Frigidaire FMV157G, FMV157GB - 1.5 cu. Ft. Microwave Oven, FMV157GQ - 1.5 cu. Ft. Microwave Oven, FMV157GS - Microwave Installation Instructions Manual

7
Installation Over the Range Instructions Microwave Oven
Questions? Call
1-800-944-9044(US) 1-800-668-4606(Canada)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
instructions for local inspector’s use.
governing codes and ordinances.
Note to Installer –
instructions with the Consumer.
Save these
Observe all
Be sure to leave these
or Visit our Website at:
Note to Consumer – Keep these
instructions for future reference.
Skill level – Installation of this appliance requires basic mechanical and electrical skills.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not
covered under the Warranty.
http://www.frigidaire.com
READ CAREFULLY.
KEEP THESE INSTRUCTIONS
.
2
Recirculating ........................................ 19–22
Attach Mounting Plate to Wall............19
Preparation of Top Cabinet ................19
Check Microwave Assembly ................20
Adapting Microwave Blower
for Recirculation ..........................20, 21
Mount the Microwave Oven ..........21, 22
Installing the Charcoal Filter ..............22
Before You Use Your Microwave .......................... 23
CONTENTS
General information
Important Safety Instructions .................................. 3
Electrical Requirements .......................................... 3
Hood Exhaust ...................................................... 4, 5
Damage – Shipment/Installation.............................. 6
Parts Included.......................................................... 6
Tools You Will Need ................................................ 7
Mounting Space ...................................................... 7
Step-by-step installation guide
Placement of Mounting Plate ............................ 8–10
Removing the Mounting Plate ...................... 8
Finding the Wall Studs.................................. 8
Determining Wall Plate Location.................. 9
Aligning the Wall Plate................................ 10
Installation Types.............................................. 11–22
Outside Top Exhaust ............................ 12–14
Attach Mounting Plate to Wall ............12
Preparation of Top Cabinet ................13
Checking for Proper Damper
Operation............................................13
Mount the Microwave Oven ..........13, 14
Adjust the Exhaust Adaptor ................14
Connecting Ductwork..........................14
Outside Back Exhaust............................ 15–18
Preparing Rear Wall for
Outside Back Exhaust..........................15
Remove Exhaust Adaptor ......................15
Attach Mounting Plate to Wall ............16
Preparation of Top Cabinet ................16
Adapting Microwave Blower
for Outside Back Exhaust................16, 17
Mount the Microwave Oven ................18
A
B
C
Installation Instructions
This product requires a three-prong grounded outlet. The installer must perform a ground continuity check on the power outlet box before beginning the installation to insure that the outlet box is properly grounded. If not properly grounded, or if the outlet box does not meet electrical requirements noted (under ELECTRICAL REQUIREMENTS), a qualified electrician should be employed to correct any deficiencies.
CAUTION: For personal safety, remove house fuse or open circuit breaker before beginning installation to avoid severe or fatal shock injury.
CAUTION: For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this 63–85 pound (28.5–38.5 kg) product, plus additional oven loads of up to 50 pounds (22.7 kg) or a total weight of 113–135 pounds (51.3–61.2 kg).
CAUTION: For personal safety, this product cannot be installed in cabinet arrangements such as an island or a peninsula. It must be mounted to BOTH a top cabinet AND a wall.
NOTE: For easier installation and personal safety, it is recommended that two people install this product.
IMPORTANT – PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.
The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance.
You should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is very important to have it replaced with a properly grounded three-prong wall receptacle, installed by a qualified electrician.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.
IMPORTANT SAFETY INSTRUCTIONS
3
ELECTRICAL REQUIREMENTS
Product rating is 120 volts AC, 60 Hertz, 15 amps and
1.6 kilowatts. This product must be connected to a supply circuit of the proper voltage and frequency. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug should be brought to a separate 15- to 20- ampere branch circuit single grounded outlet. The outlet box should be located in the cabinet above the microwave oven. The outlet box and supply circuit should be installed by a qualified electrician and conform to the National Electrical Code or the prevailing local code.
