Français ........................................................... 25
Español ........................................................... 49
137441900C (1304)
IMPORTANT SAFETY INSTRUCTIONS
WARNING
For your safety the information in this manual must be followed to minimize the risk of fi re or explosion or to prevent
property damage, personal injury or loss of life. Do not store or use gasoline or other fl ammable vapors and liquids in
the vicinity of this or any other appliance.
WARNING - RISK OF FIRE
Read all of the following instructions before installing and using this appliance:
• Destroy the carton and plastic bags after the dryer is unpacked. Children might use them for play. Cartons covered
with rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation. Place all materials in a
garbage container or make materials inaccessible to children.
• Clothes dryer installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
• Install the clothes dryer according to the manufacturer’s instructions and local codes.
• The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70, or in Canada, the Canadian electrical code C22.1 part 1.
• The gas service to the dryer must conform with local codes and ordinances and the latest edition of the National
Fuel Gas Code ANSI Z223.1, or in Canada, CAN/ACG B149.1-2000. An individual manual shut-off valve must be
installed within 6 ft (1.83 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
• The dryer is designed under ANSI Z 21.5.1 or ANSI/UL 2158 - CAN/CSA C22.2 No. 112 (latest editions) for HOME
USE only. This dryer is not recommended for commercial applications such as restaurants, beauty salons, etc.
• Do not install a clothes dryer with fl exible plastic or fl exible foil venting material. Flexible venting materials are
known to collapse, be easily crushed and trap lint. These conditions will obstruct clothes dryer airfl ow and increase
the risk of fi re.
• Do not stack a dryer on top of washer already installed on pedestal. Do not stack dryer on top of another dryer.
Do not stack washer on top of dryer. Do not stack washer on top of another washer. Do not stack dryer on top of
washer without use of manufacturer approved and correctly installed stacking kit appropriate for your model.
• The instructions in this manual and all other literature included with this dryer are not meant to cover every
possible condition and situation that may occur. Good safe practice and caution MUST be applied when installing,
operating and maintaining any appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Clear the room, building or area of all occupants.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re
department.
CAUTION
To avoid back or other injury, have more than one
person move or lift the appliance.
EXCESSIVE WEIGHT HAZARD
Save these instructions
for future reference.
Tools and materials needed for installation:
Pre-Installation Requirements
• Adjustable pliers
• Phillips, straight, & square bit
screwdrivers
• Adjustable wrench
• Pipe wrench for gas supply (gas
dryer)
• LP-resistant thread tape (for natural
gas or LP supply, gas dryer)
2
• Carpenter’s level
• External vent hood
• 4-inch (102 mm), rigid metal or
semi-rigid metal exhaust duct work
• 3-wire or 4-wire 240 volt cord kit
(electric dryer)
• 4 in. (102 mm) clamp
• Gas line shutoff valve (gas dryer)
• ½ NPT union fl are adapters (x2)
and fl exible gas supply line (gas
dryer)
• Metal foil tape (not duct tape)
IMPORTANT SAFETY INSTRUCTIONS
WARNING
Please read all instructions before using this dryer.
Recognize safety symbols, words
and labels
Safety items throughout this manual are labeled with
a WARNING or CAUTION based on the risk type as
described below:
Defi nitions
This is the safety alert symbol. It is used to alert
you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury
or death.
DANGER
DANGER indicates an imminently hazardous situation
which, if not avoided, will result in death or serious
injury.
WARNING
WARNING indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
CAUTION
CAUTION indicates a potentially hazardous situation
which, if not avoided, may result in minor or moderate
injury.
IMPORTANT
IMPORTANT indicates installation, operation or
maintenance information which is important but not
hazard-related.
Installation Checklist
Exhaust Venting
Free-fl owing, clear of lint buildup 4 inch (102 mm) rigid or semi-rigid ducting of
minimal length and turns
NO foil or plastic venting material
Approved vent hood exhausted to outdoors
Leveling
Dryer is level, side-to-side and front-to-back
Cabinet is setting solid on all corners
Gas Supply (Gas Dryer)
Manual shutoff valve present in supply
All connections sealed with approved sealer and
wrench tight
Conversion kit for LP system
Gas supply turned on
No leaks present at all connections -
check with soapy water, NEVER check with fl ame
240v Electric Supply (Electric Dryer)
Approved NEMA 10-30R or 14-30R service cord
with all screws tight on terminal block
Approved strain relief installed
Terminal access cover installed before initial
operation
Door Reversal
Follow detailed instructions in this guide
Test hinge and latch for function
Electrical Power
House power turned on
Dryer plugged in
Final Checks
Installation Instructions
Guide
read thoroughly
Door latches and drum tumbles when cycle
starts
Registration card sent in
and
Use and Care
3
INSTALLATION REQUIREMENTS
NOTE
Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered
generators, solar powered generators, wind powered generators or any other generator other than the local utility
company is not recommended.
