carrying conductors. It is extremely important that the service technician reestablish all safety grounds prior to completion of service. Failure to do so will create a potential hazard.
6. Prior to returning the product to service, ensure that:
All electric connections are correct and secure.
All electrical leads are properly dressed and secured away from sharp edges, high-temperature
components, and moving parts.
All uninsulated electrical terminals, connectors, heaters, etc. are adequately spaced away from
all metal parts and panels.
All safety grounds (both internal and external) are correctly and securely reassembled.
All panels are properly and securely reassembled.
Temperature Adjustment
Refer to the Use & Care Manual for directions on how to adjust the oven temperatures.
BAKE ELEMENT
J7
K3
K4
BROIL
CONVECTION ELEMENT
J5
L1 IN
J11
1
Elements
BakeJ6BroilK4Conv.
J7
ÉCHELLE DU DÉTECTEUR DE TEMPÉRATURE À RÉSISTANCE
Temperature
Température °F (°C)
32 ± 1.9 (0 ± 1.0)
75 ± 2.5 (24 ± 1.3) 250 ± 4.4 (121 ± 2.4) 350 ± 5.4 (177 ± 3.0) 450 ± 6.9 (232 ± 3.8) 550 ± 8.2 (288 ± 4.5) 650 ± 9.6 (343 ± 5.3)
900 ± 13.6 (482 ±7.5)
Probe circuit to case ground
Circuit de la sonde mise à la
Door Motor
J8-1
RTD SCALE
Light J8-4
Resistance
Résistance (ohms)
1000 ± 4.0 1091 ± 5.3
1453 ± 8.9 1654 ± 10.8 1852 ± 13.5 2047 ± 15.8 2237 ± 18.5
2697 ± 24.4
Open circuit/infinite resistance
Circuit ouvert/résistance infinie
Conv. Fan
J8-3
Door
Switch
J8-1
DLB L2
out K1
ELECTRONIC OVEN CONTROL (EOC) FAULT CODE DESCRIPTIONS
Fault Code
F01 F02 F04 F05
F03 The oven user interface board is incorrectly
F10 Oven temperature runaway: the cavity tem-
F11 Stuck key: a key has been detected has
F12 Keyboard conguration alarm: the oven
F13 Data written to non-volatile memory has
F15 Keyboard error Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
F16 The oven user interface board cannot read
F17 The oven user interface board is unable to
F18 Oven relay board failure (wiggler) Replace the oven relay board.
F19 The oven user interface board is unable to
F22 Communication failure between the oven
F23 Communication failure between the oven
F25 F27
F28 F29
F30 Open oven temperature sensor (RTD) 1. Check probe circuit wiring for possible open or short condition.
F31 Shorted oven temperature probe (RTD)
F33 Meat probe temperature sensor shorted or
F50 A/D Out of Range: the oven relay board is
F90 Motor Door Lock mechanism failure. The
F95 Motor Door Lock mechanism failure. The Mo-
F96 The oven door has been detected open
F97 MDL invalid state. Relay board (OVC)
Description of Error Code Suggested Corrective Action
Touch panel failure Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
congured.
perature has been detected in excess of the maximum safe operating temperature.
pressed continuously for 30 seconds or more.
user interface board received from the touch panel a key code that does not match the key map.
failed verication
the potentiometers.
congure the touch panel.
congure the oven relay board
user interface board and the oven relay board
user interface board and the glass touch panel
The communication between the over user interface and the oven relay board cannot be initiated.
The communication between the over user interface and the touch panel cannot be initiated.
too hot
unable to read the status of the switches
(door, MDL)
oven control does not see the Motor Door
Lock running.
tor Door Lock does not stop running or the Lock Switch sends an invalid signal.
during a Self Clean cycle.
sensed the motor door lock in a state it should not be in according to the user interface board.
Replace the control assembly (UIB and touch panel). Make sure you install the latest revision available for this model.
1. If oven is overheating, disconnect power. Check oven temperature probe (RTD) and replace if necessary.
2. If the oven temperature probe is good and if oven continues to overheat when power is reapplied, replace the oven relay board.
1. If a key was pressed inadvertently for a long time this error code will be displayed. Make sure there is nothing (water, utensils) in contact with the
keyboard. The fault code should go away once the key is released and the Stop key is pressed. If the F011 error comes back when a key is pressed it
means the error condition is still there. If the F011 error does not come back it means the error condition is gone and the oven can be used.
2. If the fault code cannot be cleared, test the wiring harness between oven user interface board (connector I2C1 or I2C2) and touch panel (connector I2C1 or I2C2).
3. If the fault code cannot be cleared and the wiring is good, the touch panel is most likely defective: replace the control assembly (UIB and touch panel).
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
Disconnect power, wait 30 seconds and reapply power. If fault returns upon power-up replace the control assembly (UIB and touch panel).