Ensure proper ground exists before use
Installation Instructions
4
EQUIVALENT NUMBER EQUIVALENT
DUCT PIECES LENGTH x USED = LENGTH
Roof Cap 24 Ft. (7.3 m) x (1) = 24 Ft. (7.3 m)
12 Ft. (3.6 m) Straight Duct 12 Ft. (3.6 m) x (1) = 12 Ft. (3.6 m) (6”/15.2 cm Round)
Rectangular-to-Round 5 Ft. (1.5 m) x (1) = 5 Ft. (1.5 m) Transition Adaptor*
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.
Total Length = 41 Ft. (12.5 m)
HOOD EXHAUST
The following chart describes an example of one possible ductwork installation.
NOTE: Read these next two pages only if you plan to vent your exhaust to the outside. If you plan to recirculate the air back into the room, proceed to page 6.
OUTSIDE TOP EXHAUST (EXAMPLE ONLY)
NOTE: For back exhaust, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper
will have to be cut to fit, using the tin snips, in order to allow free movement of the damper.
The following chart describes an example of one possible ductwork installation.
Installation Instructions
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
EQUIVALENT NUMBER EQUIVALENT
DUCT PIECES LENGTH* x USED = LENGTH
Wall Cap 40 Ft. (12.2 m) x (1) = 40 Ft. (12.2 m)
3 Ft. Straight Duct 3 Ft. (0.9 m) x (1) = 3 Ft. (0.9 m) (31⁄4” x 10”/8.2 x 25.4 cm Rectangular)
90° Elbow 10 Ft. (3 m) x (2) = 20 Ft. (3 m)
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.
Total Length = 63 Ft. (19.2 m)
EQUIVALENT NUMBER EQUIVALENT
DUCT PIECES LENGTH x USED = LENGTH
Rectangular-to-Round 5 Ft. (1.5 m) x ( ) = Ft. or m Transition Adaptor*
Wall Cap 40 Ft. (12.2 m) x ( ) = Ft. or m
90° Elbow 10 Ft. (3 m) x ( ) = Ft. or m
45° Elbow 5 Ft. (1.5 m) x ( ) = Ft. or m
90° Elbow 25 Ft. (7.6 m) x ( ) = Ft. or m
45° Elbow 5 Ft. (1.5 m) x ( ) = Ft. or m
Roof Cap 24 Ft. (7.3 m) x ( ) = Ft. or m
Straight Duct 6“ (15.2 cm) 1 Ft. (0.3 m) x ( ) = Ft. or m Round or 31⁄4“ x 10“ (8.2 x 25.4 cm) Rectangular
Total Ductwork = Ft. or m
Equivalent lengths of duct pieces are based on actual tests and reflect requirements for good venting performance with any vent hood.
* IMPORTANT: If a rectangular-to-round transition
adaptor is used, the bottom corners of the damper will have to be cut to fit, using the tin snips, in order to allow free movement of the damper
.
NOTE: If you need to install ducts, note that the total duct length of 3
1
4x 10(8.2 x 25.4 cm) rectangular or
6(15.2 cm) diameter round duct should not exceed
120 equivalent feet (36.5 m).
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
NOTE: It is important that venting be installed using the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps prevent blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
Exhaust connection:
The hood exhaust has been designed to mate with a standard 31⁄4x 10(8.2 x 25.4 cm) rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than
a 6(15.2 cm) diameter duct.
Maximum duct length:
For satisfactory air movement, the total duct length of 31⁄4x 10(8.2 x 25.4 cm) rectangular or 6(15.2 cm) diameter round duct should not exceed 120 equivalent
feet (36.5 m).
Elbows, transitions, wall and roof caps, etc.,
present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length using the approximate feet of equivalent length of some typical ducts.