Electrical requirements for electric dryer
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately
fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY - 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
IMPORTANT
This dryer is internally grounded to neutral unless it was manufactured for sale in Canada.
Only a 4-conductor cord shall be used when the appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the neutral link is prohibited for: (1) new branch circuit
installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding
through the neutral.
OUTLET RECEPTACLE - NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord is accessible
when the dryer is in the installed position.
GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a 3-conductor power
supply cord NEMA 10-30 type SRDT rated at 240
volt AC minimum, 30 amp, with 3 open end spade
lug connectors with upturned ends or closed
loop connectors and marked for use with clothes
dryers. For 3-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor power supply
cord NEMA 14-30 type SRDT or ST (as required) rated
at 240 volt AC minimum, 30 amp, with 4 open end
spade lug connectors with upturned ends or closed
loop connectors and marked for use with clothes
dryers. For 4-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM.
NOTE
Dryers manufactured for sale in Canada have factoryinstalled, 4-wire power supply cord (NEMA 14-30R).
4
INSTALLATION REQUIREMENTS
Grounding type
ll receptacle
wer cord with
3-prong grgr
ounded plug
Do not,
under
y cir
cumstances,
cut,
removeve,
or b
ypass the
ounding pr
ong.
Electrical requirements for gas dryer
CIRCUIT - Individual, properly polarized and grounded
15 amp. branch circuit fused with 15 amp. time delay
fuse or circuit breaker.
POWER SUPPLY - 2-wire, with ground, 120 volt, single
phase, 60 Hz, Alternating Current.
POWER SUPPLY CORD - The dryer is equipped with a 120
volt 3-wire power cord.
GROUNDING CONNECTION - See “Grounding
requirements” in Electrical Installation section.
Gas supply requirements
WARNING
Uncoated copper tubing will corrode when subjected
to natural gas, causing gas leaks. Use ONLY black iron,
stainless steel, or plastic-coated brass piping for gas
supply.
1 Installation MUST conform with local codes, or in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 (latest edition).
2 The gas supply line should be 1/2 inch (1.27 cm)
pipe.
3 If codes allow, fl exible metal tubing may be used
to connect your dryer to the gas supply line. The
tubing MUST be constructed of stainless steel or
plastic-coated brass.
EXPLOSION HAZARD
Grounding type
wawall receptacl
PoPower cord with
3-prong
4 The gas supply line MUST have an individual
shutoff valve installed in accordance with the
B149.1, Natural Gas and Propane Installation Code.
5 A 1/8 inch (0.32 cm) N.P.T. plugged tapping,
accessible for test gauge connection, MUST be
installed immediately upstream of the gas supply
connection to the dryer.
6 The dryer MUST be disconnected from the gas
supply piping system during any pressure testing
of the gas supply piping system at test pressures in
excess of 1/2 psig (3.45 kPa).
7 The dryer MUST be isolated from the gas supply
piping system during any pressure testing of the
gas supply piping system at test pressures equal to
or less than 1/2 psig (3.45 kPa).
8 Connections for the gas supply must comply with
the Standard for Connectors for Gas Appliances,
ANSI Z21.24.
Do not,
anany cir
cut,
or b
ypass th
grgrounding pr
ounded plug
under
cumstances,
remo
ong.
5
INSTALLATION REQUIREMENTS
Exhaust system requirements
Use only 4 inch (102 mm) diameter (minimum) rigid
or fl exible metal duct and approved vent hood which
has a swing-out damper(s) that open when the dryer
is in operation. When the dryer stops, the dampers
automatically close to prevent drafts and the entrance
of insects and rodents. To avoid restricting the outlet,
maintain a minimum of 12 inches (30.5 cm) clearance
between the vent hood and the ground or any other
obstruction.
WARNING
Failure to follow these instructions can create excessive
drying times and fi re hazards.
The following are specifi c requirements for proper
and safe operation of your dryer.
