Frigidaire FFTH1022U2 Specification Sheet

FFTH1022U2
HOME COMFORT
THROUGH-THE-WALL AIR CONDITIONER/HEATER
PRODUCT DIMENSIONS
Height 14-9/16"
Width 24"
Depth 20-5/8"
MORE EASY-TO-USE FEATURES
Supplemental Heating Option
With our supplemental heating capability, you can be comfortable regardless of the temperature outside — you have both heating and cooling solutions!
Sleep Mode
With Sleep Mode, the temperature gradually increases a few degrees over the evening, saving energy and creating a comfortable environment during the evening hours.
Remote Control
Offers you the flexibility to control the temperature and fan speed from anywhere in the room.
SIGNATURE FEATURES
Eortless™ Temperature Control
Our air conditioners maintain the preset room temperature, so you will remain comfortable at all times.
Programmable 24-Hour On/O Timer
With the 24-Hour On/Off Timer, you can ensure your home will be cool and comfortable when you want it to be without having to worry about running up your utility bills. The built-in timer allows you to preset the unit to turn on and off in half-hour increments.
Energy Saver Mode
Reduce your utility bills in this mode. It cools similarly to central air, with the unit turning on and off at different intervals to ensure the room temperature stays at the set temperature.
Multi-Speed Fan
Features three different fan speeds, for more cooling flexibility.
Easy-to-Clean Washable Filter
apture dust from the air and keep your air
C conditioner working efficiently with our easy­to-clean washable filter.
Power Cord
Comes with an extra long three-prong cord — makes extension cords unnecessary.
Eortless™ Restart
Automatically resumes operating at its previous settings when power is restored to your unit.
Clean Filter Alert
Alert notifies you when your filter needs to be cleaned so you don’t have to keep track of it yourself.
Ready-Select® Controls
Easily select options with the touch of a button.
PERFORMANCE BTUs
Cool 10,000 / 9,800
Heat 10,600 / 8,600
frigidaire.com
D
A
C
B
FFTH1022U2
Plug Type (NEMA)
6-20P
HOME COMFORT
THROUGH-THE-WALL AIR CONDITIONER/HEATER
PERFORMANCE
BTU (Cool) 10,000 / 9,800 BTU (Heat) 10,600 / 8,600 Dehumidification (Pints / Hour) 2.2 Cool Area (Up To Sq. Ft.) 450 Combined Energy Eciency Ratio 9.6
Energy Eciency Ratio 9.6
ELECTRICAL
Volts 230 / 208 Amps (Cool) 4.6 / 5.0 Amps (Heat) 15.8 / 14.5 Watts (Cool) 1,040 / 1,020 Watts (Heat) 3,450 / 2,820 Length of Power Cord (Min. / Max.) 5.5' / 6' Plug Type (NEMA) LCDI (6-20P)
FEATURES
Electronic Controls Ready-Select® Controls Fan Speeds (Cool / Fan / Heat) 3 / 3 / 3 Low Voltage Start-Up Yes Auto Cool Function Yes Energy Saver Mode Yes Sleep Mode Yes Filter Check Yes 24-Hour On / O Timer Yes Clean Air Ionizer Remote Control Full-Function with Heat Air CFM (High / Med / Low) 290 / 265 / 253 Air Direction Control 6-Wa y Fresh Air / Exhaust Vent / Closed No / No / Yes Filter Type
Filter Access Slide-Out Slide-Out Chassis
1
Warranty
Easy-to-Clean Washable Filter
Yes
OPTIONAL ACCESSORIES
Through-The-Wall 18" Sleeve Kit PN # 5304514430 Trim Kit (for larger existing sleeve) Included Architectural-Style Exterior Louvered Grille PN # 5304515640
CERTIFICATIONS
Performance AHAM
SPECIFICATIONS
Refrigerant R410a Shipping Weight (Approx.) 91 Lbs.
1
Warranty five (5) years full parts and labor.