1. Verify that potentiometers are in OFF position correctly, disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify harness going to the POTS connector of the user interface board to both potentiometer components.
3. If fault persists, replace potentiometers.
4. If fault persists, replace the control assembly (UIB and touch panel)
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify harness going to I2C1 or I2C2 connector of the touch panel.
3. If fault persists, replace the control assembly (UIB and touch panel)
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify connection between the oven user interface board (MACS1 or MACS2 connector) and the oven relay board (connector J3 or
J4).
3. If fault persists, replace the control assembly (UIB and touch panel)
4. If fault persists, replace the relay board.
1. Disconnect power, wait 30 seconds and reapply power. Check if error condition is still there.
2. Test wiring harness between oven user interface board (connector MACS1 or MACS2) and oven relay board (connector J3 or J4).
3. If wiring harness is good replace oven relay board.
4. If the problem persists replace the control assembly (UIB and touch panel).
1. Disconnect power, wait 30 seconds and reapply power. Check if error condition is still there.
2. Test wiring harness between oven user interface board (connector I2C1 or I2C2) and touch panel (connector I2C1 or I2C2).
3. If wiring harness is good replace touch panel.
4. If the problem persists replace the control assembly (UIB and touch panel).
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify connection between the oven user interface board (MACS1 or MACS2 connector) and the oven relay board (connector J3 or
J4).
3. If fault persists, replace relay board.
4. If fault persists, replace the control assembly (UIB and touch panel).
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault returns, verify touch panel is connected (verify harness going to I2C1 or I2C2 connector) and is getting power from the oven user interface.
3. If fault persists, replace the control assembly (UIB and touch panel).
2. Verify RTD resistance at room temperature (compare to probe resistance chart). If resistance does not match the chart, replace the RTD probe.
3. If the problem persists replace the oven relay board.
1. The error is triggered if the meat probe sees a temperature in excess of 392°F. Make sure the meat probe was not used in such way that it could have seen such temperature. If the tip of the probe is not inserted in the meat it will see the cavity temperature, which can be higher than 392°F (depending on the setpoint) and trigger the alarm.
2. When the meat probe is connected to the socket inside the oven cavity, if the meat probe is not fully inserted into the socket it may short the contacts and cause the error. Make sure the probe is inserted as much as it can.
3. Verify meat probe resistance at room temperature. Compare to meat probe resistance chart. If the meat probe does not match the chart, replace it.
4. If the above steps failed to correct the problem, replace the oven relay board.
1. Check to ensure that the connections between the door switch, MDL and temp probes are properly connected. This includes all splices and junctions.
2. If the above step failed to correct the problem, replace the oven relay board.
1. Disconnect power to the unit, wait 30 seconds, then reapply power. Try again to make the door lock or unlock (ex: initiate a Lockout or a Clean cycle).
2. Check if the Lock Motor is running or not. If it is not running, test the wiring between the Lock Motor and the oven relay board. If the wiring is good, check if there is 120VAC at the motor when it is expected to run to see if the failure originates from a bad motor (120VAC present but not turning) or
a problem with the relay board (J20 pin 10 on the oven relay board is the output to the Lock Motor). The Lock Motor can also be tested by applying 120VAC directly to the motor (unplug it from the relay board rst). If the Lock Motor does not run when 120VAC is applied replace the Lock Motor Assembly. If it is the relay board that does not provide 120VAC to the Lock Motor replace the oven relay board.
3. If the Lock Motor is running but the oven control cannot nd the locked or unlocked position (ex: motor turns continuously until F90 fault code is generated) the Lock Switch needs to be veried. Check wiring between Lock Switch and oven relay board. Verify with ohmmeter if the switch makes contact properly (verify continuity with ohmmeter when the switch is pressed). If the Lock Switch is defective replace the Motor Lock Assembly.
4. If all above steps failed to correct the situation, replace the oven relay board.
1. The problem can be caused by a faulty Lock Switch or by a defective oven relay board. If the Motor Door Lock is always running (as if the relay controlling it is stuck closed) replace the oven relay board.
2. If the motor is not always running replace the Motor Lock Assembly.
1. This error occurs if the door switch has lost its contact during a Self Clean cycle. Make sure the oven door closes well and fully presses on the door
switch plunger when the door is locked, and no one attempted to pull on the oven door during the Self Clean cycle.
2. Test continuity of wiring between the door switch and the oven relay board, make sure the door switch is well connected. With an ohmmeter, verify the switch is closed when the plunger is pressed. If the door switch is found to be defective replace the door switch.
3. If the switch and wiring are good and the problem persists, replace the oven relay board.
1. Disconnect power to the unit, wait 30 seconds, then reapply power.
2. If fault persists, replace motor door lock.
3. If fault persists, replace the oven relay board.