FIRE HAZARD
WARNING
Do not install a clothes dryer with fl exible plastic or
metal foil venting materials. Flexible venting materials
are known to collapse, be easily crushed and trap lint.
These conditions will obstruct clothes dryer airfl ow and
increase the risk of fi re.
If your present system is made up of plastic duct or
metal foil duct, replace it with a rigid or semi-rigid metal
duct. Also, ensure the present duct is free of any lint prior
to installing dryer duct.
FIRE HAZARD
CorrectIncorrect
CorrectIncorrect
6
INSTALLATION REQUIREMENTS
Exhaust system requirements, continued
WARNING
A clothes dryer must be exhausted outdoors. Do not
exhaust dryer into a chimney, a wall, a ceiling, an attic,
a crawl space or any concealed space of a building. A
clothes dryer produces combustible lint. If the dryer is
not exhausted outdoors, some fi ne lint will be expelled
into the laundry area. An accumulation of lint in any
area of the home can create a health and fi re hazard.
The dryer must be connected to an exhaust outdoors.
Regularly inspect the outdoor exhaust opening and
remove any accumulation of lint around the outdoor
exhaust opening and in the surrounding area.
FIRE HAZARD
WARNING
Exceeding the length of duct pipe or number of elbows
allowed in the “MAXIMUM LENGTH” charts can cause
an accumulation of lint in the exhaust system. Plugging
the system could create a fi re hazard, as well as
increase drying times.
Number of 90° turns
FIRE HAZARD
MAXIMUM LENGTH
of 4” (102mm) Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
WARNING
• Do not allow combustible materials (for example:
clothing, draperies/curtains, paper) to come in
contact with exhaust system. The dryer MUST NOT
be exhausted into a chimney, a wall, a ceiling,
or any concealed space of a building which can
accumulate lint, resulting in a fi re hazard.
• Do not screen the exhaust ends of the vent system,
or use any screws, rivets or other fasteners that
extend into the duct to assemble the exhaust
system. Lint can become caught in the screen, on
the screws or rivets, clogging the duct work and
creating a fi re hazard as well as increasing drying
times. Use an approved vent hood to terminate the
duct outdoors, and seal all joints with metal foil duct
tape. All male duct pipe fi ttings MUST be installed
downstream with the fl ow of air.
FIRE HAZARD
4”
(102mm)louvered
064 ft. (19.5 m)48 ft. (14.6 m)
152 ft. (15.9 m)40 ft. (12.2 m)
244 ft. (13.5 m)32 ft. (9.8 m)
336 ft. (11 m)24 ft. (7.3 m)
428 ft. (9.5 m)16 ft. (4.9 m)
2.5”
(6.35cm)
WARNING
• Do not install fl exible plastic or fl exible foil venting
material.
• If installing semi-rigid venting, do not exceed 8 ft.
(2.4 m) duct length.
FIRE HAZARD
7
INSTALLATION REQUIREMENTS
Exhaust system requirements, continued
Install male fi ttings in correct direction:
Exhaust direction
Directional exhausting can be accomplished by installing
a quick-turn 90° dryer vent elbow directly to exhaust
outlet of dryer. Dryer vent elbows are available through
your local parts distributor or hardware store.
CORRECT
In installations where the exhaust system is not described
in the charts, the following method must be used to
determine if the exhaust system is acceptable:
1 Connect an inclined or digital manometer between
the dryer and the point the exhaust connects to the
dryer.
2 Set the dryer timer and temperature to air fl uff
(cool down) and start the dryer.
3 Read the measurement on the manometer.
4 The system back pressure MUST NOT be higher
than 0.75 inches of water column. If the
system back pressure is less than 0.75 inches of
water column, the system is acceptable. If the
manometer reading is higher than 0.75 inches of
water column, the system is too restrictive and the
installation is unacceptable.
Although vertical orientation of the exhaust system is
acceptable, certain extenuating circumstances could
affect the performance of the dryer:
• Only rigid metal duct work should be used.
• Venting vertically through a roof may expose the
exhaust system to down drafts causing an increase
in vent restriction.
• Running the exhaust system through an
uninsulated area may cause condensation and
faster accumulation of lint.
• Compression or crimping of the exhaust system will
cause an increase in vent restriction.
• The exhaust system should be inspected and
cleaned a minimum of every 18 months with
normal usage. The more the dryer is used, the
more often you should check the exhaust system
and vent hood for proper operation.
