Home Comfort
FRA144HT2
Through-The-Wall
Air Conditioner
Product Dimensions
Height 14-1/2"
Width 24"
Depth 20-1/2"
More Easy-To-Use Features
Multi-Speed Fan
Features three different fan speeds, for
more cooling flexibility.
Sleep Mode
Quiet operation keeps you cool without
keeping you awake. Plus, Sleep Mode
gradually increases room temperature
after being activated.
Quickly Cools
Quickly cool a room on hot days.
Comfort Control Design
Easily control the direction of your cool air,
wherever your unit is.
Eortless™ Restart
Automatically resumes operating at its
previous settings when power is restored
to your unit.
Signature Features
Eortless™ Remote
Temperature Control
A themostat located on your air
conditioner’s remote control precisely
maintains preset room temperature, so
you will remain comfortable at all times.
Remote Control
Allows you to precisely control the
temperature and fan speed from across
the room.
Ready-Select® Controls
Easily select options with the touch of a
button.
Eortless™ Clean Filter
Our antibacterial filter reduces bacteria,
room odors and other airborne particles
for a cool, comfortable environment.
Clean Filter Alert
Notifies you when your filter needs to be
cleaned.
Power Cord
Comes with an extra long three-prong
cord that makes extension cords
unnecessary.
SpaceWise® Adjustable Design
Optional Side Panels
Extend so you can adjust your unit to fit
your window.
24-Hour On/O Timer
Keep things cool on your schedule.
Performance
Cool
BTUs
14,000 / 13,600
frigidaire.com

Performance
BTU (Cool)
Dehumidification (Pints / Hour)
Cool Area (Sq. Ft.)
Energy Eciency Ratio
14,000 / 13,600
4.3
640
9.0
Electrical
Volts
Amps (Cool)
Watts (Cool)
Length of Power Cord
Plug Type (NEMA)
240 / 208
7.4 / 8.4
1,550 / 1,520
6'
LCDI (6-15P)
Features
Electronic Controls
Fan Speeds (Cool / Fan)
Low Voltage Start-Up
Auto Cool Function
Energy Save
Sleep Mode
Filter Check
24-Hour On / O Timer
Clean Air Ionizer
Remote Control
Air CFM (High / Med / Low)
Air Direction Control
Fresh Air / Exhaust Vent / Closed
Filter Type
Filter Access
Slide-Out Chassis
1
Warranty
Ready-Select® Controls
3 / 3
Yes
Yes
Yes
Yes
Yes
Yes
Full-Function Remote T’Stat
302 / 279 / 252
4-Way
No / No / Yes
Antibacterial Mesh
Slide-Out
Yes
Optional Accessories
Through-The-Wall 18" Sleeve Kit
Trim Kit (for larger existing sleeve)
Architectural-Style
Exterior Louvered Grille
PN # EA108T
PN # EA120T
PN # EA109T
Certifications
Performance
AHAM
Specifications
Refrigerant
Shipping Weight (Approx.)
1
Warranty 5 year sealed system / 1 year full parts and labor.
R410a
93 Lbs.
Home Comfort
FRA144HT2 Through-The-Wall Air Conditioner
USA
CANADA
FRA144HT2 04/11 © 2011 Electrolux Home Products, Inc. Printed in the U.S.A.
•
10200 David Taylor Drive
•
5855 Terry Fox Way
•
Charlotte, NC 28262
•
Mississauga, ON L5V 3E4
•
1-800-FRIGIDAIRE
•
1-800-265-8352
NOTE: For planning purposes only. Always consult local and national electric codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Product Dimensions
A - Height
B - Width
C - Depth
D - Max. Wall Thickness
•
frigidaire.com
•
frigidaire.ca
14-1/2"
24"
20-1/2"
18"
Wall Cutout Dimensions
Height
Width
Accessories information available
on the web at frigidaire.com
15-1/4"
25-1/2"
Specifications
subject to change.

RAC Through-The-Wall Models
Frigidaire Baseline
Home Comfort
FRA144HT2 Through-The-Wall Air Conditioner
Home Comfort Specifications
•
Product Shipping Weight (approx.) – 93 Lbs.
•
Single phase 3-wire cable, 240 / 208 Volt, 60 Hertz AC only electrical
supply with ground required on separate circuit fused on both sides
of line.
•
Amps @ 240 / 208 Volts = 7.4 / 8.4 Amps
•
Recommended Circuit Breaker – 15 Amps
•
Unit equipped with 240 / 208V 3-wire power supply cord, NEMA plug
type 6-15P, approximately 72" long.
•
Unit’s increased performance characteristics result from two rear
intakes. For unit to operate at maximum efficiency, carefully follow
complete, detailed new or replacement installation instructions
provided in Product Installation Guide on web.
•
Unit requires rearward slope when installation is complete, to allow
condensate to drain from rear of sleeve.
New Installation
•
For new installation, Frigidaire® Through-The-Wall 18" Sleeve Kit
PN # EA108T available. Recommended for proper installation.
•
Through-the-wall installation requires 18" maximum wall thickness.
•
For energy-saving purposes, install unit in shady location, preferably
a northern exposure; and do not block airflow inside with blinds,
curtains or furniture; or outside with shrubs, enclosures or other
buildings.
•
USA
10200 David Taylor Drive
•
CANADA
FRA144HT2 04/11 © 2011 Electrolux Home Products, Inc. Printed in the U.S.A.
5855 Terry Fox Way
•
Charlotte, NC 28262
•
Mississauga, ON L5V 3E4
•
1-800-FRIGIDAIRE
•
1-800-265-8352
•
frigidaire.com
•
frigidaire.ca
Replacement Installation
•
When replacing existing air conditioner with new unit, refer to
Product Installation Guide on web to identify existing wall-sleeve
manufacturer and size compatibility. If proper installation and slope
are suspect, then correct installation of Frigidaire® Through-The-Wall
18" Sleeve Kit PN # EA108T recommended.
•
Use of existing wall sleeve to mount new unit requires original sleeve
be in sound structural condition with rear grille that attaches securely,
or rear flange that serves as stop for unit.
•
Preferable installation option, for increased efficiency and possibility
of drafts reduced, requires existing rear grille (mounted to sleeve) be
replaced with new unit’s rear air-directional louvered grille (provided
in accessory kit, shipped with unit). Non-preferable installation option
of directly mounting rear louvered grille to unit can be considered,
requiring grille be mounted to unit prior to sleeve installation.
•
Existing decorative exterior grille may be left in place, provided that
proper air-directional rear louvered grille is installed.
•
For installation into larger existing sleeve, optional Trim Kit
PN # EA120T available.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Through-The-Wall 18" Sleeve Kit – (PN # EA108T).
•
Trim Kit (for larger existing sleeve) – (PN # EA120T).
•
Architectural-Style Exterior Louvered Grille – (PN # EA109T).
Specifications
subject to change.