30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY:  Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
 Do not try to light any appliance. Do not touch any electrical switch; do not use any phone
in your building.
 Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
 If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
· ALL RANGES CAN TIP.
· INJURY TO PERSONS COULD RESULT.
· INSTALL ANTI-TIP DEVICE PACKED WITH RANGE.
· SEE INSTALLATION INSTRUCTIONS.
Clearances and Dimensions
1. LocationCheck location where the range will be installed. Check for proper electrical and gas supply, and the stability of the floor.
2. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be solid and level.
P/N 316105822 (0001)
Provide Proper Fuel Type
Before Proceeding: Your range is preset to operate on natural gas only. Some models are shipped convertible with parts and conversion instructions supplied. Other models have a LP/Propane Conversion Kit available through your dealer.
For models equipped with 4-9,000 BTU surface burners order kit #80-8802-10. For models equipped with 2-9,000 BTU and 2-11,000 BTU surface burners order kit 80-8904-10. For models equipped with 3-9,000 BTU and 1-11,000 BTU surface burners order kit #80-8809-10.
DO NOT attempt to convert this range to LP/Propane settings
without the proper LP/Propane conversion kit provided with the range or obtained from your dealer. Follow all instructions provided with the conversion kit.
Français - Pages 9-16
1
Español - Páginas 17-24
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
Important Notes to the Installer
1. Read all instructions contained in these installation instructions before installing range.
2. Remove all packing material from the oven compartments before connecting the gas and electrical supply to the range.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
Important Note to the Consumer
1. Keep these instructions with your owner's guide for future reference.
IMPORTANT SAFETY INSTRUCTIONS
Installation of this range must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1latest edition when installed in the United States. When installed in Canada, installation must conform with CAN/CGA-B149.1 and CAN/CGA-B149.2.
This range has been design certified by CSA International. As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will find them in the Owner's Guide, read it carefully.
Be sure your range is installed and grounded properly
by a qualified installer or service technician.
This range must be electrically grounded in
accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.70latest edition when installed in the United States. When installed in Canada, this range must be
electrically grounded in accordance with CSA Standard C22.1, Canadian Electrical Code, Part 1. See Grounding Instructions on page 5.
Before installing the range in an area covered with
linoleum or any other synthetic floor covering, make sure the floor covering can withstand heat at least 90°F above room temperature without shrinking, warping or discoloring. Do not install the
range over carpeting unless you place an insulating pad or sheet of 1/4-inch thick plywood between the range and carpeting.
Make sure the wall coverings around the range can
withstand the heat generated by the range.
Do not obstruct the flow of combustion air at the
oven vent nor around the base or beneath the lower front panel of the range. Avoid touching the vent
openings or nearby surfaces as they may become hot while the oven is in operation. This range requires fresh air for proper burner combustion.
Never leave children alone or unattended
in the area where an appliance is in use. As children
grow, teach them the proper, safe use of all appliances. Never leave the oven door open when the range is unattended.
Stepping, leaning or sitting on the doors or drawers of this range can result in serious injuries and can also cause damage to the range.
Do not store items of interest to children in the
cabinets above the range. Children could be seriously
burned climbing on the range to reach items.
To eliminate the need to reach over the surface
burners, cabinet storage space above the burners should be avoided.
Adjust surface burner flame size so it does not
extend beyond the edge of the cooking utensil.
Excessive flame is hazardous.
Do not use the oven as a storage space. This creates
a potentially hazardous situation.
Never use your range for warming or heating the
room. Prolonged use of the range without adequate ventilation can be dangerous.
Do not store or use gasoline or other flammable
vapors and liquids near this or any other appliance.
Explosions or fires could result.
Reset all controls to the "off" position after using a
programmable timing operation.
FOR MODELS WITH SELF-CLEAN FEATURE:  Remove broiler pan, food and other utensils before
self-cleaning the oven. Wipe up excess spillage. Follow
the precleaning instructions in the Owner's Guide.
Unlike the standard gas range, THIS COOKTOP IS
NOT REMOVABLE. Do not attempt to remove the cooktop.
DO NOT MAKE ANY ATTEMPT TO OPERATE THE ELECTRIC IGNITION OVEN DURING AN ELECTRICAL POWER FAILURE. RESET ALL OVEN CONTROLS TO "OFF" IN THE EVENT OF A POWER FAILURE.