INCORRECT
See also
Clearance Requirements
NOTE
Use of 90° quick-turn
elbow is required to meet
minimum installation
depth of free-standing
dryer.
on the next page.
8
INSTALLATION REQUIREMENTS
Manufactured or mobile home installation
1 Installation MUST conform to current Manufactured
Home Construction & Safety Standard, Title 24
CFR, Part 32-80 (formerly the Federal Standard
for Mobile Home Construction and Safety, Title 24,
HUD Part 280) or Standard CAN/CSAZ240 MH.
2 Dryer MUST be exhausted outside (outdoors, not
beneath the mobile home) using metal ducting
that will not support combustion. Metal ducting
must be 4 inches (10.16 cm) in diameter with no
obstructions. Rigid metal duct is preferred.
3 If dryer is exhausted through the fl oor and area
beneath the mobile home is enclosed, the exhaust
Clearance requirements
system MUST terminate outside the enclosure with
the termination securely fastened to the mobile
home structure.
4 Refer to previous sections in this guide for other
important exhaust venting system requirements.
5 When installing a gas dryer into a mobile home, a
provision must be made for outside make up air.
This provision is to be not less than twice the area
of the dryer exhaust outlet.
6 Installer MUST anchor this (1) dryer or (2) dryer
mounted on pedestal to the fl oor with approved
Mobile Home Installation Kit - P/N 137067200.
WARNING
Do not install the dryer where gasoline or other
fl ammables are kept or stored. If the dryer is installed
in a garage, it must be a minimum of 18 inches (45.7
cm) above the fl oor. Failure to do so can result in
death, explosion, fi re or burns.
EXPLOSION HAZARD
IMPORTANT
DO NOT INSTALL YOUR DRYER:
1 In an area exposed to dripping water or outside
weather conditions.
2 In an area where it will come in contact with
curtains, drapes, or anything that will obstruct
the fl ow of combustion and ventilation air.
3 On carpet. Floor MUST be solid with a maximum
slope of 1 inch (2.5 cm).
9
INSTALLATION REQUIREMENTS
Clearance requirements, continued
Installation in a Recess or Closet
1 A dryer installed in a bedroom, bathroom, recess or
closet, MUST be exhausted outdoors.
2 No other fuel burning appliance shall be installed in
the same closet as the gas dryer.
3 Your dryer needs the space around it for proper
ventilation.
DO NOT install your dryer in a closet with a solid door.
4 Closet door ventilation required: A minimum
of 120 square inches (774.2 cm²) of opening,
equally divided at the top and bottom of the
door, is required. Openings should be located 3
inches (7.6 cm) from bottom and top of door.
Openings are required to be unobstructed when a
door is installed. A louvered door with equivalent
air openings for the full length of the door is
acceptable.
* For other than straight back venting, a quick-turn 90°
SIDESREARTOPFRONT
0” (0 cm) 0” (0 cm)* 0” (0 cm)n/a
dryer vent elbow (vented right or down in free-standing
dryer or right on pedestal-mounted dryer) must be
installed to achieve 0” (0 cm) installation.
0”
(0cm)
0”
(0cm)
1”
(2.54cm)
(0cm)
0”
10
NOTE
To achieve an installation with 0” (0 cm) clearance
for the back of the dryer (for other than straight back
venting), a quick-turn 90° dryer vent elbow must be
installed as described previously in this manual.
Dryer Dimensions
INSTALLATION REQUIREMENTS
51.4” (131 cm)*
to clear open door
freestand dryer
on fl oor
fl oor line
dryer mounted on
optional pedestal
fl oor line
51.4” (131 cm)*
to clear open door
30.3” (77 cm)*
to front of closed door
30.3” (77 cm)*
to front of closed door
51.25”
(130 cm)
71.5”
(182 cm)
36.0”
(91.5 cm)
gas supply
pipe on rear
of gas unit
water supply
connection on
rear of unit
gas supply
pipe on rear
of gas unit
17.0”
(43 cm)
1.6”
(4 cm)
(68.5 cm)
3.75”
(9.5 cm)
27.0”
27.0”
(68.5 cm)
13.50”
(34.5 cm)
to center of
rear vent
electrical
supply on
rear of unit
centerline
height for
rear vent
3.7”
(9.5 cm)
(48 cm)
electrical
supply on
rear of unit
centerline
height for
rear vent
1
19.0”
1
fl oor line
*Connection of water inlet hose on steam dryer adds 3/4 in. (2 cm) to installation depth.
