Simple controls allow guests to
customize their settings, while quiet,
uniform air movement keeps rooms
comfortable.
Smart Self-Check
Provides nine diagnostic points for selfcheck and correction of fault conditions.
Eco-Friendly
Frigidaire® uses R-410A refrigerant that’s
not harmful to the earth’s ozone layer
and meets U.S. Environmental Protection
Agency requirements.
Eortless™ Operation
Simple, intuitive room controls are easy
for guests to operate — ensuring a
relaxing, more comfortable stay. Features
like Effortless™ Restart and Ready-Select®
controls reduce maintenance calls.
Signature Features
SilentDesign™
Sound reduction package.
Eortless™ Maintenance
With Frigidaire’s reputation for durability,
easy maintenance, availability of reliable
parts and service you can count on,
you can be sure that you’re getting the
highest-quality performance.
Energy-Saver Option
This function effortlessly maximizes
energy efficiency while keeping guests
comfortable.
Eortless™ Temperature
Control
Frigidaire® air conditioners maintain the
preset room temperature so the room
remains comfortable at all times and
helps control energy levels.
Performance
Cool
Electric Heater
BTUs
15,000 / 14,600
17,000 / 13,900
frigidaire.com
Performance
B
A
C
Frigidaire
R= Normal no accessories
A= Seacoast no accessories
S= Normal w/ accessories
B= Seacoast w/ accessories
FRP90ETT2R
Room
PTAC
Platform
Design Year
T= 2010
U= 2011
BTU
77= 7,700
90= 9,000
12= 12,000
15= 15,000
Heat Type
E= Electric
P= Heat Pump
Voltage
2= 230/208V
3= 265V
PTAC Nomenclature
Plug Type (NEMA)
6-30P
BTU (Cool)
BTU (Electric Heater)
Dehumidification (Pints / Hour)
Cool Area (Sq. Ft.)
Energy Eciency Ratio
15,000 / 14,600
17,000 / 13,900
3.5
875
9.7 / 9.8
Electrical
Volts
Amps (Cool)
Amps (Electric Heater)
Watts (Cool)
Watts (Electric Heater)
Cable Included
Length of Power Cord
Circuit Breaker
Plug Type (NEMA)
230 / 208
6.7 / 7.5
21.5 / 20.5
1,530 / 1,510
5,000 / 4,087
Yes
5.5'
30A
LCDI (6-30P)
Features
Electronic Controls
Front Desk Control Ready
Fan Speeds (Cool / Fan / Heat)
Noise Level Indoors (High / Med / Low)
Quiet Start-Up
Low Voltage Start-Up
Random Restart Protection
Eortless™ Auto Freeze Protection
Energy Save
24-Hour On / O Timer
Air CFM (High / Med / Low)
Air Direction Control
Air Intake
Filter Type
Filter Access
Fin Coating
Slide-Out Chassis
Commercial Grade Warranty
1
Ready-Select® Controls
Yes
3 / 3 / 3
53 / 52 / 51
Yes
Yes
Yes
Yes
Yes
Yes
315 / 295 / 275
Auxiliary 2-Way
Fresh or Recycled
Nylon Mesh
Slide-Out
Normal
Yes
Yes
Certifications
Safety Certification
Performance
UL, CUL & CSA
AHRI & CEC
Specifications
Refrigerant
Charge
Shipping Weight (Approx.)
1
Warranty 5 year sealed system / 1 year full parts and labor.
NOTE: For planning purposes only. Always consult
local and national electric codes. Refer to Product
Installation Guide for detailed installation instructions
on the web at frigidaire.com.
Product Dimensions
A - Height
B - Width
C - Depth
Max. Wall Thickness
2
Unless the PTAC unit is installed with a wall sleeve.
•
frigidaire.com
•
frigidaire.ca
16"
42"
13-13/16"
13-13/16"
Wall Cutout Dimensions
Height
Width
2
16-5/16"
42-3/16"
Accessories information available
on the web at frigidaire.com
Specifications
subject to change.
Front Panel
Chassis
Accessory
Wall Sleeve
Accessory
Outdoor Grille
Wall Sleeve
Adapter
PTAC - Heat Pump and Electric Heat models_Prod Specs
Rearward Slope
Outside Wall
1/4
" Slope
Inside Wall
Product Dimensions
Height
Width
Depth
Max. Wall Thickness
16"
42"
13-13/16"
13-13/16"
Wall Cutout Dimensions
Height
Width
16-5/16"
42-3/16"
Plug Type (NEMA)
6-30P
Packaged Terminal Air Conditioner (PTAC)
FRP15ETT2R Air Conditioner / Electric Heater
PTAC Specifications
•
Product Shipping Weight (approx.) – 141 Lbs.
•
An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current
edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances.
Unit equipped with 230/208V 3-wire power supply cord, NEMA plug
type 6-30P, approximately 66" long.
•
In order for condensate water to drain properly inside the unit, the
sleeve must be installed properly: Level from right to left with a slight
1/4" rearward pitch from the indoor side to the outdoor side as shown in
the illustration above. Refer to the Installation Instructions on the web.
