Important Safety Instructions
NOTE:
This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as
instructed in this USE & CARE MANUAL. These instructions are not meant to cover every possible condition and situation that
may occur. Common sense and caution must be practiced when installing, operating, and maintaining any appliance.
NOTE:
The power supply cord with
this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired. It must be
replaced with a cord from the product
manufacturer.
WARNING
Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.
115V
15A
230V
15A
230V
20A
Grounding Prong
Do not, under any
230V
30A
circumstances, cut,
remove or bypass the
grounding prong.
SAFETY PRECAUTIONS
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.
For Your Safety
WARNING
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following:
Be sure the electrical service is adequate for the model you have chosen. This information
can be found on the serial plate, which is located on the side of the cabinet and behind the
grille.
If the air conditioner is to be installed in a window, you will probably want to clean both
sides of the glass first. If the window is a triple-track type with a screen panel included,
remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed according to the
separate installation instructions provided with this manual. Save this manual and the
installation instructions for possible future use in removing or reinstalling this unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front
and rear coils.
Prevent Accidents
WARNING
The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,
proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.
Do not run air conditioner without outside protective cover in place. This could result in
mechanical damage within the air conditioner.
Do not use an extension cord or an adapter plug.
Electrical Information
DANGER! Avoid Serious Injury or Death
This air conditioner contains no user-serviceable parts. Always call an authorized Electrolux servicer for repairs.
Do not insert or place fingers or objects into the air discharge area in the front of the unit.
Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box.
Do not cut or damage the power cord.
If the power cord is damaged, it should only be replaced by an authorized Electrolux servicer.
In the event of a malfunction (sparks, burning smell, etc.), immediately stop the operation, disconnect the power cord, and call an authorized
Electrolux servicer.
Do not operate the air conditioner with wet hands.
Do not pull on the power cord.
Do not drink any water that is drained from the air conditioner.
2009 Electrolux Home Products, Inc.All rights reserved.
2
Important Safety Instructions
SAFETY PRECAUTIONS
CAUTION! Avoid Injury or damage to the unit or other property
Provide ventilation per installation instructions.
Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively.
Do not climb on or place objects on outdoor part of the unit.
Do not hang objects off the unit.
Do not place containers with liquids on the unit.
Turn off the air conditioner at the power source when it will not be used for an extended period of time.
Periodically check the condition of the unit’s installation accessories for any damage.
Do not apply heavy pressure to the radiator fins of the unit.
Operate the unit with air filter in place.
Do not block or cover the intake grille, discharge area and outlet ports.
Ensure that any electrical/electronic equipment is one yard away from the unit.
Do not use or store flammable gases near the unit.
Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
When cleaning the unit, first make sure that the power and circuit breaker are turned off.
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.
Unit must be upright for one hour prior to operating.
The power supply cord contains a current device that senses damage to the power cord. To test
your power supply cord do the following:
Plug in the Air Conditioner.
The power supply cord will have TWO buttons on the plug head. Press the TEST button. You will
Plug in &
press RESET
notice a click as the RESET button pops out.
Press the RESET button. Again you will notice a click as the button engages.
The power supply cord is now supplying electricity to the unit. (This is also indicated by a light
on the plug head).
NOTE:
Do not use this device to turn the unit on or off.
Always make sure the RESET button is pushed in for correct operation.
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed,
or it cannot be reset. A new one can be obtained from the product manufacturer.
If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one obtained
At the front of the unit, you may
hear the sound of rushing air
being moved by the fan.
Record Your Model and Serial Numbers
Record in the space provided below the model and serial numbers. On all models, the
serial plate is located on the outside of the cabinet.
Model No.
Serial No.
Register Your Product
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely,
signed and returned to the Frigidaire Company.
Remove all packaging from inside the carton, along with any
inserts placed into the side louvers.
Remove the plastic ties and foam pad that secure the
compressor to the fan shroud (where applicable). See diagram.
foam pad + plastic ties
Packing Inserts
High pitched Chatter
Today’s high efficiency compressors
may have a high pitched chatter
during the cooling cycle.
Vibration
Unit may vibrate and make noise
because of poor wall or window
construction or incorrect installation.
4
Gurgle/Hiss
“Gurgling or hissing” noise may be
heard due to refrigerant passing
through evaporator during normal
operation.
2009 Electrolux Home Products, I.devresersthgirllA.cn
Pinging or Swishing
Droplets of water hitting condenser
during normal operation may cause
“pinging or swishing” sounds.
Note: Don’t try to drill any holes
on the base pan to eliminate the
normal sounds, otherwise it will
void the warranty.
Air Conditioner Features & Operating Instructions
Air Conditioner Features
ECO
FEATURE
TURNS UNIT
ON OR OFF
STANDARD REMOTE
SLEEP
FEATURE
SETS MODE
WITH DISPLAY & REMOTE
SENSING BUTTON
ELECTRONIC CONTROL
Before you begin, thoroughly familiarize yourself with the control panel and remote
as shown below and all its functions, then follow the symbol for the functions you
desire. The unit can be controlled by the touch pad alone or with the remote.
DISPLAYS
TEMPERATURE/TIME
ADJUSTS
TEMPERATURE
OR TIME
Light Feature:
The display and all LED indicators on the control panel of the unit can
be turned off by pressing the "Light" button on the remote control. If
any other button of the control panel and remote control is pressed
after that, the unit will beep to indicate it works as the corresponding
direction of pressing specific button, and the display and LED
indicators will illuminate accordingly, but they will turn off again in 5
seconds if no further operation.
Press the "Light" button again or unplug the unit to cancel this setting.
Battery Size: AAA
Warning: Do not mix old and new batteries. Do not mix alkaline,
standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.
SETS
FAN SPEED
CHECK FILTER
RESET BUTTON
REMOTE TEMP
SENSING INDICATOR
(some models)
ACTIVATES
TIMER
Operating Instructions
NOTE
The following instructions represent the Touch Pad, the same instructions can be used for the Remote Control.
YOU WILL SEE:TO TURN UNIT ON:
NOTE: The unit will run in Cool mode with Eco feature
DO THIS:
PRESS ON/OFF BUTTON
and Auto fan speed setting when used for the first time.
With the Eco feature, when the room temperature is below the
set temperature, the fan will continue to run for 3 minutes after
the compressor shuts off. The fan then cycles on for 2 minutes
at 10 minute intervals until the room temperature is above the
set temperature, at which time the compressor turns back on.
Eco feature can be activated or deactivated by pressing Eco
button, but it is invalid in fan only mode.