1
Power supply cord length on gas dryer approximately 60 inches (152.5 cm).
2
Drain hose length on washer approximately 59 inches (150 cm).
3
Power supply cord length on washer approximately 60 inches (152.5 cm).
37”
(94 cm)
drain hose on
rear of unit
power
cord on
2
rear of
3
unit
39”
(99 cm)
11
INSTALLATION INSTRUCTIONS
Electrical installation
The following are specifi c requirements for proper and
safe electrical installation of your dryer. Failure to follow
these instructions can create electrical shock and/or a
fi re hazard.
WARNING
• This appliance MUST be properly grounded.
• Do not use an extension cord with this dryer. Some
Grounding requirements - Electric dryer (USA)
ELECTRICAL SHOCK HAZARD
Electrical shock can result if the dryer is not properly
grounded. Follow the instructions in this manual for
proper grounding.
extension cords are not designed to withstand the
amounts of electrical current this dryer utilizes
and can melt, creating electrical shock and/
or fi re hazard. Locate the dryer within reach of
the receptacle for the length power cord to be
purchased, allowing some slack in the cord. Refer to
the pre-installation requirements in this manual for
the proper power cord to be purchased.
WARNING
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check
with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
For a grounded, cord-connected dryer:
1 The dryer MUST be grounded. In the event of a
2 After you purchase and install a 3 wire or 4 wire
ELECTRICAL SHOCK HAZARD
malfunction or breakdown, grounding will reduce
the risk of electrical shock by a path of least
resistance for electrical current.
power supply cord having an equipment-grounding
conductor and a grounding plug that matches you
WARNING
• A U.L.-approved strain relief must be installed onto
power cord. If the strain relief is not attached, the
cord can be pulled out of the dryer and can be cut
by any movement of the cord, resulting in electrical
shock.
• Do not use an aluminum wired receptacle with a
copper wired power cord and plug (or vice versa).
A chemical reaction occurs between copper and
aluminum and can cause electrical shorts. The
proper wiring and receptacle is a copper wired
power cord with a copper wired receptacle.
NOTE
Dryers operating on 208 volt power supply will have
longer drying times than dryers operating on 240 volt
power supply.
wiring system, the plug MUST be plugged into
an appropriate, copper wired receptacle that is
properly installed and grounded in accordance with
all local codes and ordinances. If in doubt, call a
licensed electrician.
3 DO NOT modify the plug you’ve installed on this
appliance. If it will not fi t the outlet, have a proper
outlet installed by a qualifi ed electrician.
For a permanently connected dryer:
1 The dryer MUST be connected to a grounded
metal, permanent wiring system; or an equipment
grounding conductor must be run with the circuit
conductors and connected to the equipmentgrounding terminal or lead on the appliance.
ELECTRICAL SHOCK HAZARD
12
INSTALLATION INSTRUCTIONS
Grounding type
ll receptacle
wer cord with
3-prong grgr
ounded plug
Do not,
under
y cir
cumstances,
cut,
removeve,
or b
ypass the
ounding pr
ong.
Grounding requirements - Electric dryer (Canada)
WARNING
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock. Check
with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
For a grounded, cord-connected dryer:
1 The dryer MUST be grounded. In the event of a
ELECTRICAL SHOCK HAZARD
malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance
for electrical current.
2 Since your dryer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug must be plugged into
an appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances. If in doubt, call a licensed electrician.
3 DO NOT modify the plug provided with this
appliance. If it will not fi t the outlet, have a proper
outlet installed by a qualifi ed electrician.
Grounding requirements - Gas dryer (USA and Canada)
1 The dryer is equipped with a three-prong
(grounding) plug for your protection against shock
hazard and should be plugged directly into a
properly grounded three-prong receptacle.
2 The plug must be plugged into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances. If
in doubt, call a licensed electrician.
3 DO NOT modify the plug provided with this
appliance. If it will not fi t the outlet, have a proper
outlet installed by a qualifi ed electrician.
Grounding type
wawall receptacl
PoPower cord with
3-prong
ounded plug
Do not,
under
anany cir
cumstances,
cut,
remo
or b
ypass th
grgrounding pr
ong.
13
INSTALLATION INSTRUCTIONS
Gas connection
1 Remove the shipping cap from gas pipe at the rear
of the dryer.
IMPORTANT
DO NOT connect the dryer to L.P. gas service without
converting the gas valve. An L.P. conversion kit must
be installed by a qualifi ed gas technician.