PRODUCT DIMENSIONS
A - Height 14-9/16" B - Width 24" C - Depth 20-5/8" D - Max. Wall Thickness 18"
SLEEVE CUTOUT DIMENSIONS
Height 15-5/8" Width 25-15/16"
USA CANADA
10200 David Taylor Drive
5855 Terry Fox Way
Charlotte, NC 28262
Mississauga, ON L5V 3E4
1-800-FRIGIDAIRE
1-800-265-8352
frigidaire.com
frigidaire.ca
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change. Accessories information available on the web at frigidaire.com
© 2018 Electrolux Home Products, Inc.
FFTH1022U2 03/20
RAC Through-The-Wall “U” Models Frigidaire Baseline
24"
14
9/16"
20
5/8"
Wall (thickness)
18"
max.
Wall
Through-The-Wall Installation
Adjustable
mounting
brackets
Locking clip
Sleeve-to-unit seal
Building construction support
Outside closure panel
Through-The-Wall 18" Sleeve Kit
(PN # 5304514430)
FFTH1022U2
Plug Type (NEMA)
6-20P
HOME COMFORT
THROUGH-THE-WALL AIR CONDITIONER/HEATER
Product Shipping Weight (approx.) – 91 Lbs.
Single phase 3-wire cable, 230 / 208 Volt, 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line.
Amps @ 230 / 208 Volts = (Cool) 4.6 / 5.0 Amps / (Heat) 15.8 / 14.5 Amps
Recommended Circuit Breaker – 20 Amps
Unit equipped with 230 / 208V 3-wire power supply cord, NEMA plug type 6-20P, approximately 72” long.
Unit’s increased performance characteristics result from two rear intakes. For unit to operate at maximum efficiency, carefully follow complete, detailed new or replacement installation instructions provided in Product Installation Guide on web.
Unit requires rearward slope when installation is complete, to allow condensate to drain from rear of sleeve.
NEW INSTALLATION
For new installation, Frigidaire® Through-The-Wall 18" Sleeve Kit PN # 5304514430 available. Recommended for proper installation.
Through-the-wall installation requires 18" maximum wall thickness.
For energy-saving purposes, install unit in shady location, preferably a northern exposure; and do not block airflow inside with blinds, curtains or furniture; or outside with shrubs, enclosures or other buildings.
USA
10200 David Taylor Drive
CANADA
5855 Terry Fox Way
Charlotte, NC 28262 Mississauga, ON L5V 3E4
INSTALLATION SPECIFICATIONS
REPLACEMENT INSTALLATION
When replacing existing air conditioner with new unit, refer to Product Installation Guide on web to identify existing wall-sleeve manufacturer and size compatibility. If proper installation and slope are suspect, then correct installation of Frigidaire® Through-The-Wall 18” Sleeve Kit PN # 5304514430 recommended.
Use of existing wall sleeve to mount new unit requires original sleeve be in sound structural condition with rear grille that attaches securely, or rear flange that serves as stop for unit.
Preferable installation option, for increased efficiency and possibility of drafts reduced, requires existing rear grille (mounted to sleeve) be replaced
1-800-FRIGIDAIRE
1-800-265-8352
frigidaire.com
frigidaire.ca
with new unit’s rear air-directional louvered grille (provided in accessory kit, shipped with unit). Non-preferable installation option of directly mounting rear
louvered grille to unit can be considered, requiring grille be mounted to unit prior to sleeve installation.
Existing decorative exterior grille may be left in place, provided that proper air-directional rear louvered grille is installed.
For installation into larger existing sleeve, optional Trim Kit PN # EA120T available.
OPTIONAL ACCESSORIES
Through-The-Wall 18" Sleeve Kit – (PN # 5304514430).
Trim Kit (for larger existing sleeve) – Included.
Architectural-Style Exterior Louvered Grille – (PN # 5304515640).
Note: For planning purposes only. Always consult local and national electric, gas and plumbing codes.
Refer to Product Installation Guide for detailed installation instructions on the web at frigidaire.com.
Specifications subject to change. Accessories information available on the web at frigidaire.com
© 2018 Electrolux Home Products, Inc.
FFTH1022U2 03/20
Loading...