The electric ignitor will automatically re-ignite the oven burner when power resumes if the oven thermostat control was left in the "ON" position.
When an electrical power failure occurs during use, the surface burners will continue to operate.
During a power outage, the surface burners can be lit with a match. Hold a lighted match to the burner, then slowly turn the knob to the LITE position. Use extreme caution when lighting burners this way.
2
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
Before Starting
Tools You Will Need
For leveling legs and Anti-Tip Bracket:
Adjustable wrench or channel lock pliers  5/16" Nutdriver or Flat Head Screw Driver
Electric Drill & 1/8" Diameter Drill Bit (5/32" Masonry
Drill Bit if installing in concrete)
For gas supply connection:
Pipe wrench
For burner flame adjustment:
Phillips head and
blade-type screwdrivers
For gas conversion (LP/Propane or Natural):
Open end wrench - 1/2"
Additional Materials You Will Need
Gas line shut-off valve  Pipe joint sealant that resists action of LP/Propane gas
A. Locate the Bracket Using the Template - (Bracket may
be located on either the left or right side of the range. Use the information below to locate the bracket if template is not available). Mark the floor or wall where left or right side of the range will be located. If rear of range is against the wall or no further than 1-1/4" from wall when installed, you may use the wall or floor mount method. If molding is installed and does not allow the bracket to fit flush against the wall, remove molding or mount bracket to the floor. For wall mount, locate the bracket by placing the back edge of the template against the rear wall and the side edge of template on the mark made referencing the side of the range. Place bracket on top of template and mark location of the screw holes in wall. If rear of range is further than 1-1/4" from the wall when installed, attach bracket to the floor. For floor mount, locate the bracket by placing back edge of the template where the rear of the range will be located. Mark the location of the screw holes, shown in template.
A new flexible metal appliance conduit (1/2" NPT x 3/
4" or 1/2" I.D.) must be design certified by CSA International. Because solid pipe restricts moving the range we recommend using a new flexible conduit (4 to 5 foot length) for each new installation and additional reinstallations.
Always use the (2) new flare union adapters (1/2" NPT
x 3/4" or 1/2" I.D.) supplied with the new flexible appliance conduit for connection of the range.
Normal Installation Steps
1. Anti-Tip Bracket Installation Instructions Important Safety Warning
To reduce the risk of tipping of the range, the range must be secured to the floor by properly installed anti-tip bracket and screws packed with the range. Failure to install the anti-tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it. Serious injury might result from spilled hot liquids or from the range itself.
If range is ever moved to a different location, the anti-tip brackets must also be moved and installed with the range.
B. Drill Pilot Holes and Fasten Bracket - Drill a 1/8" pilot
hole where screws are to be located. If bracket is to be mounted to the wall, drill pilot hole at an approximate 20° downward angle. If bracket is to be mounted to masonry or ceramic floors, drill a 5/32" pilot hole 1-3/ 4" deep. The screws provided may be used in wood or concrete material. Use a 5/16" nut-driver or flat head screwdriver to secure the bracket in place.
Instructions are provided for installation in wood or cement fastened to either the floor or wall. When installed to the wall, make sure that screws completely penetrate dry wall and are secured in wood or metal. When fastening to the floor or wall, be sure that screws do not penetrate electrical wiring or plumbing.
3
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
C. Level and Position Range - Level range by adjusting
the (4) leveling legs with a wrench. Note: A minimum clearance of 1/8" is required between the bottom of the range and the leveling leg to allow room for the bracket. Use a spirit level to check your adjustments. Slide range back into position. Visually check that rear leveling leg is inserted into and fully secured by the Anti-Tip Bracket by removing lower panel or storage drawer. For models with a warmer drawer or broiler compartment, grasp the top rear edge of the range and carefully attempt to tilt it forward.
2. Provide an adequate gas supply.
This unit is pre-set to operate on 4" natural gas manifold pressure. A convertible pressure regulator is connected to the manifold and MUST be connected in series with the gas supply line. If the LP/Propane conversion kit has been used, follow instructions provided with the kit for converting the pressure regulator to LP/Propane use.
Care must be taken during installation of range not to obstruct the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure. The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure. Examples: If regulator is set for natural gas 4 inch manifold pressure, inlet pressure must be at least 5 inches; if regulator has been converted for LP/Propane gas 10 inch manifold pressure, inlet pressure must be at least 11 inches.