2 Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or
approved pipe from gas supply line to the 3/8 inch
(0.96 cm) pipe located on the back of the dryer.
Use a 1/2 inch to 3/8 inch (1.27 cm to 0.96 cm)
reducer for the connection. Apply an approved
thread sealer that is resistant to the corrosive
action of liquefi ed gases on all pipe connections.
Flare
Union
elppiN
GAS FLOW
Flexible
Connector
Flare
Union
Inlet Pipe on
Back of Dryer
Manual
Shuto
Valve
Closed
Open
All connections must be wrench-tightened
IMPORTANT
The supply line must be equipped with an approved
manual shutoff valve. This valve should be located in
the same room as the dryer and should be in a location
that allows ease of opening and closing. Do not block
access to the gas shutoff valve.
3 Open the shutoff valve in the gas supply line to
allow gas to fl ow through the pipe. Wait a few
minutes for gas to move through the gas line.
to dryer
from gas supply
Shuto Valve -
Open position
4 Check for gas system leaks with a manometer. If a
manometer is not available, test all connections by
brushing on a soapy water solution.
WARNING
NEVER test for gas leaks with an open fl ame.
EXPLOSION HAZARD
14
INSTALLATION INSTRUCTIONS
Water connection (Steam Model only)
WATER SUPPLY REQUIREMENTS
Cold water faucet MUST be installed within 42 inches
(107 cm) of your dryer’s water inlet. The faucet MUST be
3/4 inch (1.9 cm) with threading for laundry hose connection. Water pressure MUST be between 30 and 120
psi. Your water department can advise you of your water
pressure.
1 Turn off COLD water supply to washer.
2 Remove COLD inlet hose from COLD water supply
and inspect for rubber washer. Replace washer if it
is torn or worn out.
RUBBER WASHER
MUST BE PRESENT
AND UNDAMAGED
COLD INLET HOSE
TO WASHER
3 Momentarily turn on COLD supply and run some
water into a bucket or container to clear any
contaminants in the line.
4 Remove hose kit from dryer drum and inspect hose
couplings for proper placement of rubber washers.
RUBBER WASHERS
MUST BE PRESENT
15
INSTALLATION INSTRUCTIONS
Water connection, continued (Steam Model only)
5 If your installation has room for the COLD water
supply to accept the “Y” connector directly, thread
the “Y” connector to the COLD water supply and
snug it by hand; then tighten it another 2/3 turn
with pliers.
NOTE
If you were able to install the “Y” connector directly to
the COLD water supply, please skip to step 8.
6 If there is not room to install the “Y” connector
directly, thread a short extension hose on to the
COLD water supply and snug it by hand; then
tighten it another 2/3 turn with pliers.
NOTE
Short extension available from your local hardware
supplier. Extension hose must meet qualifi cations for
use in laundry installation.
7 Thread the “Y” connector to the short extension
hose and snug it by hand; then tighten it another
2/3 turn with pliers.
8 Connect the COLD inlet hose for the washer to the
“Y” connector and snug it by hand; then tighten it
another 2/3 turn with pliers.
9 Connect the straight end of the long hose from the
kit to the other outlet on the “Y” connector and
snug it by hand. Connect the hose’s 90° coupling to
the brass water inlet on the back of the dryer and
snug it by hand. Tighten each connection of the
dryer inlet hose another 2/3 turn with pliers.
10 Turn on the water and check for leaks at all
connections.
DIRECT CONNECTION
OR WITH EXTENSION*
WATER INLET
ON DRYER
COLD WATER SUPPLY
HOSE TO WASHER
*Laundry hose extension not included with dryer.
16
INSTALLATION INSTRUCTIONS
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Terminal
block
Neutral
(center wire)
30 AMP
NEMA 10-30
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
Electrical connection (non-Canada) - 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
WARNING
Failure to disconnect power source before servicing
could result in personal injury or even death.
Do not make a sharp bend or crimp wiring/conductor
at connections.
ELECTRICAL SHOCK HAZARD
1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block
access cover in the lower corner on the back of the
dryer.
3 Install a UL-approved strain relief according to the
power cord/strain relief manufacturer’s instructions
in the power cord entry hole below the access
panel. At this time, the strain relief should be
loosely in place.
4 Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 10-30 type SRDT, through the
strain relief.
5 Attach the power cord neutral (center wire)
conductor to the SILVER colored center terminal on
the terminal block. Tighten the screw securely.
