Frigidaire E30IC80ISS1, E30IC80QSS0, E36IC80ISS1, E36IC80QSS0, EW30IC60IB1 Installation Guide

...
UnitedStates
IMPORTANT INSTALLATION INFORMATION
electrical supply with ground.
= Minimum distance between cooktop and overhead cabinetry is 30" (76.2 cm).
INSTALLATION AND SERVICE MUST BE PERFORMED BY A
QUALiFiED iNSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
30" (76.2 cm) min. for unprotected cabinet and 24" (61 cm) min. for cabinet with protected
bottom surface,
** DO NOT obstruct these
areas.
Cooktop Dimensions
Cooktop Cutout Dimensions
30" Min. * (76.2 cm)
D
H
DO NOT apply any sealant along the perimeter. The cooktop must breath freely,
C
F
4" X 8" (10.2 cm x 20.3 cm)
opening to route armored cable
_/::::::::¢:: if a panel is present
i [_-....... :.,i
Figure 1
i_i_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_i_iii_i_i_i_i_i_i!i!i_i!!!i_iiiiiiiiiiiii_@_i__iii_'!@@i_ii_i_@ii_!ii!ii!iiii_ili!
21_/p(54,6) 3(7,6) 43/8(11,1) 21_/p(54,6) 3(7,6) 43/8(11,1)
All dimensions are stated in inches and (cm). Allow 2" (5 cm) space below the armored cable opening to clear the electric cable and allow space for installation of the junction box on the wall at the back of the cooktop.
Printed in Canada
287/8(73,3)
35_(89.5)
20 (50,8) 20 (50,8)
29% (75,2) 357/8(91,1)
29:_(75,6)
36(91.4)
20%(51,8) 20sh(51,8)
P/N 318205412 (1202) Rev. D
English - pages 1-8
Espafiol - paginas 9-16
Frangais - pages 17-24
Overhead Cabinet Should Not Exceed a
Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min. Cle ui Between the Top of the
Cooking Platform and the Bottom of an Unprotected
Wood or Metal Cabinet _A
1
24" (61 cm) Min. when Bottom of Wood or Metal Cabinet
is Protected by Not Less Than 1/8" (o.g cm) Flame
Netardant Millboard Covered With Not Less Than No. 28
MGS Sheet Steel, 0.015" (0.4 mm) Stainless Steel, 0.024"
(0.6 ram) Aluminum or 0.020" (0.5 mm) Copper.
"_ Nearest Combustible 10"
18" G
(45.7 cm)
...............I
Edge of Cutout and
Surface Above 25.4 cm) Countertop
J Min. From Edge of
_.Cooktop to Nearest
Combustible Wall (Either Side of Unit).
2Y2"(6.4 cm) Min. From
* Letters on this figure refer to chart
on front page except for J and K.
Edge of Cutout to Front Edge of Countertop
Figure 2 - COUNTERTOP CUTOUT OPENING
To eliminate the risk of burns
or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet
storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
Model and Serial Number Location
The serial plate is located under the cooktop. When ordering parts for or making inquires about
your cooktop, always be sure to include the model and serial numbers and a lot number or letter from the
serial plate on your cooktop.
Apl Junction Box
i
30" 36"
Serial plate is located under the burner box
of cooktop.
Location of
2" (5.1 cm) 2" (5.1 cm)
It is not recommended to use drawer underneath cooktop.
Empty space is needed for installation purpose.
J i ! !! ii !i ii i! ii i i !i!i i i iiiii i ii i! iiiiii ii i! i iiiii! ii!i iiiii ii!ii iiiiiiiiii!iiii i ii !i !! i iiii ii !! !!!i!!ii ii iiiiiiiiiiiiiiiiii i !ii ii!i i!!! i i!! !i!i !!i i! i! i! i i !ii ii ii ii
1 1/2" (3.8cm)
2" (5.1cm)
2
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing the cooktop.
2. Remove all packing material before connecting the electrical supply to the cooktop.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Only certain cooktop models may be installed over certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFG ID number and product code.
Important Note to the Consumer
Keep these instructions with your Use and Care Guide for future reference.
An extension cord must not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury.
3. The appliance should be connected to the fused
disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable.
The flexible armored cable extending from this appliance should be connected directly to the grounded junction box. The junction box should be located as shown in Figure 2 with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.
4. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
I PO NT SAFETY
IoSTR CTI
Be sure your cooktop is installed and grounded properly by a qualified installer or service
technician.
This cooktop must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.
