Frigidaire FFGF3016TS, FGGF3047TF Installation manual

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE. READ AND SAVE THESE
INSTRUCTIONS FOR FUTURE REFERENCE.
Tip Over Hazard
A child or adult can tip the range
and be killed.
Verify the anti-tip device has been
installed to fl oor or wall.
Ensure the anti-tip device is re-engaged when the
range is moved to fl oor or wall.
Do not operate the range without the anti-tip device in
place and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
Range
leveling leg
To check if the anti-tip bracket is installed properly, use both arms and grasp the rear edge of range back. Carefully attempt to tilt range forward. When properly installed, the range should not tilt forward.
Refer to the anti-tip bracket installation instructions supplied with your range for proper installation.
Anti-Tip bracket
If the information in this manual is not followed exactly, a fi re or explosion may result causing property damage, personal injury or death.
Refer to your serial plate for applicable agency certifi cations
Provide proper fuel type
Before proceeding: Your range is factory preset to oper-
ate on natural gas. If L.P. conversion is needed, contact your local L.P. Gas provider for assistance.
The L.P. conversion kit may be located on the lower rear back panel of the range. If no L.P. kit is provided, contact your product dealer to obtain the correct L.P. conversion kit.
Important notes to the installer
Read all instructions contained in these installation instructions before installing range.
Remove all packing material from the oven compartments before connecting the gas and electrical supply to the range.
Observe all governing codes and ordinances.
Be sure to leave these instructions with the consumer.
FOR YOUR SAFETY: — Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re department.
— Installation and service must be performed
by a qualifi ed installer, service agency or the gas supplier.
Important notes to the consumer
Keep these instructions with your Use & Care Guide
for future reference.
Be sure your range is installed and grounded properly by a qualifi ed installer or service technician.
Special instructions for appliances installed in the State of Massachusetts:
This appliance can only be installed in the State of Massachusetts by a Massachusetts licensed plumber or gas fi tter. When using a fl exible gas connector, it must not exceed 3 feet (36 inches) in length. A “T” handle type manual gas valve must be installed in the gas supply line to this appliance.
1
316903002 Rev A (1304)
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
IMPORTANT SAFETY INSTRUCTIONS
Installation of this range must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1—latest edition when installed in the United States.
When installed in a manufactured (mobile) home, installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or with local codes.
This range has been design certifi ed by CSA International. As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will fi nd them in the Use & Care Guide, read it carefully.
Be sure your range is installed and grounded properly by a qualifi ed installer or service technician.
This range must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No .70— latest edition when installed in the United States. See Grounding Instructions on page 8.
Before installing the range in an area covered with linoleum or any other synthetic fl oor covering, make sure the fl oor covering can withstand heat at least 90°F above room temperature without shrinking, warping or discoloring. Do not install the range over carpeting unless you place an insulating pad or sheet of 1/4-inch thick plywood between the range and carpeting.
Make sure the wall coverings around the range can withstand the heat generated by the range.
Do not obstruct the fl ow of combustion air at the oven vent nor around the base or beneath the lower front panel of the range. Avoid touching the vent openings or nearby surfaces as they may become hot while the oven is in operation. This range requires fresh air for proper burner combustion.
Air curtain or other overhead range hoods, which operate by blowing a downward air fl ow on to a range, shall not be used in conjunction with gas ranges other than when the hood and range have been designed, tested and listed by an independent test laboratory for use in combination with each other.
DO NOT MAKE ANY ATTEMPT TO
OPERATE THE ELECTRIC IGNITION OVEN DURING AN ELECTRICAL POWER FAILURE. RESET ALL OVEN CONTROLS TO “OFF” IN THE EVENT OF A POWER FAILURE.
The electric ignitor will automatically re-ignite the oven burner when power resumes if the oven thermostat control was left in the “ON” position.
When an electrical power failure occurs during use, the surface burners will continue to operate.
During a power outage, the surface burners can be lit with a match. Hold a lighted match to the burner, then slowly turn the knob to the LITE position. Use extreme caution when lighting burners this way.
Never leave children alone or unattended in the area where an appliance is in use. Teach children the proper, safe use of all appliances. Never leave the oven door open when the range is unattended.
