Frigidaire FFRE12B3Q15, FFRE12B3Q14, FFRE12B3Q13, FFRE12B3Q12, FFRE1233Q1A5 Owner’s Manual

...
F IGIDAI E
TABLE OF CONTENTS
Important Safety Instructions .............................. 2-3 Operating Instructions ....................................... 5-10
Product Reglstrahon ........................................... 4 Care and Cleaning ........................................... 11
Packaging ....................................................... 4 Energy Saving Ideas ......................................... 11
Normal Sounds ................................................ 4 Before You Call ............................................... 12
Air CondLhoner Features ................................ 5 Major Appliance Limited Warranty ........................ 13
www fng_daire com USA 1-800-944-9044 www fng_daire ca
Canada 1-800-265-8352
o _J
c
This USE & CARE MANUAL provides specific operating instructions for your model, Use the room air conditioner only as instructed in this USE & CARE MANUAL These instructions are not meant to cover every possible condition and situation that
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance
The power supply cord with this air conditioner contains a current
detection device designed to reduce the risk other appliance. Read product ]abels for flammability and other warnings.
of fire. .................................................................................... :
Please refer to the section 'Operation of Current Device' for details.
In the event that the power supply cord is Prevent Accidents damaged, it cannot be repaired. It must be
replaced with a cord from the product To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, manufacturer, follow basic precautions, including the following:
......................................................................................... Be sure the electrical service is adequate for the model you have chosen. This information
Avoid fire hazard or electric shock. Do not sides of the glass first, if the window is a triple-track type with a screen panel included, use an extension cord or an adaptor plug. Do remove the screen completely before installation.
not remove any prong from the power cord. , Be sure the air conditioner has been securely and correctly installed according to the
Grounding type wall installation instructions for possible future use in removing or reinstalling this unit. receptacle , When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
Power supply cord receptacle you intend to use is not adequately grounded or protected by a time delay fuse with 3=prong grounding or circuit breaker, have a qualified electrician install the proper receptacle.
plug and current Do not run air conditioner without outside protective cover in place. This could result in detection device mechanical damage within the air conditioner.
........................................................................................................................... DO not use an extension cord or an adapter plug,
_iii ii
i_iii
DO not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
, grille.Canbe found on the serial plate, which is located on the side of the cabinet and behind the
If the air conditioner is to be installed in a window, you will probably want to clean both
separate installation instructions provided with this manual. Save this manual and the
plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded walt receptacle. If the wall
For Your Safety
Do not insert or place fingers or objects into the air discharge area in the front of the unit. Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.
Do not cut or damage the power cord. If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer. In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized
Electrotux servicer.
, Do not operate the air conditioner with wet hands.
Do not pull on the power cord.
Do not drink any water that is drained from the air conditioner.
2
CAUTION! Avoid Injury or damage to the unit or other property
Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively.
Do not climb on or place objects on outdoor part of the unit.
, Do not hang objects off the unit.
Do not place containers with liquids on the unit.
Turn off the air conditioner at the power source when it will not be used for an extended period of time.
Periodically check the condition of the unit's installation accessories for any damage.
Do not apply heavy pressure to the radiator fins of the unit.
Operate the unit with air filter in place. Do not block or cover the intake grille, discharge area and outlet ports.
Ensure that any electrical/electronic equipment is one yard away from the unit.
Do not use or store flammable gases near the unit.
i
READTHIS SECTION BEFOREATTEHPTING TO OPERATEAIR CONDITIONER. Unit must be upright for one hour prior to operating.
Operation of Current Device
Plug in & "'T"_ . press RESET
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1, P_ug in the Air Conditioner, 2, The power supply cord will have TWO buttons on the plug head. Press the TEST button, You will
notice a click as the RESET button pops out,
3, Press the RESET button. Again you will notice a click as the button engages, 4, The power supply cord is now supplying electricity to the unit.
, Do not use this device to turn the unit on or off. ' Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it falls to reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer. If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained from the product manufacturer.
@2009 Electrolux Home Products, inc. All rights reserved.
Product Registration Record Your Hodel and Serial Numbers
Record in the space provided below the model and serial numbers. On all models, the
serial plate is located on the outside of the cabinet,
Hodel No
Serial No
Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed and returned to the Frigidaire Company.
Packaging Remove all packaging from inside the carton, along with any
inserts placed into the side louvers.
PACI(AGTNG TNSERTS
J i
Normal Sounds
High pitched Chatter
Today's high efficiency compressors
Sound of Rushing Air At the front of the unit, you may
hear the sound of rushing air being moved by the fan,
Gurgle/Hiss /
"Gurgling or hissing" noise may be
heard due to refrigerant passing
through evaporator during normal operation.
may have a high pitched chatter during the cooling cycle,
\
\
\
\
\
J J
_lbration
Unit may vibrate and make noise because of poor wall or window
construction or incorrect installation.
"_11_1Pinging or _wi_hing
s of water hitting condenser normal operation may cause
_/ Note: Don't try to drill any holes
g or swishing" sounds.
on....th>'/ _e base pan to eliminate the
normal sounds_ otherwise it will void the warranty.