6 Attach the remaining two power cord outer
conductors to the outer, BRASS colored terminals
on the terminal block. Tighten both screws
securely.
WARNING
ELECTRICAL SHOCK HAZARD
7 Follow manufacturer’s guidelines for fi rmly securing
the strain relief and power cord.
8 Reinstall the terminal block cover.
If a terminal screw falls during cord installation, it can
be retrieved in the terminal screw recovery slot below
the access panel.
30 AMP
NEMA 10-30
NOTE
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
(center wire)
Access cover
(BRASS terminal)
(SILVER terminal)
(BRASS terminal)
Internal ground
(GREEN screw)
UL-approved
strain relief here
Terminal screw
recovery slot
Neutral
terminal
screw
Terminal
block
Line 2
Neutral
Line 1
Install
IMPORTANT
If moving dryer from a 4-wire system and installing it
in a 3-wire system, move the internal ground from the
center terminal back to the GREEN screw next to the
terminal block.
17
INSTALLATION INSTRUCTIONS
Neutral
(WHITE wire)
30 AMP
NEMA 14-30
Ground
(GREEN wire)
Move internal ground (WHITE)
wire to neutral (SILVER)
terminal for 4-wire system.
Neutral
terminal
GREEN
ground screw
BLACK or
RED power wire
BLACK
or RED
power wire
GREEN
ground wire
WHITE
neutral wire
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Terminal
block
Electrical connection (non-Canada) - 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
WARNING
Failure to disconnect power source before servicing
could result in personal injury or even death.
1 Turn off power supply to outlet.
2 Remove the screw securing the terminal block
3 Install a UL-approved strain relief according to the
4 Thread an UNPLUGGED, UL-approved, 30 amp.
5 Disconnect the internal (WHITE) dryer harness
6 Attach the ground (GREEN) power cord wire to the
7 Move the internal dryer harness ground (WHITE)
8 Attach the RED and BLACK power cord conductors
Do not make a sharp bend or crimp wiring/conductor
at connections.
9 Follow manufacturer’s guidelines for fi rmly securing
10 Reinstall the terminal block cover.
ELECTRICAL SHOCK HAZARD
access cover in the lower corner on the back of the
dryer.
power cord/strain relief manufacturer’s instructions
in the power cord entry hole below the access
panel. At this time, the strain relief should be
loosely in place.
power cord, NEMA 14-30 type ST or SRDT, through
the strain relief.
ground wire from the (GREEN) ground screw next
to the terminal block.
cabinet with the ground (GREEN) screw. Tighten
the screw securely.
wire to the terminal block and attach it along with
the neutral (WHITE) power cord wire conductor
to the center, SILVER colored terminal on the
terminal block. Tighten the screw securely.
to the outer, BRASS colored terminals on the
terminal block. Tighten both screws securely.
WARNING
ELECTRICAL SHOCK HAZARD
the strain relief and power cord.
NOTE
If a terminal screw falls during cord installation, it can
be retrieved in the terminal screw recovery slot below
the access panel.
Move internal ground (WHITE)
terminal for 4-wire system.
30 AMP
NEMA 14-30
wire to neutral (SILVER)
GREEN
ground screw
GREEN
ground wire
RED power wire
BLACK or
Ground
(GREEN wire)
(BRASS terminal)
(SILVER terminal)
(BRASS terminal)
Internal ground
strain relief here
Neutral
terminal
Neutral
(WHITE wire)
Access cover
screw
Terminal
block
Line 2
Neutral
Line 1
(GREEN screw)
Install
UL-approved
Terminal screw
recovery slot
WHITE
neutral wire
BLACK
or RED
power wire
18
INSTALLATION INSTRUCTIONS
Grounding type
ll receptacle
wer cord with
3-prong grgr
ounded plug
Do not,
under
y cir
cumstances,
cut,
removeve,
or b
ypass the
ounding pr
ong.
General installation
1 Connect the exhaust duct to the outside exhaust
system. Use of a 4” (102 mm) clamp (item A) is
recommended to connect the dryer to the exhaust vent
system. Use metal foil tape to seal all other joints.
2 Use a carpenter’s level to level your dryer front-to-back
and side-to-side.
3 Use adjustable pliers to adjust the leveling legs so the
dryer is level front-to-rear and side-to-side, and stable
corner-to-corner.
4 Press down on alternate corners and sides and feel for
the slightest movement. Adjust the appropriate leg(s)
so the dryer sits solidly on the fl oor on ALL four legs.
