PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Capacitor Run or
Induction Run
Operating Time 25 to 35%
Freezer Temperature 2° to 8°F (-17° to -13°C)
Refrigerator Temperature 35° to 40°F (2° to 4°C)
Low Side Pressure (cut-in)
Low Side Pressure (cutout)
High Side Pressure (last
1/3 cycle)
Wattage (last 1/3 cycle) 140 to 185
Amps (running) 1.1 to 1.6
Base Voltage
Cabinet Size
18’, 20’ & 21’
15’ & 16’
Mechanical Timer - Defrost 30 minutes every 10 hours of compressor run time.
Electronic Timer (ADC) - Defrost up to 24 minutes every 6-72 hours of compressor
Watts RPM
2.3
Electrical 115 vac (127 vac max) 60 Hertz
Ice maker with
Thermostat
Heater Wattage 165 W
black housing
Ice maker with
white housing
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color
1 Green / Yellow
2 Yellow
3 Black
4 Light Blue
65°F (18°C) Ambient
8 to 16 psig ( 55 to
110 kPa)
1 to 4 psig (7 to 28
kPa)
110 to 120 psig (758
to 827 kPa)
115 vac (127 vac
max)
DEFROST SPECIFICATIONS
Thermostat
Cut-in Cut-out Ohms
9°F
(-2°C)
29°F
(-2°C
CONDENSER FAN MOTOR
1100 CW Opposite
ICE MAKER SPECIFICATIONS
Opens at 52°F (11°C) Closes at 12°F ( -11°C)
Opens at 48°F (8.9°C) Closes at 9°F ( -12.8°C)
50°F
(10°C)
50°F
(10°C)
run time.
Shaft
35
41
SERVICE DATA SHEET
241588207
STANDARD - AUTOMATIC DEFROST
TOP MOUNT FREEZER - R134a
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel
only. Untrained persons should not attempt to make repairs due to the possibility of
electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned
to their original position and properly secured.
NOTE
Some products come equipped with an Electronic Defrost Control. To initiate defrost,
depress the fresh food light switch 5 times in 6 seconds (light bulb must be working).
To terminate defrost, depress the fresh food light switch 5 times in 6 seconds.
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO NOT allow
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F.
Excessive heat will distort the plastic liner.
BLUE
BLUE
DK. BLUE
BLUE
YELLOW YELLOW
BLUE
IMPORTANT
PLEASE RETURN THIS SHEET TO ITS ORIGINAL
LOCATION.
ICE MAKER INFORMATION
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. Use screwdriver to rotate motor gear counterclockwise
until holding switch circuit is completed. All components of ice maker should func-
tion to complete the cycle.
Water Fill Volume: The
water ll adjustment screw will
change the ll time. One full turn
is equal to 20cc (.68 oz.). The
correct ll is 102 to 130cc (3.4 to
4.3 oz.). When a water valve is
replaced, the ll volume must be
checked.
COMPRESSOR WIRING
Induction Run Compressor with RelayP.T.C. STARTER WITH RUN CAPACITOR