5
Installation Instructions
PART
QUANTITY
Top Cabinet 1 Template
Rear Wall 1 Template
Installation 1 Instructions
Separately 2 Packed Grease Filters
PART QUANTITY
Wood Screws 2 (1⁄4“ x 2“)
Toggle Bolts (and 4 wing nuts) (3⁄16“ x 3“)
Self-Aligning Machine 3 Screws (1⁄4“-28 x 31⁄4“)
Nylon Grommet 2 (for metal cabinets)
Power Cord Strap 1 (plastic)
6
If the unit is damaged in shipment, return the
unit to the store in which it was bought for repair or replacement.
If the unit is damaged by the customer, repair or
replacement is the responsibility of the customer.
If the unit is damaged by the installer (if other
than the customer), repair or replacement must be made by arrangement between customer and installer.
DAMAGE—SHIPMENT/ INSTALLATION
PARTS INCLUDED
(CONT.)
INSTALLA
TION
INSTRUCTIONS
ADDITIONAL PARTS
TOP CABINET TEMPLATE
Installation Instructions
REAR
WALL
TEMPLATE
PARTS INCLUDED
You will find the installation hardware contained in a packet with the unit. Check to make sure you have all these parts.
NOTE: Some extra parts are included.
HARDWARE PACKET
7
TOOLS YOU WILL NEED
# 1 Phillips screwdriver
Pencil
Ruler or tape measure and straight edge
Carpenter square (optional)
Tin snips (for cutting damper, if required)
Electric drill with 3⁄16, 1⁄2and 5⁄8 drill bits
Hammer (optional)
Stud finder or
Filler blocks or scrap wood pieces, if needed for top cabinet spacing (used on recessed bottom cabinet installations only)
Gloves
Saw (saber, hole or keyhole)
Level
Duct and masking tape
MOUNTING SPACE
NOTES:
The space between the cabinets must be
30(76.2 cm)wide and free of obstructions.
If you are going to vent your microwave oven
to the outside, see Hood Exhaust Section for exhaust duct preparation.
When installing the microwave oven beneath
smooth, flat cabinets, be careful to follow the instructions on the top cabinet template for power cord clearance.
Backsplash
66(167.6 cm) or More from the Floor to the Top of the Microwave
30
(76.2 cm)
2
“ (5.1 cm)
30
(76.2 cm)
min.
16
1
2“ (41.9 cm)
Bottom Edge of
Cabinet Needs to
be 30(76.2 cm)
or More from the
Cooking Surface
Installation Instructions
Scissors (to cut template, if necessary)
Safety goggles
8
Find the studs, using one of the following methods:
A. Stud finder – a magnetic device which
locates nails.
OR
B. Use a hammer to tap lightly across the
mounting surface to find a solid sound. This will indicate a stud location.
After locating the stud(s), find the center by probing the wall with a small nail to find the edges of the stud. Then place a mark halfway between the edges. The center of any adjacent studs should be 16(40.6 cm) or 24(61 cm) from this mark.
Draw a line down the center of the studs.
THE MICROWAVE MUST BE CONNECTED TO AT LEAST ONE WALL STUD.
1
Remove the installation instructions, filters, glass tray and the small hardware bag. Do not remove the Styrofoam protecting the front of the oven.
Fold back all 4 carton flaps fully against carton sides. Then carefully roll the oven and carton over onto the top side. The oven should be resting in the Styrofoam.
REMOVING THE MICROWAVE OVEN FROM THE CARTON/ REMOVING THE MOUNTING PLATE
FINDING THE WALL STUDS
B
.
A
.
2
PLACEMENT OF THE MOUNTING PLATE
1
Wall Studs
Center
3
Carton
Pull the carton up and off the oven.
Remove the screws from the mounting plate. This plate will be used as the rear wall template and for mounting. Reinstall the screws into the holes where they were removed.
Mounting Plate
Screws
2
Styrofoam
Installation Instructions
3
5
Remove and properly discard plastic bags.
4
1
Loading...
+ 16 hidden pages