Stepping, leaning or sitting on the doors or drawers of this range can result in serious injuries and can also cause damage to the range.
Do not store items of interest to children in the
cabinets above the range. Children could be seriously burned climbing on the range to reach items.
To eliminate the need to reach over the surface
burners, cabinet storage space above the burners should be avoided.
Adjust surface burner fl ame size so it does not extend
beyond the edge of the cooking utensil. Excessive ame is hazardous.
Do not use the oven as a storage space. This creates
a potentially hazardous situation.
Never use your range for warming or heating the
room. Prolonged use of the range without adequate ventilation can be dangerous.
Do not store or use gasoline or other fl ammable
vapors and liquids near this or any other appliance. Explosions or fi res could result.
Reset all controls to the “OFF” position after using a
programmable timing operation.
Unlike some gas ranges, the cooktop is not removable.
Do not attempt to remove the cooktop.
2
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
Tools you will need
(Wear safety glasses when using tools):
For leveling legs and Anti-Tip Bracket:
Adjustable wrench or channel lock pliers (Fig. a)
5/16” Nutdriver or fl at head screwdriver (Fig. b)
Electric drill & 1/8” drill bit (3/16” Masonry drill bit if installing in concrete) (Fig. c)
Level (Fig. d)
For gas supply connection:
Adjustable wrench and pipe wrench (Figs. a & e)
For burner fl ame adjustment:
Phillips head and small fl at-blade screwdrivers (Figs. f & g)
Materials you will need:
Pipe joint sealant that resists action of LP/Propane gas (Fig. h)
Gas line manual shut-off valve (Fig. i)
• A new fl exible metal appliance conduit (1/2” NPT x 3/4” or 1/2” I.D.) must be design certifi ed by CSA International. Because solid pipe restricts moving the range, we recommend using a new fl exible conduit (4 to 5 foot length) for each new installation and additional reinstallations. (Fig. j)
• Use new fl are union adapters (1/2” NPT x 3/4” or 1/2” I.D.) (Fig. k)
Tools
Fig. a
Fig. b
Materials
Fig. e
Fig. f
Fig. g
Fig. c
Fig. d
Fig. h
Fig. k
Materials supplied with appliance:
Anti-Tip Template (Fig. l)
• Anti-Tip bracket; includes 2 mounting screws (Fig. m)
Fig. i
Fig. j
Materials supplied with appliance
Fig. l
Fig. m
3
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
Installation with cabinets
Check location where the range will be installed for proper electric and gas supply, and stability of the fl oor.
The dimensions shown here must be used and are minimal unless otherwise stated. These measurements do not allow for any clearance below the cooking top or at the rear of the range.
Contact surface must be solid and level.
Things to remember:
Do not seal the range to side cabinets.
Do not pinch the power supply cord between the range and rear wall.
If cabinet depth is greater than 25”, the oven front frame must extend beyond cabinet front by 1/2” minimum (See Fig. 1).
All openings in the wall or oor where the range is to be installed must be sealed.
Installation beside wall
If installing beside a wall, the minimum distance to combustible wall on either side of range above 36” height should be according to the BTU of the largest burner (See Fig 2).
36”
Std.
13”
18”
Min. to cabinets on
either side of range
Recommended area for thru the fl oor connection of gas pipe stub and shut-off valve.
Max.
30”
cooktop to cabinets
*15”
* Models without self-clean feature may have an additional 7 inches clearance from the fl oor.
30”
Min. height from
30”
11-1/2”
23”
10-1/2”
2”
7”
Fig. 1
25”
24”
Recommended area for 120V outlet on rear of wall and area for thru the wall connection of pipe stub and shut­off valve.
30”
*
* 9500 BTU or less 2” 10,000 - 16,999 BTU 3” 17,000 BTU or greater 5”
Fig. 2
4
36±1/8”
(Adjustable)
25-3/4”
48-1/2” max
29-1/4”
max
door
closed
46-5/8”
max
door
open
29-7/8”
Fig. 3
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
Install anti-tip bracket
1
IMPORTANT SAFETY WARNING!
To reduce the risk of tipping of the range, the range must be secured to the fl oor by properly installed an- ti-tip bracket and screws packed with the range. Fail­ure to install the anti-tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it. Serious injury might result from spilled hot liquids or from the range itself.
