Circuit diagram:
Malfunction display:
1 Indoor air temp sensor open/short 8-segment display ‘F1’, with STATUS light flash 1
times and off 3 sec, repeat
2 Indoor coil sensor open or short 8-segment display ‘F2’, with STATUS light flash 2
times and off 3 sec, repeat
3 Outdoor coil sensor open/short 8-segment display ‘F4’, with STATUS light flash 3
times and off 3 sec, repeat
4 Freeze Guard protection 8-segment display ‘FP’
5 Indoor coil freeze protection STATU light flash 5 times and off 3 sec, repeat
6 Outdoor coil high temp protection STATU light flash 6 times and off 3 sec, repeat
7 Defrost (heat pump type) STATU light flash 7 times and off 3 sec, repeat
8 Indoor coil high temp protection STATU light flash 8 times and off 3 sec, repeat
9 Thermostat wiring error STATU light flash 9 times and off 3 sec, repeat
10 High pressure protection (optional) 8-segment display ‘E1’, (the highest display grade)