•
The drain kit listed on the Frigidaire® PTAC Accessories page can
be used for an internal or external drain. This applies to new and
replacement installation.
New Installation
•
For new installation, Frigidaire® PTAC Sleeves are available and
recommended for proper installation. See accessories pages for
sleeve options.*
•
Standard PTAC installation requires 13-13/16" maximum wall thickness,
unless a wall sleeve is used.
•
If the PTAC unit protrudes more than 4", then it is suggested that it be
installed with a subbase. See accessories pages for subbase options.
When replacing existing PTAC with new unit, refer to Product
Installation Guide on web to identify existing wall-sleeve manufacturer
and size compatibility. If proper installation and slope are suspect,
then correct installation of Frigidaire® PTAC Sleeve options
recommended.
•
For any sleeve retrofit application, be sure that the foam seals
(factory-installed on the tube sheets) provide a good seal between
the grille and the outdoor coil tube sheets. These foam seals provide
a barrier that stops air from the inside mixing with air on the outside
(known as air recirculation).
•
Using Frigidaire® wall sleeve with Non-Frigidaire grille requires
installation of an Accessory Baffle Kit, which ensures a good seal
between the unit and exterior grille to prevent air recirculation. Air
recirculation is a large contributor to performance loss and premature
damage to major components.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
*See Frigidaire® PTAC accessories pages attached for optional accessories.
Specifications
subject to change.
Packaged Terminal
Air Conditioner (PTAC)
ACCESSORIES
Metal Wall Sleeves and Accessories
The electro-galvanized steel used to make this metal sleeve resists
corrosion. The white powder coating matches the color of the Frigidaire®
PTAC. Sliding keyhole grille attachments at the back enable easy, oneperson installation from the inside.
5304482701 — Steel Wall Sleeve, Insulated
This extended width wall sleeve is fully insulated and made of galvanized
steel. It is welded and protected with baked-on enamel. Welded areas
are protected with a sealing compound to prevent rust.
5304483759 — Metal Wall Sleeve Extension, Insulated, 16"
5308815304 — Metal Wall Sleeve Extension, Insulated, 18"
5308815305 — Metal Wall Sleeve Extension, Insulated, 24"
5304483760 — Metal Wall Sleeve 3" Adapter
Polymer Wall Sleeves
The universal polymer wall sleeve utilizes fiberglass reinforced
polyester compound to produce a durable, non-corrosive, wall case
that provides superior sound absorption, reduces heat loss, and
prevents sleeve sweating.
The polymeric architectural outdoor grille blends with most
building exteriors. Its durable design offers protection, has an
enhanced appearance and provides superior weather resistance.
The extruded aluminum outdoor grille will enhance the appearance of any
building. The grilles are made of a durable, anodized aluminum that resists
weather. Installs easily onto the Frigidaire® metal wall sleeve, thanks to the
sliding keyhole attachment.
The condensate drain kit is used to control condensate water from
the packaged terminal unit. This universal drain kit can be used for
exterior or interior drain systems.
In order to ensure a healthy room environment the air filters should be
changed periodically. By changing the air filters, airflow, temperature
control and energy efficiency is maintained.
5304482892 — Air Filters, 10 Pack
Decorative Subbases & Supports
The non-electrical subbase is made of heavy gauge steel to provide
support for the wall sleeve. The subbase is designed to mount directly
to the wall sleeve. Leveling legs attach easily to the wall sleeve and
offer accurate leveling and support for units.
5308815315 — Decorative Subbase, Black
5304480575 — Leveling Legs
Electrical Subbases
The electrical subbase provides the same features as the
non-electrical subbase, plus a factory-installed electrical
junction box containing a receptacle for corded packaged
terminal air conditioner units.
5304482886 — Electrical Subbase-230V-15A, Black
5304482887 — Electrical Subbase-230V-20A, Black
5304482888 — Electrical Subbase-230V-30A, Black
5304482889 — Electrical Subbase-265V-15A, Black
5304482890 — Electrical Subbase-265V-20A, Black
5304482891 — Electrical Subbase-265V-30A, Black
5304482698 — Subbase Disconnect Switch, 265V
Hardwire Kits
Hardwire kits allow your PTAC to be
permanently connected to a power
source. The kit includes a 36" metal
conduit and connector.
Wireless Wall Thermostats
The wireless Effortless™ Temperature Control wall thermostat allows control
without having to worry about wiring. Easy to install and easy to use. Large
intuitive LCD screen improves the user interaction.
5304482699 — Wireless Digital Thermostat, Non-Programmable
5304482XXX — Antenna for Wireless Wall Thermostat
With the Effortless™ Temperature Control wired wall thermostat,
comfort and precision is in your hands. Programmable or nonprogrammable, this thermostat offers autochangeover, 2-stage
heating and cooling, as well as emergency heating mode
(for Heat Pump).
5304482700 — Wired Digital Wall Thermostat, Programmable
5304483050 — Wired Digital Wall Thermostat, Non-Programmable
5304484139 — Transfer Cable (For Quick Programming of
Wired Thermostats)
FR_PTAC_ACC 08/11