FRIGIDAIRE
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii__
:Kagil i
i_1iiiii!iHiiiii11i1_11iii_iiti1_fi_i]i1iiiiiiiijiiijIiii_ii_iiiiiii1iiiiiiiiiii_ii]iiiiii_ii1iiii_iiiiii1_iii_
www,frigi
This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
The power supply cord with
this air conditioner contains a current
detection device designed to reduce the risk
of fire.
U
Please refer to the section 'Operation of
Current Device' for details.
In the event that the power supply cord is
damaged, it cannot be repaired, tt must be
replaced with a cord from the product To reduce the risk of fire, electrical shock, or injury to persons when using your air conditionel
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.
For Your Safety
Prevent Accidents
manufacturer, followbasicprecautions,includingthefollowing:
° Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.
• If the air conditioner is to be installed in a window, you will probably want to clean both
Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.
iiii ii
sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation.
• Be sure the air conditioner has been securely and correctly installed according to the
separate installation instructions provided with this manual. Save this manual and the
installation instructions for possible future use in removing or reinstalling this unit.
• When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
and rear coils.
DANGER.I Avoid Serious Injury or Death
This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
Do not insert or place fingers or objects into the air discharge area in the front of the unit.
Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.
Do not cut or damage the power cord.
If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized
Electrolux servicer.
• Do not operate the air conditioner with wet hands.
• Do not pull on the power cord.
• Do not drink any water that is drained from the air conditioner.
02009 Electrolux Home Products, Inc. All rights reserved.
CAUTION. I Avoid Injury or damage to the unit or other property
o
Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make
units run excessively.
o
Do not climb on or place objects on outdoor part of the unit.
Do not hang objects off the unit.
Do not place containers with liquids on the unit.
Turn off the air conditioner at the power source when it will not be used for an extended period of time.
Periodically check the condition of the unit's installation accessories for any damage.
Do not apply heavy pressure to the radiator fins of the unit.
Operate the unit with air filter in place.
Do not block or cover the intake grille, discharge area and outlet ports.
Ensure that any electrical/electronic equipment is one yard away from the unit.
Do not use or store flammable gases near the unit.
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.
Unit must be upright for one hour prior to operating.
Operation of Current
Device
Plug in & _,
press RESET
The power supply cord contains a current device that senses damage to the power cord. To test
your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will
notice a click as the RESETbutton pops out.
3. Press the RESET button, Again you will notice a click as the button engages,
4. The power supply cord is now supplying electricity to the unit,
, Do not use this device to turn the unit on or off.
• Always make sure the RESET button is pushed in for correct operation.
, The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,
or it cannot be reset. A new one can be obtained from the product manufacturer.
• If power supply cord is damaged, it CANNOT be repaired, It MUST be replaced by one obtained
from the product manufacturer.
02009 Electrolux Home Products, Inc. All rights reserved.