70--latest edition in the United States.
The electrical power to the cooktop
must be shut off while line connections are being made. Failure to do so could result in serious
injury or death.
Provide Electrical Connection
Install the junction box under the cabinet and run 120/240 or 120/208 Volt, AC wire from the main circuit panel. NOTE: DO NOT connect the wire to the circuit panel at this time.
Electrical Requirements
Observe all governing codes and local ordinances.
1. A 3-wire or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (time-delay fuse or circuit breaker is recommended). DO NOT fuse neutral.
2. A circuit breaker or fuse rated at 50 Amp is recommended (40 Amp minimum).
NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance
with the National Electrical Code ANSI/NFPA No. 70-latest edition and local codes and ordinances.
Unpacking Instructions
1. Unpack and visually inspect the cooktop.
2. Be sure the bottle of cleaner conditioner packed in the literature bag is left where the user can find it easily. It is important that the ceramic-glass cooktop be pretreated before use. See Cooktop Cleaning and Maintenance section in the Use
and Care Guide,
Electrical Connection
Connect the flexible armored cable that extends from the surface unit to the junction box using a suitable
strain relief at the point the armored cable enters the junction box. Then make the electrical connection as
follows. Electrical ground is required on this appliance.
This appliance is equipped with a
copper conductor flexible cable. If connection is made to aluminum house wiring, use only
special connectors which are approved for joining copper and aluminum wires in accordance with
the National Electrical Code and local codes and ordinances. Improper connection of aluminum
house wiring to copper leads can result in a short circuit or fire. Follow the connector manufacturer
recommended procedure closely.
This appliance is manufactured with a supply wire and a frame connected green or bare copper grounding
wire.
DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.
3
if the cable from agpliance is e_ed with 3 wires:
Where local codes permit connecting the appliance-grounding conductor to the neutral (white) wire (see figure 3):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box, connect appliance and power supply cable wires as shown in figure 3.
You may not ground the cooktop
through the neutral (white) wire if cooktop is used
in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local
codes do not permit grounding to the neutral (white) wire.
Cable from Power Supply
White Wire
(Neutral),,
Wires __ Black
Wires
Box
U.L.-Listed
Green Wire (Ground)
Conduit Connector
Cable from
appliance
Figure 3 =3=WIRE GROUNDED JUNCTION BOX
When grounding to the neutral (white) wire is
prohibited, you must use a 4-wire power supply
cable. See Figure 4. Failure to heed this warning
may result in electrocution or other serious personal injury,
if cooktop is used in a new branch circuit
installation (1996 NEe), mobile home, recreational vehicle, or where local codes DO NOT permit grounding to the neutral (white) wire (see figure 4):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box,
connect appliance and power supply cable wires as shown in figure 4.
Cable from Power Supply
"_..__._ r White Wire
Ground Wire[_ ,.........[',,_-_--_
Red :!::::
Wire res
ion
..................IL ,
Green Wire (Gr°u-__'-nListted__v_ v_ Conduit
Cable from appliance
Figure 4 - 4-WIRE GROUNDED JUNCTION BOX
If connecting to a 4-wire power supply
cable electrical system, the appliance frame connected ground wire MUST NOT be connected to
the neutral wire of the 4-wire electrical system.
NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL-listed for connection
to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor wire is governed by the temperature rating of the insulation around the wire,
rather than the wire gauge alone.
4
if the cable from ap_pliance is equipped with 4 wires:
Where local codes permit connecting the appliance=grounding conductor (wire) to the neutral (white) wire (see figure 5):
.
Disconnect the power supply.
2.
In the circuit breaker, fuse box or junction box,
connect appliance and power supply cable wires as shown in figure 5.
Cable from Power Supply
White Wire _--_,,__,
(Neutra))r ?- :-_-ii
Wires
Black
ires -
f_----- ,Junction
"t-.
........11 _ "White Wire
Ground Wire J (Bare or Green Wire)
Cable from appliance
Figure 5
3-WIRE GROUNDED JUNCTION BOX
This appliance is manufactured with a white neutral power supply and a frame connected copper wire, The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit, if used in USA, in a new branch circuit installation (1996 NEC), mobile home, recreational vehicles, where local code do not permit grounding trough the neutral (white)
wire or in Canada, disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes,
connect neutral lead to branch circuit-neutral conductor in usual manner see Figure 6. if your
appliance is to be connected to a 3 wire grounded junction box (US only), where local code permit connecting the appliance=grounding conductor to the neutral (white) see Figure 5,
"" (Neutral)
U.L.-Listed Conduit Connector (or CSA listed)
if cooktop is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire (see
figure 6):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white appliance cable wires.