Keep the leveling leg extension at a minimum for best
performance of the dryer.
IMPORTANT
Be sure the power is off at a circuit breaker/fuse box
before plugging the power cord into an outlet.
5 Plug the power cord into a grounded outlet.
Grounding type
wawall receptacl
PoPower cord with
3-prong
Do not,
anany cir
cut,
remo
or b
ypass th
grgrounding pr
ounded plug
under
cumstances,
ong.
A
6 Turn on the power at the circuit breaker/fuse box.
7 Read the Use & Care Guide provided with the dryer. It
contains valuable and helpful information that will save
you time and money.
8 If you have any questions during initial operation,
please review the “Avoid Service Checklist” in your Use
& Care Guide before calling for service.
9 Place these instructions in a location near the dryer for
future reference.
NOTE
A wiring diagram and technical data sheet are located
under the dryer top panel.
19
REVERSING DOOR
Removing the door
1 Protect fl at work surface, such as top of dryer or
fl oor near dryer, with a soft cloth or towel.
2 Open dryer door and remove the two hinge screws.
Remove lower screw fi rst, then upper screw.
3 Supporting door with both hands, squarely lift door
and hinge upward approximately 3/8” (10 mm) so
“T” post on back of hinge can slide out through “T”
slot on front panel.
“T” SLOT IN
FRONT PANEL
“T” POST ON
DOOR HINGE
4 Gently place dryer door face down on fl at, covered
work surface.
5 Locate the 5 indented head screws (no. 1-5) in the
small, circular recesses (at 11, 1, 4, 6, and 8 o’clock
positions) of the inner door. Remove and save
these 5 screws.
IMPORTANT
Do not attempt to remove the 2 “tamper-resistant”
screws that hold the inner glass in place.
6 Locate the 2 pan head screws (no. 6-7) on the
inner door nearest the metal strike and center of
hinge (9 and 3 o’clock positions). Remove and save
these 2 screws.
7 Separate inner door assembly from outer door
assembly.
20
Reversing the hinge
1 Carefully pull out the 2 small round hole plugs from
the front panel and save. Remove and save the
square “T” slot cover by sliding it up and pulling
it out. Move all 3 plugs to the opposite side of the
front panel and insert.
ROUND PLUG
SQUARE PLUG
ROUND PLUG
2 Turn inner door assembly over to expose retaining
tabs of metal strike. Grip tabs fully with pliers to
remove. Discard old metal strike.
REVERSING DOOR
4 From the back side of the inner door, pinch the
retaining tabs of the plastic square plug to release
it. Save square plug for reinstallation.
5 Carefully remove the 2 round plugs from the inner
door and move them to the opposite holes and
reinstall.
OUT
IN
3 Turn the inner door assembly back over and locate
the 2 pan head hinge screws. Remove and save the
2 screws and separate the hinge from inner door
assembly.
HINGE SCREWS
6 Rotate the hinge and move it to the opposite side
of the inner door. Attach it with the 2 pan head
screws removed previously. Reinstall plastic plug in
the square hole next to the hinge.
21
REVERSING DOOR
Reassembling the door
1 Lift the inner glass ring. Rotate it 180 degrees,
reinstall on outer door, lining up indicators - “LH”
for left-hand hinge or “RH” for right-hand hinge.
3 Replace indented head screws (no. 1-5) removed
earlier. Take care not to strip out the plastic holes.
4 Replace pan head screws (no. 6-7) removed earlier.
Take care not to strip out the plastic holes.
2 Rest the opening of the inner door at a 90 degree
angle on the supports for the hinge cutout cover.
Pivot the inner door down onto the outer door.
no. 1-5
5 Locate new metal strike supplied with dryer
manuals. Grip new strike with pliers as shown
below. Firmly insert the strike so it is oriented
vertically.
no. 6-7
22
Reattaching the door
1 Holding the door in both hands, squarely insert
the “T” post on the back of the hinge into the “T”
slot on the front panel and lower it to align the
mounting holes.
“T” SLOT IN
“T” POST ON
DOOR HINGE
2 While supporting the door, install the upper pan
head screw fi rst and then the lower one.
FRONT PANEL
REVERSING DOOR
3 Close the door and test operation of hinge, strike
and latch.
NOTE
Correctly installed hinge screws will press hinge fl ush
to front panel. Any gap between hinge and front panel
will cause misalignment of strike to latch.
23
Loading...
+ 53 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.