Leak testing of the appliance shall be conducted according to the instructions in step 4g.
3. Seal the openings.
Seal any openings in the wall behind the range and in the floor under the range after gas supply line is installed.
4. Connect the range to the gas supply.
To prevent leaks, put a pipe joint sealant on all male (outside) pipe threads.
Your regulator is in the location shown below.
Do not allow regulator to turn on pipe
when tightening fittings.
The gas supply line should be 1/2" or 3/4" I.D.
4
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
5. Read electrical connection details below and connect electricity to range.
Before servicing, disconnect electrical
supply at circuit breaker, fuse or power cord.
Electric Requirements: An individual, properly grounded and polarized branch circuit protected by a 15 amp. circuit breaker or time delay fuse. See serial plate for proper voltage.
a) Install an external manual gas shut-off valve to gas
supply line in an easily-accessible location outside of the range. Be sure you know how and where to shut-
off the gas supply to the range. b) Install 1/2" flare union adapter to pressure regulator. c) Attach appliance conduit to flare union on regulator. d) Install flare union adapter to external manual shut-off
valve. e) Attach appliance conduit to flare union on shut-off
valve. f) Make sure service shut-off valve on pressure regulator
is in "ON" position. g) Check for leaks. Turn the gas supply on to the range and
use a liquid leak detector at all joints and conduits to
check for leaks in the system.
Do not use a flame to check for gas leaks.
Checking Manifold Gas Pressure
Disconnect the range and its individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 14" of water column pressure (approximately 1/2" psig).
Extension Cord Precautions: Because of potential safety hazards under certain conditions, we strongly recommend against the use of any extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL listed 3-wire grounding type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to or greater than the branch circuit rating. Such extension cords are obtainable through your local service organization.
PLEASE READ CAREFULLY! For personal
safety, this product must be properly grounded.
Grounding Instructions
The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and polarized.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 14" of water column pressure (approximately 1/2" psig).
If it should be necessary to check the manifold gas pressure, connect manometer (water gauge) or other pressure device to the top burner right rear orifice. Using a rubber hose with inside diameter of approximately 1/4," hold tubing down tight over orifice. Turn burner valve on.
For an accurate pressure check have at least two (2) other top burners burning. Be sure the gas supply (inlet) pressure is at least one inch above specified range manifold pressure. The gas supply pressure should never be over 14" water column. When properly adjusted for Natural Gas the manifold pressure is 4." (For LP/Propane Gas the manifold pressure is 10.")
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.
5
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
Operation of Surface Burners
This range is equipped with sealed burners as shown below.
6. Installation of Burner Cap Assembly
Your range may be equipped with either trim rings or burner pans, or trim rings and burner pans. Install pans (some models) and trim rings (some models) as follows:
7. Electric Ignition Surface Burners
Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power. The surface burner gas valves have detent positions in both the Off and LITE positions. The knob must be pushed in to rotate the knob past these detent positions. a. To check for proper lighting, push in and turn a
surface burner knob to the LITE position. You will hear the igniter sparking.
b. The surface burner should light when gas is available to
the top burner. Purge air from supply lines by leaving knob in the LITE position until burner ignites. Each burner should light within four (4) seconds in normal operation after air has been purged from supply lines.
c. Visually check that burner has lit. Once the burner
lights, the control knob should be pushed in and turned out of the LITE position.
d. There are separate electrodes (igniters) for each burner.
Try each knob separately until all burner valves have been checked.
Note: Knob styles may vary from those pictured below.
8. Adjust the "LOW" Setting of Surface Burner Valve (Linear Flow Valves Only):
To Surface Burner
Test to verify if LOW setting should be adjusted a. Push in and turn control to LITE until burner ignites. b. Push in and quickly turn knob to LOWEST POSITION. c. If burner goes out, reset control to OFF. d. Remove the surface burner control knob. e. Insert a thin-bladed screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size can be increased or decreased with the turn of the screw. Turn counterclockwise to increase flame size. Turn clockwise to decrease flame size.
Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame. Flame should be as small as possible without going out.
Note: Air mixture adjustment is not required on surface burners.
6
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
Operation of Oven Burners and Oven Adjustments
9. Electric Ignition Burners
Operation of electric igniters should be checked after range and supply line connectors have been carefully checked for leaks and range has been connected to electric power.