3. In the circuit breaker, fuse box or junction box: connect appliance and power supply cable wires as shown in figure 6.
Cable from Power Supply Ground Wire
Wires]
-- Black
Ground Wire (Bare or
Green Wire)
Conduit
Junction Box (or CSA listed)
Cable from appliance
Figure 6
4=WIRE GROUNDED JUNCTION BOX
if connecting to a 4=wire power supply cable electrical system, the appliance frame connected ground wire MUST NOT be
connected to the neutral wire of the 4=wire electrical system.
NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance are UL and
CSA-recognized for connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating
of the insulation around the wire, rather than the wire gauge alone.
5
Cooktop Installation
1. Visually inspect the cooktop for damage. Also make sure all cooktop screws are tight (see Figure 7).
Screws
Figure 7
2. Install the retainer brackets. See Figure 8.
The retainer brackets MUST be installed, to meet local codes or, in their absence, with the National
Electrical Code ANSI/NFPA No. 70--latest edition
(see Figure 8).
Do not remove the spring spacers on
the edges of the cooktop. These spacers center the
cooktop in the space provided. The cooktop must be centered to prevent excess heat buildup that
may result in heat damage or fire (see Figure 9).
4. Fix the cooktop to the bracket using the screws supplied (see Figure 9).
Hole located under the Spring burner box to Spacer (8)
fix the retainer bracket.
Position brackets on unit cutout center line as shown.
Figure 9
,
Set the cooktop into the countertop cutout.
Cooktop Countertop
Spacer
Retainer Bracket
Figure 8
NOTE: Do not use caulking compound; cooktop should be removable for service when needed.
Checking Operation
Refer to the Use and Care Guide for operation.
Do not touch cooktop glass or elements.
They may be hot enough to burn you.
Before You Call for Service
Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide.
It may save you time and expense. The list includes common occurrences that are not the result of
defective workmanship or materials in this appliance. Refer to your Use and Care Guide for service phone
numbers.
6
Fortypicalundercounterinstallationofanelectricbuilt-inovenseeFigurebelow.
Onlycertaincooktopmodelsmaybeinstalled overcertainbuilt-inelectricovenmodels.
Approvedcooktopsandbuilt-inovensare
listedbytheMFGIDnumberandproductcode
(seetheinsertsheetincludedintheliterature
packageandcooktopinstallationinstructions
fordimensions).
To reduce the risk of personal injury and
tipping of the wall
oven, the wall oven must be secured to
the cabinet (s) by
mounting brackets.
208/240 Volt junction box
for built-in
Approx. 3"
(7.5 cm)
Approx. 3"
Note 1
(7.5 cm)
Note 1: 4" x 4" (10.2 X 10.2 cm) opening to route armoured cable from cooktop to junction
box.
208/240Volt junction box
for Cooktop
Cabinet side filler
panels are necessary
to isolate the unit from adjoining cabinets.
Cabinet side filler
height should allow for installation of approved
cooktop models
36" Min. (91.4 cm) Min.
Cut an opening in wood base minimum 4" x 4" (10.2 X 10.2 cm), 2" (5 cm) from left side filler
panel, to route armoured cable to junction box.
If no cooktop is installed directly over the oven unit, 5" (12.7 cm)
maximum is allowed above the floor.
CUTOUT DIMENSIONS
. F.WIDTH J G. DEPTH. H. HEIGHT
27" (68.6 cm) 247/s' (63.2 cm) Min. 231/2' (59.7 cm) Min. 27_¼' (69.2 cm) Min.
Wall Oven 25_¼' (64.1 cm) Max. 281¼' (71.8 cm) Max.
30" (76.2 cm) 281/2' (72.4 cm) Min. 231/2' (59.7 cm) Min. 27_¼' (69.2 cm) Min.
Wall Oven 29" (73.7 cm) Max. 281¼' (71.8 cm) Max.
Unit will overlap
(minimum) edges by 1" (2.5cm)
3/4" 1.9 cm)
plywood, installed on
two runners, flush with toe plate. Base must be
capable of supporting 150
pounds (68 kg) for 27" models and 200 pounds
(90 kg) for 30" models.
4Y2"(11.5cm)
Max.*
Figure 10- TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN
WITH AN ELECTRIC COOKTOP MOUNTED ABOVE
7
8
Loading...
+ 16 hidden pages