Frigidaire FMV156DBA, FMV156DCA, FMV156DQA, FMV156DSA Installation Guide

m m
BEFORE YOU 8EGmN Roadthe.o,',.,r,,c.o,,.com ,tetely.r,dcoror,,.y.
® _IPOR'rANT- Save these instructions for
local inspector's use.
® _MPOR"rANT- Observe all governing codes
and coordinates.
. Note to installer- Be suretoleave these
instructions with the Consumer.
tions for future reference.
. Skitl LeveJ - Installation of this appliance
requires basic mechanical and electrical skills.
UNPACKING AND EXAMINING
YOUR OVEN
Open the bottom of the carton, bend the carton flaps back and tilt the oven over to rest on plastic foam pad. Lift carton off oven
and remove all packing materials, WALL and TOP CABINET TEMPLATE, Turntable, and Turntable Support. SAVE THE CARTON AS IT MAY MAKE INSTALLATION EASIER.
1.Remove the feature sticker from the outside of the door, if there is one.
2. DO NOT REMOVE THE WAVEGUIDE COVER, which is located on the right side wall of the oven cavity. Check to
see that there is a Wall TEMPLATE and Top CABINET Template. Read enclosures and SAVE the Operation
Manual.
Check the oven for any damage, such as misaligned or bent door, damaged door seals and sealing surfaces, broken or
loose door hinges and Iatches and dents inside the cavity or on the door. If there is any damage, do not operate the oven and contact your dealer or ELECTROLUX AUTHORIZED SER-
VICER. See installation instructions for more details.
Proper installation is the responsibility of the instailer. Product failure due to improper installation is not cov-
ered under the Warranty.
Please read atI instructions thoroughly before installing the Over the Range Microwave Oven. Two people are recommended to install this product.
If a new electrical outlet is required, its installation should be completed by a qualified electrician before
the Microwave Oven is installed. See 3 ELECTRICAL GROUNDING INSTRUCTIONS on page 2.
Hinges
OvenCavity
Safetydoor Doorseals and latches sealingsurfaces
NEED HELP?
For customers in the United States, call: 1-800-944-9044 For customers in Canada, caII: 1-800-213-9397 (Engiish)
1-800-668-4606 ext.8199 (French) READ CAREFULLY, KEEP THESE INSTRUCTIONS,
P/N316137336
TINSEB386MRR0
mnsta ation
1 MOUNTING SPACE
This Microwave Oven/Hood requires a mounting space on a wall as shown in Figure 1. It is designed to be used with stan-
dard 12-inch wail cabinets.
If the space between the wall cabinets is 36 or 42 inches, a Filler Panel Kit can be used to fill the gap. The meta! filler pan- els come in 3-inch wide pairs. One set is needed for a 36-inch opening and 2 sets for a 42-inch opening. The Filler Panel Kit
should be installed before the Microwave Oven/Hood is installed.
H iliiiii i i!iliiiiiiiil
_ IIf:!S!;i_,ilillillillillillillillillillillillillillillillilli_
30" or morefrom
BacksplashAt least2"
=
Figure I
2 WALL CONSTRUCTION
This Microwave Oven/Hood should be mounted against and supported by a flat vertical wall. The wall must be flat for prop-
er installation. If the wall is not flat, use spacers to fill in the gaps. Wall construction should be a minimum of 2" x 4" wood studding and 3/8" or more thick dry wall or piaster/lath. The mounting surfaces must be capable of supporting a weight of
110 poundslthe oven and contents--AND the weight of all items which would normally be stored in the top cabinet above
the unit. The unit shoumd be attached to a minimum of one 2" x 4"
wall stud or two 2" x 3"' wall studs. To find the location of the studs, one of the following methods
may be used: A.Use a stud finder, a magnetic device which locates the nails
in the stud.
B.Use a hammer to tap lightly across the mounting surface to
find a solid sound. This will indicate stud location.
The center of the stud can be !ocated by probing the wall with a small nail to find the edges of the stud and then placing a mark halfway between the edges. The center of any adjacent studs
will normally be 16" or 24" to either side of this mark.