The oven burner is equipped with an electric control system as well as an electric oven burner igniter. If your model is equipped with a waist-high broil burner, it will also have an electric burner igniter. These control systems require no adjustment. When the oven is set to operate, current will flow to the igniter. It will "glow" similar to a light bulb. When the igniter has reached a temperature sufficient to ignite gas, the electrically controlled oven valve will open and flame will appear at the oven burner. There is a time lapse from 30 to 60 seconds after the thermostat is turned ON before the flame appears at the oven burner. When the oven reaches the dial setting, the glowing igniter will go off. The burner flame will go "out" in 20 to 30 seconds after the igniter goes "OFF." To maintain any given oven temperature, this cycle will continue as long as the dial (or display) is set to operate.
The approximate flame length of the oven burner is 1 inch (distinct inner, blue flame).
To determine if the oven burner flame is proper, remove the oven bottom and burner baffle and set the oven to bake at 300°F.
To remove the oven bottom, remove oven hold down screws at rear of oven bottom. Pull up at rear, disengage front of oven bottom from oven front frame, and pull the oven bottom out of the oven. Remove burner baffle so that the burner flame can be observed. If the flame is yellow in color, increase air shutter opening size. (See "2" in illustration below.) If the flame is a distinct blue, reduce the air shutter opening size.
To adjust loosen lock screw (see "3" illustration below), reposition air shutter, and tighten lock screw. Replace oven bottom.
After removing all packing materials and literature from the oven: a) Set oven to BAKE at 300ºF. See Owner's Guide for
operating instructions. b) Within 60 seconds the oven burner should ignite.
Check for proper flame, and allow the burner to cycle
once. Reset controls to off. c) If your model is equipped with a waist-high broiler, set
oven to BROIL. See Owner's Guide for operating
instructions. d) Within 60 seconds the broil burner should ignite.
Check for proper flame. Reset controls to off.
10. Air Shutter-Oven Burner
11.Air Shutter-Broil Burner (if equipped)
The approximate flame length of the broil burner is 1 inch (distinct inner, blue flame).
To determine if the broil burner flame is proper, set the oven to broil.
If the flame is yellow in color, increase air shutter opening size. (See "2" in illustration above.) If the flame is a distinct blue, reduce the air shutter opening size.
To adjust, loosen lock screw (see "3" in illustration above), reposition air shutter, and tighten lock screw.
7
30" GAS RANGE INSTALLATION INSTRUCTIONS
(For Models with Sealed Top Burners)
12.Make Sure Range is Level.
Level the range by placing a level horizontally on an oven rack. Check diagonally from front to back, then level the range by either adjusting the leveling legs or by placing shims under the corners of the range as needed.
13.After installation is complete, make sure all controls are left in the OFF position.
Model and Serial Number Location
For porcelain enamel ovens, the serial plate is located on the right-hand surface of the oven front frame in the broiler or storage drawer area.
For continuous clean ovens, the serial plate is located on the right front edge of the floor shield located in the broiler compartment.
When ordering parts for or making inquires about your range, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your range.
Optional Spice Rack
Some models are equipped with an optional spice rack. Follow the instructions below for installation: a. Using a 1/4" nutdriver or Phillips screwdriver, remove
four (4) screws from rear of range as shown in diagram below.
b. Using these four (4) screws, attach two (2) support
posts (provided) to rear of range.
c. Set rack on support posts and make sure rear end
flanges are around support posts as shown.
Your serial plate also tells you the rating of the burners, the type of fuel and the pressure the range was adjusted for when it left the factory.
Before You Call for Service
Read the Avoid Service Checklist and operating instructions in your Owner's Guide. It may save you time and expense. The list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
Refer to the warranty in your Owner's Guide for our toll-free service number and address. Please call or write if you have inquiries about your range product and/or need to order parts.
Care, Cleaning and Maintenance
Refer to the Owner's Guide for cleaning instructions.
If removing the range is necessary for cleaning or maintenance, shut off gas supply. Disconnect the gas and electrical supply. If the gas or electrical supply is inaccessible, lift the unit slightly at the front and pull out away from the wall. Pull only as far as necessary to disconnect the gas and electrical supply. Finish removing the unit for servicing and cleaning. Reinstall in reverse order making sure to level the range and check gas connections for leaks. See page 3, step 1 for proper anchoring instructions.
8