FRIGIDAIRE FRP77ETT3R User Manual

66129907342 (Dec.2010)
SAFETY CONSIDERATIONS
Recognize safety information. This is the safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.
Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
! WARNING
!
WARNING
PERSONAL INJURY AND/OR PROPERTY DAMAGE HAZARD
Failure to follow this warning could result in personal injury, death and/.or property damage. For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
l This unit must be properly installed in accordance with the Installation Instructions before it is used. l Immediately repair or replace all electric service cords that have become frayed or otherwise
damaged.
l Unplug or disconnect the unit at the fuse box or circuit breaker before making any repairs.
NOTE: We strongly recommend that any servicing be performed by a qualified professional.
GENERAL INFORMATION
Frigidaire package terminal air conditioners and heat pumps provide a high standard of quality in performance, workmanship, durability and appearance as they heat and cool the occupied air space year round.
This manual provides information for ease of installation, operation and maintenance. All models are designed for through--the--wall installation. Separate installation instructions are included
with all accessory components.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT: Save these instructions for local inspector's use. IMPORTANT: Observe all governing codes and ordinances.
NOTE TO INSTALLER
Be sure to leave these instructions with the owner.
NOTE TO OWNER
Keep these instructions for future reference. Be sure to write down the model and serial number on the space provided on the product registration card. The model and serial number can be located on the serial number plate attached to the unit. These numbers are required for service. (See Fig. 1.)
SERIAL No.: IK00700001 DATE: 03/11
FOR SERVICE CALL FRIGIDAIRE 1-866-942-1567
PACKAGED TERMINAL
AIR CONDITIONER
MODEL:
0
ENG:
Made in China
ELECTRICAL
VOLTS
Hz, PH.
COOLING DATA
BTU-
EER-
AMPS­WATTS-
ELECTRIC HEATING
BTU-
AMPS-
WATTS-
DESIGN PRESSURE
LOW- PSIG
HIGH- PSIG
R410A- OZ
Energy Performance Rendement Energetique
Warning:Use on Single Outlet Circuit Only
PACKAGED TERMINAL AIR CONDITIONER
UL FILE NUMBER:SA33529
ELECTROLUX HOME PRODUCTS
Charlotte, NC USA
2
Fig. 1 – Sample Data Information Plate
2010 Electrolux Home Products, Inc. All rights reserved.
UNIT FEATURES
This unit has many exciting features which are different from those found on standard PTAC models. The owner must be familiar with these features in order to fully understand the operation and capability of the unit. Intelligence -- Your unit has an on board computer that utilizes real time diagnostics to prolong the life of your unit. There is an LED indicator on the control board, behind the front panel, that will flash an error code if the unit has detected some kind of faulty condition. In many cases, the unit will automatically clear the fault condition and continue operating with no interruption. In some cases, the condition cannot be cleared and the unit will require service. In those cases, an “Fx” failure mode will be displayed on the digital display. For a detailed list of all error codes and “Fx” conditions, see Table 5 (page12) ­Status LED Indicator Definitions for further details. Memory -- Your unit also has memory. If power is lost, all of the control settings (setpoint, mode, fan speed, on/off and configuration) are remembered. So when power is restored, the unit will start back up in the mode (and configuration) it was in, when power was lost. Quiet Design -- Not only does the unit have 2 fan motors and a tangential blower wheel for optimum sound, the indoor fan will always run a minimum of 10 seconds before the compressor, to help reduce the sound of the compressor starting. Random Compressor Restart -- To help prevent power surges after a power outage ( starting at the same time), the compressor is equipped with a 2 minute 45 second to 3 minute 15 second random restart delay feature. Whenever the unit is plugged in, or power has been restarted, a random compressor restart will occur to help avoid power surges. Compressor Protection -- To prevent short cycling of the compressor and maximize it's life, there is a random start--up delay of 3 minutes on the compressor and a minimum compressor run time of 3 minutes. Automatic Room Freeze Protection -- This protection feature will automatically ensure the indoor temperature does not fall below freezing. When your PTAC is configured for freeze protection (which is the default condition), then whenever power is supplied to the unit, if the unit senses temperature below 40°F, the fan motor and electric heater are turned on and will warm the room to 50°F. Freeze protection can be switched off (please see page feature off (see section on unit configuration).
Automatic Quick Warm--Up (for heat pump models only) below the set point temperature, the reverse cycle heat is shut for one cycle, until room temperature rises.
9), change the configuration switch to turn the
-- If the room temperature falls to 5°F
off and the electric strip heat is turned on
Fig. 2
many PTACs
Dual-8 Display and LED Display -- Two 8-segment nixie tubes, 13 LED indicators (They are HIGH, MED, LOW, AUTO, COOL, FAN, HEAT, ON/OFF, SETOPINT, INDOOR, STATUS and TIMER)
1. Mode indicator display: When the air conditioner operates in a certain mode, the corresponding mode indicator will be lit;
2. The ON/OFF indicator is in green when the controller is ON and in red when controller is OFF.
3. Fan speed display: When air conditioner operates at high, medium, low or auto fan speed, the corresponding indicator will be lit.
