Frigidaire FFRA082ZA1, FFRA062ZA1 Installation Manual

Installation Instructions
READ BEFORE INSTALLING UNIT
BK Window Mounting (6,000 - 8,000 BTU)
INSTALLATION WARNINGS AND CAUTION
Carefully read the installation manual before beginning.
be exposed:
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.
NOTE:
the best way to store unit during winter, or when not in use.
Top Rail Hardware
Qty.
4
Before installing, the top rail must be assembled on the unit.
Top Rail
1
Fig. B
Fig. B
Mounting Hardware Qty.
(For Wooden windows)
(For Vinyl-Clad windows)
weather seals
window sash seal foam 1
Drill (If pilot holes are needed)
Fig. C
7
2
2
1
5
66129926907
1
Installation
LEFT + RIGHT FILLER PANEL ASSEMBLY
NOTE:
Top Rail and Side Panels at each side are offset to provide the proper pitch to the rear. This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained!
Place unit on floor, a bench or a table. There is a Left and Right side Filler Panels - be sure to use the proper panel for each side. When installed, the flange for securing the panel in place to the window sill will be facing into the room.
A. Hold the side Panel in one hand and gently pull back the center to free the open end. See FIG. 1. B. Slide the free end “T” section of the panel directly into the cabinet as shown in FIG. 2. Slide the panel down. Be
sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet. C. Once the panel has been installed on the side of the cabinet, make sure it sits securely inside the frame channel by
making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. See FIG. 3.
D. Slide the panel all the way in and repeat on the other side.
FIG. 2 FIG. 3FIG. 1
“T” section
Top Rail
Cut the seal foam(adherent type) into proper length. Then stick the seal foam at the lower part of the window frame. Your air conditioner is designed to install in standard double hung windows with opening widths of 22 to 36 inches (558 mm to 914 mm) (FIG. 4A & FIG. 4B) Lower sash must open sufficiently to allow a clear vertical opening of 13.25 inches (337 mm ). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage.
Fig. 4A
INNER WINDOW SILL
INTERIOR
WALL
SEAL FOAM
22" to 36"
(558 mm to 914mm)
13.25" min (337 mm)
Wooden Windows
Fig. 4B
INNER WINDOW SILL
Storm Window:
If the air conditioner is blocked by Storm Window, add wood as shown in FIG. 5, or remove storm window before air conditioner
is installed. If Storm Window Frame must remain, be sure the drain holes or
slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out.
Storm window frame or other obstruction.
Bottom Rail
SEAL FOAM
1-1/2” min
(38 mm)
22" to 36"
(558 mm to 914mm)
13.25" min (337 mm)
Vinyl-Clad Windows
SASH
FIG. 5
Board thickness as required, for proper pitch to rear, along entire sill. Fasten with nails or screws.
2
Loading...
+ 2 hidden pages