If range is ever moved to a different location, the anti-tip bracket must also be moved and installed with the range.
Instructions are provided for installation in wood or cement fastened to either the fl oor or wall. When installed to the wall, make sure that screws completely penetrate dry wall and are secured in wood or met­al. When fastening to the fl oor or wall, be sure that screws do not penetrate electrical wiring or plumbing.
Anti-tip bracket installation instructions
a. Locate the bracket using the template - (Bracket
may be positioned on either the left or right side of the range. Refer to Figs. 4, 5, & 7 to position the bracket if template is not available).
Mark the fl oor or wall where left or right side of the
range will be located. If rear of range is against wall or no further than 1-1/4” from wall when installed, you may use the wall or fl oor mount method. If molding is installed and does not allow the bracket to fi t fl ush against wall, remove molding or mount bracket to fl oor.
For wall mount (Fig. 4), locate the bracket by placing
the back edge of the template against rear wall and the side edge of template on the mark made referencing the side of the range. Place bracket on top of template and mark location of the screw holes in wall. If rear of range is further than 1-1/4” from wall when installed, attach bracket to the fl oor (See Fig. 5).
Fig. 5
For fl oor mount, locate the bracket by placing back
edge of the template where the rear of the range will be located. Mark the location of the screw holes shown in template.
b. Drill pilot holes & fasten bracket - Drill 1/8” pilot hole
where screws are to be located (Fig. 6). If bracket is to be mounted to the wall, drill pilot hole at an approximate 20° downward angle. If bracket is to be mounted to masonry or ceramic fl oors, drill 3/16” pilot hole 1-3/4” deep. The screws provided may be used in wood or concrete material. Use 5/16” nut-driver or fl at head screwdriver to secure the bracket in place.
c. Level & position range - Level range by adjusting the
(4) leveling legs with a wrench.
Note: A min. clearance of 1/8” is required between bottom
of range and leveling legs to allow room for bracket.
Slide range back into position (Fig. 7). Remove lower
panel or storage drawer to visually check that rear leveling leg is inserted into and fully secured by the bracket. For models with a warmer drawer or broiler compartment, grasp the top rear edge of the range and carefully attempt to tilt it forward.
Fig. 6
Fig. 4
5
Fig. 7
INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
Provide an adequate gas supply.
2
Please note: Operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above sea level.
This appliance is pre-set to operate on 4” natural gas manifold pressure. A convertible pressure regulator is connected to the manifold and MUST be connected in series with the gas supply line. If the LP/Propane conversion kit has been used, follow instructions provided with the kit for converting the pressure regulator to LP/ Propane use.
Care must be taken during installation of range not to obstruct the fl ow of combustion and ventilation air.
For proper operation, the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure. The inlet pressure to the regulator must be at least 1 inch greater than regulator manifold pressure.
Example: If regulator is set for natural gas 4 inch manifold pressure, inlet pressure must be at least 5 inches; if regulator has been converted for LP/Propane gas 10 inch manifold pressure, inlet pressure must be at least 11 inches.
Leak testing of the appliance shall be conducted according to the instructions in step 4g.
The gas supply line should be 1/2” or 3/4” I.D.
Seal wall openings.
3
Connect range to gas supply.
4
Note: To prevent leaks use pipe joint sealant on all male
(outside) pipe threads. Do not allow gas pressure regulator to turn on pipe when tightening fi ttings.
a. Install an external manual gas shut-off valve to gas
supply line in an accessible location outside of range. Be sure you know where and how to shut off the gas supply to the range (See Fig. 8).
b. Install 1/2” fl are union adapter to gas pressure
regulator using no more than 15ft./lbs. of torque (Refer to Fig. 8).
Pressure regulator
Flare
union
adaptor
Flexible appliance
conduit
Flare
union
adaptor
Manual
shut-off
valve
Seal any openings in the wall behind the range and in the oor under the range after gas supply line is installed.
Fig. 8 - gas supply connections
Be sure to stabilize the left side of the gas pressure
regulator before tightening ANY fi ttings to the pressure regulator. Do not allow pressure regulator to turn on pipe when tightening fi ttings (Refer to Fig. 9).
Fig. 9