4. Dual-8 display: Ambient temperature can also be displayed in cooling and heating modes through setting the keypad. Under cooling or heating mode, the dual-8 will display the set temperature (the dual-8 will display indoor ambient temperature under fan mode).
5. If the display data has three bits, the dual-8 will display “ten's digit”+ “unit's digit” at first and then display “BLANK”+ “hundred's digit”.
Fan Configure for Optimization of Selected Application -- The unit can be optimized to selected
application by configuring the fan to run in continuous mode or cycle on and off with the compressor and electric heater (can be different for both heating and cooling modes). In cycle mode, the fan will continue to run after the compressor or electric heater stops in order to blow off any residual heat or cool left on coil.
2010 Electrolux Home Products, Inc. All rights reserved.
3
INSTALLATION
Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under Warranty.
CHASSIS INSTALLATION
When units are shipped with a sleeve:
1.Remove shipping tape if they are applied.
2.Remove front panel. See Fig.10. Unscrew four screws which connect the main unit with sleeve. The screws location can be referred to Fig.11.
3.
4.Pull out the unit from the wall sleeves.
5.Install sleeve into the wall (please see Installation Instructions of PTAC Sleeve for details).
Note: We recommend always to use a Frigidaire sleeve.
When units are shipped without a sleeve:
In applications where unit is a replacement, it is recommended that a Frigidaire sleeve be used. Your product can retrofit General Electric, Amana, Trane, and Friedrich sleeves/grilles (be sure outdoor grille is installed on the sleeve). See Table 3 for details. For any sleeve retrofit applications, be sure that the foam seals (factory - installed on the tube sheets) provide a good seal between the grille and outdoor coil tube sheets. These foam seals provide a barrier that stops air from the inside mixing with air on the outside (known as air recirculation).
UNIT DAMAGE AND/OR OPERATION HAZARD
Failure to follow this caution may result in equipment damage or improper operation. For retrofit applications, foam seals on outdoor coil tube sheets must make a seal between the coil and the grille or loss of performance and premature damage to the major components can result.
Table 3—Retrofit Wall Sleeves
!
CAUTION
! CAUTION
Manufacturer Wall Sleeve Part Number
General Electric
Metal Sleeve RAB71 Plastic Sleeve RAB77
Amana Metal Sleeve WS900B
Trane Metal Sleeve SLV149
T---Series Metal 111/2---in. Deep Wall
Friedrich
* FR-SLEEVE-EXT accessory is required for retrofit into Friedrich (T - Series) wall sleeves.
Sleeve* Standard Depth Wall Sleeve 16 X 42 X 133/4---in. PXWS
COIL TUBE SHEETS
OUTDOOR ORIFICE
WIRE SCREEN
DISCHARGE GRILLE
INDOOR-AIR INLET FILTERS
INDOOR COIL
FR ONT PANEL
2010 Electrolux Home Products, Inc. All rights reserved.
Fig. 3 Unit Components
BASEPAN
ACCESSOR
OUTDOOR
ACCESSORY
WALL
SLEEVE
GRILLE
5
INSTALLATION
RETROFIT SLEEVE PREPARATION
IMPORTANT: Inspect wall sleeve thoroughly prior to installation. Manufacturer does not assume responsibility for costs or damages due to defects in sleeve or for improper installation.
!
! WARNING
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death. Disconnect all power to unit to avoid possible electrical shock during installation.
Remove any existing foam baffles that are installed on competitive outdoor grille, if present. See Fig. 4.
GE Sleeves Only GE Metal Wall Sleeve - GE metal sleeve is interchangeable with Frigidaire wall sleeve. See Fig. 5. GE Plastic Sleeve - Remove bottom seal from plastic sleeve. See Fig. 6.
INSTALLATION OF A FRIGIDAIRE WALL SLEEVE USING A NON- FRIGIDAIRE GRILLE
Using a Frigidaire wall sleeve with a non-Frigidaire grille requires installation of an Accessory Baffle Kit (see Fig. 7), which ensures a good seal between the unit and exterior grille to prevent air recirculation. Air
recirculation is a large contributor to performance loss and premature damage to major components. Notes: Frigidaire stamped grille is interchangeable with GE'S.
BAFFLES
Fig.4–Remove Existing Outdoor Grille Baffles o n Competitive Grille
SLEEVE
BOTTOM SEAL
Fig. 6 – Remo ve Bott om Seal From GE Plastic Sleeve
2010 Electrolux Home Products, Inc. All rights reserved.
6
Fig.5-GE Metal Sleeve
Fig. 7–Accessory Baffle Kit
Note: Con tac t you r units s upp lie r to ge t th e kit, the actual baffle kit may look different from the image shown above.
Loading...
+ 14 hidden pages