Quiet Design -- does
th e sound of the co mpressor starti ng
R
ma ny
minutes s econds minutes
se conds rando m
t o help avoid powe r surges
R F P -- This protection feature will a e nsure i ndoor
emperature does not fall below freezing Wh en your PTAC (w hich is
can be switched off (please see page
9)
feature off (se e section
U
ro om temperature ri se s
Fan C for ation of Th e u
ap plication by
electric th e
ru n after the t o
Fan Motors-Perma nently Lubricate d -- The unit h av e two fan mot ors for quiet o peration and
maximum operati ng efficiency. Mo tors are perm an ently lubri cated to reduce maintenance an d totally
enclosed to kee p dirt and wa ter out of the motor windin gs .
Outdoor Fan -- The u nit automatic ally select s th e most effici ent speed for the outdoor fa n. The
operating sound level is lower when the outdoor fan can operate in low speed yet there are s ituations
where it must ope rate in high sp eed. The unit changes the fan speed aut omatically.
Indoor Fan Speed Select ions-HI GH/LOW -- The u nit automatical ly selects th e most effi ci ent speed
for the outdoor fan. The opera ting sound leve l is lower when the outdoor fan can operate in low spe ed yet
there are sit uations where i t must operate in high speed. The unit change s the fan speed automatically.
y
Total Corrosion© Protection -- All Frigidaire PTAC’s come standard with
anti-corrosion protection, to increase system and component durability in
standard applications and protect system and components in Coastal areas
where Air sea salt content is higher than standard applications. All coils are
treated with a dual hydrophilic coating, and an added hydrophilic coating for all
connecting plates. Standard materials have been replaced with stainless steel
for critical components such as hardware, condenser side panel, compressor
hardware and Condenser fan hardware. Special anti-corrosion paint is used on
the drain pan to ensure the integrity of unit mounts to the chassis.
Dry Mode -- For increased comfort and humidity management, an added “Dry Mode” is standard on all Frigidaire
PTAC’s. This mode feature will help manage and reduce the humidity content within the living space, making it more
comfortable. In DRY mode, the unit will modulate cooling mode at low fan speed until the room temperature is 4° F
below the room temperature setting regardless of fan mode selection. Dry mode should not be considered a
substitute for a standalone dehumidifier. In “dry mode” more condensation will be created and the use of a “drain kit”
(5304480570) is recommended.
This unit has many exciting features which are different from those found on
standard PTAC models. The owner must be familiar with these features in
order to fully understand the operation and capability of the unit.