J cookingsurface
66"or more
J fromfloor
3 ELECTRICAL GROUNDmNG
This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a grounding plug. It must be plugged into a wail receptacle that is properly installed and
grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short
circuit, grounding reduces risk of electric shock by providing an escape wire for the electric current.
WARNING - Improper use of the grounding plug can result in a risk of electric shock,
The oven is equipped with a 3-prong - _;_
ANY CIRCUMSTANCES CUT OR G,o_0diogp,_ grounding plug. DO NOT UNDER /...-r_
REMOVE THE GROUNDING PiN 3-ProngReceptacle / FROM THE PLUG, Roc_p_loBo*
The Power Supply Cord and plug must be connected to a sep- arate 120 Volt AC, 60 Hz, 15 Amp, or more branch circuit, sin- gle grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven mounting
location as shown in Figure 2. NOTE:
1.If you have any questions about the grounding or electrical instructions, consult a qualified electrician or serviceperson.
2.Neither ElectroIux nor the dealer can accept any liability for damage to the oven or personal iniury resulting from failure to
observe the correct electrical connection procedures.
RADIO OR TV _NTERFERENOE Should there be any interference caused by the microwave
oven to your radio or TV, check that the microwave oven is on a different electrical circuit, relocate the radio or TV as far away from the oven as feasible or check position and signal of receiv- ing antenna.
Ground Receptacle
Openingfor
PowerCord
Figure 2
3-Prong Plug
Ground
mnsta ation
4 HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust duct is required. AII ductwork must be metaI; absolutely do not use
pIastic duct. Check that all connections are made securely. Please read the foilowing carefully:
Exhaust sonneetiom The hood exhaust has been designed to connect to a standard 3-1/4" X 10" rectangular duct. If round duct is required, a rectanguIar-to-round adapter must be used.
Rear exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the space between the
studs, or waII should be prepared at the time it is constructed by leaving enough space between wall studs to accommodate exhaust.
Maximum duet length: For satisfactory air movement, the total duct length of 3-1/4" X 10" rectangular or 6" diameter round duct
should not exceed 140 feet. Elbows, adapters, walI caps, roof caps, etc. present additional
resistance to air flow and are equivalent to a section of straight duct which is Ionger than their actual physical size. When caIcu-
lating the total length, add the equivalent lengths of all transi- tions and adapters plus the length of all straight duct sections. Figure 3 shows the approximate feet of equivalent length of some typical ductwork parts. Use the values in parentheses for calculating air flow resistance equivalent, which should totaI
less than 140 feet.
90° ELBOW (10 FT,)
90° ELBOW (25 FT.)
45_ ELBOW (5 FT,)
45° ELBOW (5 FT.)
ADAPTOR (5 FT,)
WALL CAP (40 FT.)
10"WIDE ELBOW (t0 FT,)
ROOF CAP (24 FT.)
5 TOOLS RECOMMENDED FOR
Phillips Screwdriver Protective Drop Cloth for Electric Drill product and range -
1/2", 5/8" and 3/32" Drill for protection Bits
1-1/2" Wood Bit or Metal Hole Cutter Pencil
(if metal cabinet is used) Measure
Saw to cut exhaust Tape opening (if needed)
you may also use carton
Scissors
6 INSTALLATION HARDWARE
The INSTALLATION HARDWARE items (_ - _) are packed in a small bag. Items _- @ are packed separately. AII items are in a small carton packed below the oven.
_tem Name Quantity ___ WoodScrew5X 30 mm 6
ToggleB01twithnuts 4
(_) SopCabinetScrew5 X60mm 2
PowerCord Hanger 1 TappingScrew4 x 12mm 3
FlatWasher30mm diameter 2 Grommet 1
RearCushion 1 ExhaustDamperAssembly 1
ScalePlate 2 GreaseFilter 2
Figure 3
_'_U_e with metal cabinets. Surround
®
@ _he power cord opening. Cut to fit.
® @ @
!o IIIItt
Figure 4
Parts shown not to common scale.
Loading...
+ 5 hidden pages