![](/html/51/51f8/51f830d09157849bccfec474536a4adb6cf87415f8dd13c1c0dfe34867c899b2/bg1.png)
INSTALLATIONANDSERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
This conversion kit must be installed by a qualified service technician in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. Failure
to follow instructions may result in fire, explosion or production of carbon monoxide causing property damage,
personal injury or loss of life. The qualified service agency is responsible for the proper installation ofthis kit. The
installation is not proper and complete until the operation ofthe converted appliance is checked as specified in the
manufacturer's instructions supplied with this kit.
Before proceeding with the conversion, shut offthe gas supply before disconnecting electrical power
to the range. Be sure both power supplies are off before installing the conversion kit. Failure to do so could cause
serious bodily injury.
Determine the combination of top burners that are featured on your range. Then identify the parts you need from
this kit to complete the LP. conversion. When burners are converted from Natural to LP the BTU rating is as follows:
5,000 BTU* Natural gas to 4,500 BTU* LP Gas 9,500 BTU* Natural Gas to 8,000 BTU* LP Gas
12,000 BTU* Natural Gas to 10,000 BTU* LP Gas 14,000 BTU* Natural Gas to 11,000 BTU* LP Gas
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
Part Number
316037526
316248105
316005215
316005216
316005217
316005218
316005219
316005220
316005221
316005222
316241200
316237904
316237905
316237906
316237907
Part Description
L.P. Conversion Kit Label
Instructions for converting range to LP Gas
Rating Plate - English
Rating Plate - English
Rating Plate - English
Rating Plate - English
Rating Plate - French
Rating Plate - French
Rating Plate - French
Rating Plate - French
L.P. Conversion Label
Orifice - 11,000 BTU*
Orifice- 10,000 BTU*
Orifice - 8,000 BTU*
Orifice - 4,500 BTU*
Notes
English and French
English, French and Spanish
4 - 8K
3+1
2+1+1
1+1+1+1
4 - 8K
3+1
2+1+1
1+1+1+1
English, French and Spanish
RED
GREEN
NO COLOR
BLUE
*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000
ft. above sea level.
IM PORTANT: After replacing the natural gas to LP orifices; be sure to keep the original factory installed natural gas
orifices for future range conversion back to natura! gas. The factory orifices are marked with 101 for 5,000 BTU; 154
for 9,500 BTU; 175 for 12,000 BTU and 193 for 14,000 BTU.
Tools Required for L.P. Conversion:
3/8", 1/2" and 5/8" Open End Wrench
1/8" Wide Flat Blade Screwdriver
7mm Nutdriver
PIN 316248105 (0104)
Frangais - Pages 6-10
Espa5ol - Paginas 11-15
![](/html/51/51f8/51f830d09157849bccfec474536a4adb6cf87415f8dd13c1c0dfe34867c899b2/bg2.png)
How to Convert the Range for use with LP/
Propane Gas
1. Convert the Pressure Regulator
To access the gas regulator, remove the storage drawer or warmer
drawer. If equipped with a storage drawer, open and remove the drawer
completely. For models equipped with a storage drawer or front panel,
remove the storage or front panel and skip steps a & b below. For models
equipped with warmer drawer, follow all the instructions below to remove
the warmer drawer.
a. _!_ Electrical Shock Hazard can occur and result in
serious injury or death. Disconnect electrical power to the range
before removing the warmer drawer for servicing.
b. Locate glide lever on each side of drawer, pull up on the left glide lever
and push down on the right glide lever (See Figure 1).
c. Pull the drawer away from the range (See Figure 2).
d. Remove the regulator access cover if equipped. Do not remove the
Pressure Regulator or allow it to turn.
e. Remove the dust protector from the cap. Using a 5/8" wrench,
unscrew the cap from the pressure regulator. Do not remove the
spring from the regulator.
f. Turn the cap over so the hollow end faces outward. Place the solid
end of the cap into the loop end of the dust protector (See Figure 3).
g. Replace the cap on the regulator. The letters LP should be visible on
the exposed end of the cap. Snap the dust protector over the
regulator cap.
Pull up with finger
Pressure
Front access to Regulator: Regulator
Open storage or warmer drawer, located at
or remove lower panel rear of
(on some models)
FIGURE 2
Dust
Protector
Spring
Left Glide
Push down with finger
FIGURE 1
Hollow End Solid End
Towards Towards
Regulator Regulator
FIGURE 3
Natural Gas Orifice to LP Orifice Conversion for each type of burner
5,000 BTU Natural Gas
converts to 4,500 BTU LP Gas
Install(blue)orifice68mm for LP 9,500BTU NaturalGas
for Natural Gas for LP/Propane Gas
converts to 8,000BTU LP Gas
Install orifice (nocoIor) ,89mmfor LP
14,000 BTU Natural Gas 12,000 BTU Natural Gas
converts to 11,000 BTU LP Gas converts to 10,000 BTU LP Gas
Install (red) orifice !.01mm for LP Install (green) orifice .95mm for LP
FIGURE 4